Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14200 SW Karl Braun Drive
P.O. Box 5 0 0
Beaverto
USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200.
Worl dwid e, visi t www.tektronix.com to find contacts in your area.
MTM400A and RFM300 Declassification and Security Instructionsi
Table of Contents
iiMTM400A and RFM300 Declassi fi cation and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove
memory devices from the MTM400A and RFM300 DTV Monitors.
These products have data storage (memory) devices and data output devices (USB
ports). These instructions tell how to clear or sanitize the memory devices and
disable the data output devices. The instructions also tell how to declassify an
instrument that is not functioning.
Supported Products
Related Documents
Terms
MTM400A and RFM300 DTV Monitors.
The MTM400A and RFM300 DTV Monitors Technical Reference, Tektronix
part number 077-0175-xx, is available on the Tektronix Web site at
www.tektronix.com/manuals.
The following terms may be used in this document:
Clear. This removes data o n media/memory before reusing it in a secured area.
All reusable memory is cleared to deny access to previously stored information
by standard means of access.
Erase. This is equivalent to clear.
Media storage/data export device. This refers to any of several devices that can be
used to store or export data from the instrument, such as a USB port.
Nonvolatile memory. Data is retained when the instrument is powered off.
Power off. Some instruments have a “Standby” mode, in which power is still
supplied to the instrument. For the purpose of clearing data, putting the instrument
in Standby mode does not qualify as powering off. For these products, you will
need to either press a rear-panel OFF switch or remove the power source from
the instrument.
Remove. This is a physical means to clear the d ata by removing the memory
device from the instrument. Instructions are available in the product Service
Manual.
Sanitize. This eradicates the data from media/memory so that the data cannot be
recovered by other means or technology. This is typically used when the device
will be moved (temporarily or permanently) from a secured area to a non-secured
area.
Scrub. This is equivalent to sanitize.
MTM400A and RFM300 Declassification and Security Instructions1
Preface
User-modifiabl
instrument operation, using the instrument interface or remote control.
Volatile memory. Data is lost when the instrument is powered off.
e. The user can write to the memory device during normal
2MTM400A and RFM300 Declassification and Security Instructions
Clear and Sanitize Procedures
Clear and Sani
tize Procedures
Memory Devices
Table 1: Volatile memory devices
Type and User
inputFunction
RAM
256 MB
DDR RAM 256
MB
S DRAM
128 MB
SRAM
1152 KB
CAM
288 KB
RAM
256 MB
Microprocessor
system memory
Transport traffic
queue
Microprocessor
system memory
Microprocessor
system memory
IP Traffic buffer
Microprocessor
system memory
modifiable?
The following tables list the volatile and nonvolatile memory devices in the
standard instrument and listed options. Detailed procedures to clear or sanitize
these devic
User
NoWritten by
NoWritten by
NoWritten by
NoWritten by
NoWritten by
NoWritten by
es, if any, are shown following eac h table.
Data input
method
processor
system
FPGA
processor
system
processor
system
FPGA
processor
system
Location in
instrumentTo clearTo sanitize
Power PC
board
GigE card
GigE card
GigE card
GigE card
RF interface
cards
Remove the power
source from the
instrument for at
least 20 seconds.
Remove the power
source from the
instrument for at
least 20 seconds.
Remove the power
source from the
instrument for at
least 20 seconds.
Remove the power
source from the
instrument for at
least 20 seconds.
Remove the power
source from the
instrument for at
least 20 seconds.
Remove the power
source from the
instrument for at
least 20 seconds.
N/A
N/A
N/A
N/A
N/A
N/A
Table 2: Nonvolatile memory devices
Type and User
ut
inp
RAM
NV
ction
Fun
Stores
instrument user
nfiguration
co
mod
User
ifiable?
s
Ye
Data input
hod
met
ading
Lo
configuration
file or by
ing the user
us
interface
Location in
trument
ins
ocessor card
Pr
To c
N/A
lear
anitize
To s
move power
Re
and press NV
clear button for
seconds.
10
MTM400A and RFM300 Declassification and Security Instructions3
Clear and Sanitize Procedures
Table 2: Nonvolatile memory devices, (cont.)
Type and User
inputFunction
Flash
6Mx8bits
Flash
16 M x 8 bits
Flash
8Mx8bits
Holds
instrument
firmware, MAC,
IP, Serial
and License
numbers
Holds card
firmware
and IGMP
subscription
details
Holds FPGA
image
Clear NVRAM
User
modifiable?
YesFirmw are
YesUser input
YesUser input
Data input
method
operations and
user input
Location in
instrumentTo clearTo sanitize
Processor card
GigE interface
card
GigE interface
card
N/A
N/A
N/A
Return the
instrument to
Tektronix.
Return the
instrument to
Tektronix.
Return the
instrument to
Tektronix.
Use the following procedure to clear the nonvolatile RAM:
1. Remove power.
2. Remove the top cover.
3. Push the NVRAM cle ar button on the monitor’s Processor card for 10 seconds.
4. Replace the cover.
NOTE. Removing the top cover of the instrument and accessing the NVRAM clear
button are described in the MTM400A and RFM300 DTV Monitors Technical
Reference (Tektronix part number: 077-0175-xx).
Data Export Devices
e following table lists the data export devices in the standard instrument and
Th
listed options:
Table 3: Media storage / data export disable
Type and minimum
ize
s
LAN Ethernet connector
LAN Ethernet connector
ASI/SMPTE In/Out
connectors
unction
F
Transfer dataN/AN/A
Transfer dataN/AN/AGbE interface cardN/A
Transfer dataN/AN/A
odifiable?Data input methodLocation in instrument
m
User
Processor card
Processor card
Process to
isable
d
N/A
N/A
4MTM400A and RFM300 Declassification and Security Instructions
Table 3: Media storage / data export disable, (cont.)
Troubleshooting
Type and minimum
sizeFunction
ASI/SMPTE In/Out
connectors
RF input/output
connectors
Transfer dataN/AN/AInterface cards (all)N/A
Transfer dataN/AN/ARF Interface cards (QAM BII, 8VSB,
User
modifiable? Datainput method Location in instrument
8PSK, COFDM)
Troubleshooting
How to Clear or Sanitize a Non-Functional Instrument
If your instrument is not functioning and you need to clear or sanitize it, proceed
as follows:
Main Processor Card
Remov
The MAC and IP addresses are held in an EPROM. If this needs to be sanitized,
the instrument m ust be returned to Tektronix.
NOTE. Removing the instrument’s top cover and access to the battery are
described in the MTM400A and RFM300 DTV Monitors Technical Reference,
(Tektronix part number: 077-0175-xx).
e power and remove battery; t his will clear any configuration information.
Process to
disable
N/A
abyte Ethernet
Gig
Interface Card
RF Interface Cards
This card uses data which is stored on the Main Processor card. Clearing the Main
Processor card clears all data associated with the Gigabit Ethernet card.
The RF interface cards store immediate values in memory, for example, current
frequency. These values are lost when power is removed.
How to Recover from Clearing or Removing the Instrument Memory
Follow the procedures in the MTM400A and RFM300 DTV Monitors Quick
Start User Manual to set the network, time, and license information, and then
reconfigure tests to your application.