Tektronix RMB2040 User manual

xx
RMB2040
ZZZ
Rackmount Kit
Installation Instructions
www.tek.com
P075109901*
*
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 5 0 0 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worldwide, visit www.tek.com to find contacts in your area.
Service safety summary
Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary in the product service manual or the instru
Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
To prevent the instrument and rack from falling on the operator, two or more installers should install the instrument into the rack cabinet. After completing the installation procedure, the installers should verify that the instrumentandrack cabinet
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
UseCareWhenServicingWithPowerOn. Dangerousvoltagesorcurrentsmay
in this product. Disconnect power and disconnect test leads before removing
exist protective panels, soldering, or replacing components.
To av
ction manual.
will not tip forward while the instrument is in the extended position.
oid electric shock, do not touch exposed connections.
RMB2040 Rackmount Kit Installation Instructions 1
Kit description
Kit description
Products
These instructions describe the installation of the rackmount kit to your standard bench-top instrument. The rackmount kit is a collection of parts that, once installed, c
onfigure the instrument for mounting in a fixed position into a standard
19-inch equipment rack.
TBS2xx4 Series AllSerialNumbers
Kit parts list
Table 1: RMB2040 Rackmount Kit
Item Quanti
1 2 367-0
2 1 each 426-2652-00
3 1 each 407-6072-00
41each407
5
6 1 each 407-6035-00
7
8 1 each 407-6071-00
ty
1 each 075-1099-00
1 each 407-6066-00
each
1
mber
Part nu
450-00
-6034-00
07-6033-00
4
TBS2xx4B S
The foll
Descri
TECH MANUAL: INSTRUCTIONS, THIS DOCUMENT
HANDLE, BOW; CARRYING
FACE
BRACKET, LEFT SIDE
BRACKET, REAR FEET
BR
BRACKET, TOP
BRACKET, BOTTOM
RACKET, RIGHT SIDE
B
eries AllSerialNumbers
owing table and figure show the parts list of the rackmount kit.
ption
PLATE, LEFT
ACKET, TOP HOLDER
9 1 each 426-2651-00
14 211-1275-00
FACEPLATE, RIGHT
SCREW, MACHINE, 6-32 X312 PANHEAD T15, WITH THREAD LOCKING PATCH
2 RMB2040 Rackmount Kit Installation Instructions
Table 1: RMB2040 Rackmount Kit, (cont.)
Item Quantity Part number Description
Kit description
10
11 1 pair 351-1095-00
1 each 016-2006-00 KIT, HARDWARE
4 210-0833-00
4 210-1061-00
4 210-1546-00
4 210-1547-00
4 210-1548-00
14 211-0507-00
4 211-0538-00
4 211-1218-00
4 211-1219-00
4 212-0591-00
4 212-0043-00
4 213-0199-00
WASHER, RECESSED; 0.42 ID X 0.112 THK, STL NI PLATED, 0.588 OD
WASHER, FLAT; 0.203 ID X 0.625 OD X 0.062, ZINC PLATED STEEL
SCREW, MACHINE, PANHEAD 8-32 X .500, PHILLIPS
WASHER, LOCK NO. 8, SPLIT, .040 THICK
WASHER, FLAT 12 OD X 6.4 ID X 1.6 THK
SCREW, MACHINE; 6-32 X 0.312, PNH, STEE L, ZINC PLATE, T15 TORX
SCREW, MACHINE; 6-32 X 0.312, FLH, 100 DEG, ZINC PLATED STEEL, T10 TORX
SCREW, M6 X 16MM OVAL HEAD, PHILLIPS
SCREW, M5 X 16MM OVAL HEAD, PHILLIPS
SCREW, MACHINE; 10-32 X .750 OVAL HEAD, POZI
SCREW, MACHINE; 8-32 X 0.5, FLH, 100 DEG, STL CD PL, POZ
SCREW, MACHINE; 12-24 X 0.75, OVH, STL NP, POZ
SLIDE ASSY; PAIR, W/STD HARDWARE KIT AND REAR BRACKET
Figure 1: Rackmount kit parts (part appearance may vary)
RMB2040 Rackmount Kit Installation Instructions 3
Kit description
Table 2: Option
Item Quantity Part number Description
1 1 pair 351-1095-00
al accessories (must be ordered separately)
SLIDE ASSY; PAIR, W/STD HARDWARE KIT AND REAR BRACKET
Figure 2: Optional accessories
NOTE. The rack slides are not part of this kit. They are optional, and must be
ordered separately.
Environmental requirements
The fo specifications and performance verification sections of the manual for your instrument.
Table 3: Warranted characteristics
Characteristic Description
Temperature
Operating 0 °C to +50 °C (+32 °F to 122 °F)
Nonoperating
Humidity
Operating High: +30 °C to +50 °C, 5% to 60% relative humidity
Nonoperating
llowing environmental characteristics supersede those listed in the
–40 °C to +71 °C (–40 °F to 160 °F)
Low: 0 °C to +30 °C, 5% to 95% relative humidity
High: +30 °C to +55 °C, 5% to 60% relative humidity
Low: 0 °C to +30 °C, 5% to 95% relative humidity
4 RMB2040 Rackmount Kit Installation Instructions
Kit description
Clearance req
uirements
The rack in which the rack adapted instrument is mounted must provide the following clearance requirements:
At least 219.71 mm (8.65 in) of vertical space
A minimum width of 488 mm (19.2 in) between the left- and right-front rails in the rack. If possible, consider allowing at least 50.8 mm (2.0 in) on the right side and rear of the instrument for adequate airflow.
A minimum inside depth of at least 284.23 mm (11.19 in) depth (from rack mounting ear to back of instrument)
CAUTION.
instrument with enough clearance for air circulation and accommodation of the power cord and mounting hardware. Failure to provide these clearances can result in overheating and can cause instrument faults or failure.
Adhering to these clearance requirements provides the rack-mounted
Figure 3: Instrument with rack adapter installed
RMB2040 Rackmount Kit Installation Instructions 5
Installation instructions
Installation instructions
This section contains the procedures needed to rackmount a TBS2xx4 or a TBS2xx4B series instrument.
Minimum tool and equipment list
The following tools are required to attach the rack-adapter kit hardware, install cabling har equipment cabinet. All tools are standard tools that are readily available.
Table 4: Tools required for rackmount installation
Name Description
Screwdriver handle (magnetic)
No. 2 Phillips or PoziDriv tip
Straight tip Straight screwdriver tip for slotted screw heads
1/4 inch wrench
Torque driver
dware, and mount the rack-adapted instrument into a standard
Accepts 1/4-inch hexagonal head driver tips
Phillips or PoziDriv-driver tip for number 2 size screw heads
Wrench or nut driver is used to install slides
6.5 in long shaft; accepts 1/4-inch hexagonal head driver tips
6 RMB2040 Rackmount Kit Installation Instructions
Install the oscilloscope in the rackmount
This section describes mounting the rackmount parts to the instrument.
1. Install the left and right side brackets to the bottom bracket using three pan head screws (211-1275-00) on each side. Tighten these screws to 8 in-lb. (See Figure 4.)
Installation instructions
Figure 4: Assembling the left and right mounting plates
RMB2040 Rackmount Kit Installation Instructions 7
Installation instructions
2. Install the rea (211-1275-00), tightened to 8 in-lb. (See Figure 5.)
3. Place the righ two of the flat head screws (212-0043-00), tightened to 16 in-lb. Installingthe handle secures the faceplate in place. (See Figure 5.)
4. Repeat Step 3, using the left faceplate and handle. (See Figure 5.)
r feet bracket on the bottom bracket using two pan head screws
t faceplate into position, and then install the right handle using
Figure 5: Installing the faceplates and feet bracket
8 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
5. Place the oscil rear feet against the rear feet bracket. The front of the oscilloscope will extend slightly beyond the two faceplates. (See Figure 6.)
6. Install top holder into top bracket with two flat head screws (211-0538-00). (See Figure 6.)
7. Install the top bracket by sliding it into place from the back. Make sure the vertical side of top holder inserts into the gap, which is formed by the rear case and black rubber of handle. (See Figure 6.)
8. Attach the top bracket to the side brackets with two pan head (211-1275-00) on each side. (See Figure 6.)
loscope into the rackmount frame. Position the oscilloscope’s
Figure 6: Installing the instrument in the enclosure
RMB2040 Rackmount Kit Installation Instructions 9
Installation instructions
Rackmount the oscilloscope without rack slides
If you did not order the optional rackmount slides, you may install the oscilloscope into an equipment rack by following this procedure:
WARNING. To prevent the instrument from tipping or falling on the installers, this
procedure should be performed by two or more people.
1. Select the appropriate screws for your equipment rack from the kit; 10–32, 12–24, M5, or M6. Assemble them with the recessed and flat washers as shown:
Figure 7: Rackmount hardware
2. Standard equipment racks use one of two mounting hole spacing methods. Both methods use mounting holes spaced 0.5 inch apart, separated by a
1.25 inch gap. One method (A) places an additional mounting hole in the
e of the 1.25 inch gap (at 0.625, or 5/8, inch); the other method (B) does
middl not. (See Figure 8.)
3. Sele
4. Slide the oscilloscope into the equipment rack so that the pin extending back
ct two 0.5 inch-spaced holes in the front rail. Verify that there are clearances of 1.5 inch above the upper mounting hole and 5.50 inch below the lower mounting hole. (See Figure 8.)
from the left side, just below the upper mounting hole, goes into the lower of the 0.5 inch-spaced holes in the front rail. This pin is a locating guide, and also an aid to holding the oscilloscope in place while securing the oscilloscope to the instrument rack. (See Figure 8.)
10 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
5. Use the screws a instrument rack.
nd washers from step 1 to attach the oscilloscope to the
Figure 8: Standard rack hole spacing
RMB2040 Rackmount Kit Installation Instructions 11
Installation instructions
Rackmount the oscilloscope using optional rack slides
If you ordered the optional rackmount slides, this procedure assembles and installs the slide-out tracks in the equipment rack, and then installs the oscilloscope in the rack.
The slide-out tracks permit the oscilloscope to be extended out of the rack for rear-panel and connector maintenance without removing the instrument from the rack.
Install track assembly
WARNING. T
operator, install the instrument so that the operator is able to access all of its rear devices without pushing down on the instrument.
Verify that the rack does not become unstable with the instrument fully extended. Do not leave the instrument extended when nished accessing the rear panel.
NOTE. The r ack hardware kit contains hardware for mounting the instrument in
several congurations. Not all of the hardware in the kit is needed.
1. Remove the front (chassis) section of each of the two tracks.
o prevent the rackmounted instrument from tipping forward on the
Figure 9: Removing front track section
12 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
2. Install the lef 10-32 x 3/8 inch slotted screws. Tighten to 28 in-lb.
t and right side track sections on the instrument using six of the
Figure
10: Installing the left and right side track sections
RMB2040 Rackmount Kit Installation Instructions 13
Installation instructions
WARNING. To be sure that the rackmount track l ocks, make sure the track button
latches are or of the rackmount panel and the left-side latch is located toward the top of the rackmount panel. If the button latches are not oriented correctly the instrument could slide from the rack, which could cause personal injury or damage to the instrument.
iented correctly: the right-side latch is located toward the bottom
Figure 11: Track orientation
14 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
Assemble the slide-out
track
1. Measure the dis
2. Align the rear bracket to the right slide-out track as shown.
NOTE. The rea
aligning the bracket and track, be sure to select a pair of holes that mount the rear bracket so that the ange-to-ange distance matches the distance between the front rail and rear rail measured in step 1.
3. Using a screwdriver with a number two Pozidriv tip, attach the rear bracket to the right slide-out track using two screws (10-32) and a bar nut as illustrated. Leave the screws loose to adjust the overall length of the slide-out track assembly when installing it in the rack.
4. Step-Repeat steps 2 and 3 to assemble the left slide-out track assembly.
tance between the front and rear rail of the equipment rack.
r bracket has multiple pairs of mount-through holes. When
Figure 12: Slide track assembly
RMB2040 Rackmount Kit Installation Instructions 15
Installation instructions
Mount the slide-out track
assemblies
1. Select the moun the front rail, and verify that there is a 3.25 inch clearance above and below those mounting holes.
ting position in the rack. Select two 0.5 inch-spaced holes in
Figure 13: Rackmount positions
16 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
2. Select the moun
To mount the slide-out tracks with their front and rear flanges outside the
front and rear installation only if the rails have untapped holes.
To mount wit
method B. This mounting method assumes untapped holes.
ting method according to the rack type:
rails, use the mounting method A. Add a bar nut to the
h front and rear flanges inside the rails, use the mounting
Figure 14: Installation of slide-out track assemblies in rack (top view)
RMB2040 Rackmount Kit Installation Instructions 17
Installation instructions
3. Install in rack
Using the method and hardware determined in step 2, attach the right
slide-out tra fully, but lightly, seated so that you can adjust the hardware later.
4. Fix the leng
Tighten the screws left loose (step 3 in Assemble the slide-out track
section) to track assembly.
5. To mount th left slide-out track assembly.
:
ck assembly to its front and rear rails. The screws should be
th of the slide-out track assembly:
28 inch-lb, to fix the front to rear flange spacing of the slide-out
e left slide-out track assembly, repeat steps 3 and 4 to mount the
Figure 15: Installing the slide-out track to mount stand
18 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
Mount the oscilloscope
into the rack
Use the followi
WAR NI NG . To prevent the instrument from tipping or falling on the installers, two
or more people should install this instrument into the rack cabinet.
After completing the installation procedure, the installers should verify that the instrument and r ack cabinet will not tip forward while the instrument is in the extended pos
1. Install the instrument:
a. Working from the front of the rack, slide the inner track of each slide-out
track assembly until it extends out the front of the rack. Continue to slide them out until they lock.
b. Insert the left and right tracks that extend from the rear of the instrument
into the ends of the tracks just extended. Make sure the tracks mounted on the in
c. Slide the instrument backward until it stops.
d. Push to release the button latches, located outside of each track, and
continue to slide the instrument all the way into the cabinet.
ng instructions to install and secure instrument into the rack.
ition.
strument slip inside the inner tracks extended earlier.
2. Level the rackmounted instrument:
a. Tighten the four screws that were left loose at the rear of the rack (step
3inAssemble the slide-out track section), and then pull the instrument part way out of the rack.
b. Be sure that the four screws that were left loose at the front of the rack
are loose enough to allow the slide-out track assemblies to seek their
mal positions.
nor
c. Retighten the four screws and push the instrument all the way into the
ck. If the tracks do not slide smoothly, readjust the level using the
ra method just detailed.
hen leveling is completed, tighten the 10-32 screws using 28 inch-lb of
d.W
torque.
RMB2040 Rackmount Kit Installation Instructions 19
Installation instructions
3. Attach the inst
a. Select four of the appropriate screws for your equipment rack from the
kit; 10-32, 12
b. Attach the instrument in the rack using the screws selected, with the
recessed wa
rument to the rack:
-24, M5, or M6.
shers and flat washers.
Figure 16: Securing the instrument to mount stand
NING. To prevent the rackmounted instrument from sliding forward and
WAR
causing personal injury or instrument damage, always attach the instrument to the rack if the rack is moved (for example, if the rack is repositioned or relocated to another room)
20 RMB2040 Rackmount Kit Installation Instructions
Installation instructions
Mounting optional
accessories
The bottom brac Tek-USB-488 to USA adapter mounted to the back support. Optional accessories may be mounted with screws or nylon straps to attach them.
ket has holes for mounting optional accessories. For example,
Figure 17: Mounting optional accessories to bottom bracket
RMB2040 Rackmount Kit Installation Instructions 21