tional copyright laws and international treaty provisions.
Tektronix pro
previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
ducts are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to find contacts in your area.
Warranty
Tektronix warrants that the product will be free from defects in materials and workmanship for a period of three (3) years from the date
of original purchase from an authorized Tektronix distributor. If the product proves defective during this warranty period, Tektronix, at its
option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the
defective product. Batteries are excluded from this warranty. Parts, modules and replacement products used by Tektronix for warranty
work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain s ervice under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty
period and make suitable arrangements for the performance of s ervice. Customer shall be responsible for packaging and shipping
the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of
purchase. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which
the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other
charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and
care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from a ttempts by personnel
other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or
connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or
d) to service a product that has been modified or integrated with other products when the effect of such modification or integration
increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTH ER WARRANTIES,
EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS
IS THE SOLE AND E XCLU S IVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRO NIX
AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES.
el at a Glance ..........................................................................................................9
Table of Content
s
PWS2185, PWS2323, PWS2326, and PWS2721 User Manuali
Table of Content
s
iiPWS2185, PWS2323, PWS2326, and PWS2721 User Manual
General Safety S
ummary
General Safet
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
To Avoid Fire or Personal Injury
Use proper power cord. Use only the power cord specified for this product and certified for the country of use.
Use proper voltage setting. Before applying power, ensure that the line selector is in the proper position for the
source being used.
Ground the product. This product is grounded through the grounding conductor of the power cord. To avoid electric
shock, the
terminals of the product, ensure that the product is properly grounded.
Observe all terminal ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the
product manual for further ratings information before making connections to the product.
Power disconnect. The power switch disconnects the product from the power source. See instructions for the location.
Do not bl
Do not op
grounding conductor must be connected to earth ground. Before making connections to the input or output
ock the power switch; it must remain accessible to the user at all times.
erate without covers.
y Summary
Do not operate this product with covers or panels removed.
Do not op
qualified service personnel.
erate with suspected failures.
If you suspect that there is damage to this product, have it inspected by
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
Use proper fuse. Use only the fuse type and rating specified for this product.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Provide proper ventilation.
proper ventilation.
Refer to the manual’s installation instructions for details on installing the product so it has
PWS2185, PWS2323, PWS2326, and PWS2721 User Manualiii
General Safety S
Terms in This Manual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Symbols and Terms on the Product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
ummary
ivPWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Compliance Info
rmation
Compliance In
This section lists the EMC (electromagnetic compliance), safety, and environmental standards with which the instrument
complies.
EMC Compliance
EC Declarati
Meets intent of Directive 2004/108/EC for Electromagnetic Compatibility. Compliance was demonstrated to the following
specifications as listed in the Official Journal of the European Communities:
EN 61326-1 2006. EMC requirements for electrical equipment for m easurement, control, and laboratory use.
CISPR 11:2003. Radiated and conducted emissions, Group 1, Class A
IEC 61000-4-4:2004. Electrical fast transient / burst immunity
IEC 61000-4-5:2001. Power line surge immunity
IEC 61000-4-6:2003. Conducted R F immunity
IEC 61000-4-11:2004. Voltage dips and interruptions immunity
on of Conformity – EMC
formation
123
4
EN 61000-3-2:2006. AC power line harmonic emissions
EN 61000-3-3:1995. Voltage changes, fluctuations, and flicker
European contact.
Tektronix UK, Ltd.
Western Peninsula
Western Road
Bracknell, RG12 1RF
United Kingdom
1
This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2
Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object.
3
For compliance with the EMC standards listed here, high quality shielded interface cables should be used.
4
Output voltage, current limit, and output state upon restoration of AC input power after a power interruption are determined by user
preference settings. Under the factory default settings, output voltage and current limit values will be restored to the previous
settings, but output state will be set to off. Change the user preferences if restoration of previous output state upon restoration of
AC input power is desired.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manualv
Compliance Info
Australia / New Zealand Declaration of Conformity – EMC
Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA:
CISPR 11:2003. Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1:2006.
rmation
Australia / Ne
Baker & McKen
Level 27, AMP Centre
50 Bridge Street
Sydney NSW 2
w Zealand contact.
zie
000, Australia
viPWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Safety Compliance
EC Declaration of Conformity – L ow Voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities:
Low Voltage Directive 2006/95/EC.
EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use.
Compliance Info
rmation
U.S. Nation
UL 61010-1:2004, 2ndEdition. Standard for electrical measuring and test equipment.
ally Recognized Testing Laboratory Listing
Canadian Certification
CAN/CSAlaboratory use. Part 1.
C22.2 No. 61010-1:2004. Safety requirements for electrical equipment for measurement, control, and
Additional Compliances
IEC 61010-1: 2001. Safety requirements for electrical equipment for measurement, control, and laboratory use.
Equipment Type
Test and measuring equipment.
y Class
Safet
Class 1 – grounded product.
Pollution Degree Description
asure of the contaminants that could occur in the environ ment around and within a product. Typically the internal
Ame
environment inside a product is considered to be the same as the external. Products should be used only in the environment
for which they are rated.
Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally
capsulated, hermetically sealed, or located in clean rooms.
en
llution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is
Po
caused by condensation must be expected. This location is a typical office/home environment. Temporary condensation
occurs only when the product is out of service.
Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation.
hese are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct
T
sunshine, rain, or direct wind.
Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical
outdoor locations.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manualvii
Compliance Info
Pollution Degree
Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only.
Installation (Overvoltage) Category Descriptions
Terminals on this product may have different installation (overvoltage) category designations. The installation categories are:
Measurement Category IV. For measurements perfo rmed at the source of low-voltage installation.
Measurement Category III. For measurements performed in the building installation.
Measurement Category II. For measurements performed on circuits directly connected to the low-voltage installation.
Measurement Category I. For measurements performed on circuits not directly connected to MAINS.
rmation
Overvolta
Overvoltage Category II (as defined in IEC 61010-1)
ge Category
viiiPWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Environmental Considerations
This section provides information about the environmental impact of the product.
Product End-of-Life Handling
Observe the following guidelines when recycling an instrument or component:
Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment
may contain substances that could be harmful to the environment or human health if improperly handled at the product’s
end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we
encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused
or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according
to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and
batteries. For information about recycling options, check the Support/Service section of the Tektronix Web
site (www.tektronix.com).
Restriction of Hazardous Substances
Compliance Info
rmation
This product is classifi ed as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manualix
Preface
Preface
Key Features
The PWS2000 Series offer:
Single-output, DC power
3-year warranty
Linear regulation
0.05% Basic voltage accuracy
0.2% Basic current accuracy
Less than 3 mVppripple and noise
20 user-defined setup memories
ModelDescription
PWS2185DC power supply. 18 V, 5 A, 1 channel
PWS2323DC power supply. 32 V, 3 A, 1 channel
PWS2326DC power supply. 32 V, 6 A, 1 channel
PWS2721DC power supply. 72 V, 1.5 A, 1 channel
xPWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Getting Started
Getting Start
ed
Standard Accessories
Accessory
PWS2185, PWS2323, PWS2326, and PWS 2721 Power Supply User Manual (available in 10
languages) Contains safety and installation information.
Power Cord: based upon the international power option(See page 1,
Certificate of calibration
PWS2000 Linear Power Supplies Documentation Browser CD
Options and Optional Accessories
For the current list of accessories, upgrades, and options available for your PWS2000 Series Power Supply, visit the
Tektronix Web site, www.tektronix.com.
Table 1: Standard accessories
Tektronix pa
number
071-2751-XX
071-2760-XX
Options and
Optional
Accessories.)
063-4282-XX
rt
to
Accessory
PWS2185, PWS2323, PWS2326, and PWS2721 Power Supply Technical Reference, in English.
Contains detailed information about the instrument, including specifications and how to verify
performance. Available for download from www.tektronix.com/manuals.
Power Cord
One of the following:
North America (Option A0). The factory sets the 110V/220V selector switch
to 110 V.
Universal Euro (Option A1). The factory sets the 110V/220V selector switch
to 220 V.
United Kingdom (Option A2). The factory sets the 110V/220V selector switch
to 220 V.
Australia (Option A3). The factory sets the 110V/220V selector switch to 220 V.
Switzerland (Option A5). The factory sets the 110V/220V selector switch to
220 V.
China (Option A10). The factory sets the 110V/220V selector switch to 220 V.
India (Option A11). The factory sets the 110V/220V selector switch to 220 V.
Brazil (Option A12). The factory sets the 110V/220V selector switch to 220 V.
Tektronix p art
number
077-0482-XX
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual1
Getting Started
Specifications
For more specifications, refer to the PWS2185, PWS2323, PWS2326, and PWS2721 Technical Reference.
Table 2: Electrical ratings for the power connection
Model
PWS2185110 V / 220 V50 / 60 Hz
PWS2323110 V / 220 V50 / 60 Hz
PWS2326110 V / 220 V50 / 60 Hz
PWS2721110 V / 220 V50 / 60 Hz
Table 3: Environmental performance
Line Selector
Switch SettingFrequencyFuse RatingMax Power
For 110 V: 5 A TH, 250 V
For 220 V: 2.5 A TH, 250 V
For 110 V: 5 A TH, 250 V
For 220 V: 2.5 A TH, 250 V
For 110 V: 6.3 A TH, 250 V
For 220 V: 3.15 A TH, 250 V
For 110 V: 5 A TH, 250 V
For 220 V: 2.5 A TH, 250 V
350 VA
350 VA
675 VA
350 VA
ParameterPWS2185PWS2323PWS2326PWS2721
Temperature
Humidity
Altitude
Pollution Degree 2, For indoor use only
Operating: +0 °C to +40 °C
Operating:
5% to 95% relative humidity (% RH) at up to +40 °C, non-condensing
Operating: 100% capability up to 2,000 meters
Nominal Voltage Ratings
There are two ranges for all models, selectable by the line-voltage selector switch. Check the voltage select switch on the
bottom before turning on: 110 V setting, 110 / 115 / 120 V
not exceed 10% of the nominal rated voltage.
Float Voltage Rating
Float voltage rating: up to 100 V (DC + peak AC) between earth ground and any output terminal.
Operating Requirements
1. Place the instrument on a bench or similar surface.
AC; 220 V setting, 220 / 230 / 240 VAC. Fluctuations must
2. Before operating, ensure that the ambient temperature is between +0 °C and +40 °C (+32 °F to +104 °F).
WARNING. To ensure proper cooling, keep the fron
operate the instrument on a table without the handle in the down and locked position. This allows air flow to the bottom of
the instrument.
2PWS2185, PWS2323, PWS2326, and PWS2721 User Manual
t, sides, and rear of the instrument clear of obstructions. Do not
Getting Started
WARNING. Observe all safety precautions listed in this manual before using this product and any associated instruments.
Although some
hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards
and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and
maintenance i
performing any maintenance, disconnect the line cord and all test cables. Operators of this instrument must be protected
from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from
every connec
circumstances must be trained to protect t hemselves from the risk of electric shock. If the circuit is capable of operating at or
above 1000 volts, no conductive part of the circuit may be exposed.
instruments and accessories would be used with non-hazardous voltages, there are situations where
nformation carefully before using the product. Refer to this manual for complete product specifications. Before
tion point. In some cases, connections must be exposed to potential human contact. Product operators in these
WARNING. Us
short-circuit output current of the power supply. If there is more than one load, then any pair of load wires must be capable
of safely carrying the full-rated short-circuit output current of the power supply.
WARNING.
WARNING. To reduce risk of fire and shock, ensure the mains supply voltage fluctuations do not exceed 10% of the
operating volta
e properly rated load wires. All load wires must be heavy enough not to overheat when carrying the maximum
Do not loosen any screw on this product. There are no user serviceable components inside.
ge range.
Installing the System
This section contains information on how to install your PWS2000 power supply.
Unpack the instrument and check that you received all the items listed as standard accessories.
Check that you also received any other accessories that you ordered with your instrument.
Check the Tektronix Web site (www.tektronix.com) for the most current information.
To verify that the power supply is ready to use, follow these procedures:
Powering the Instrument On and Off
To power on the inst
1. Make all the connec
2. Properly set the 1
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual3
rument follow these steps:
tions.
10 V / 220 V selector switch on the bottom of the instrument.
Getting Started
3. Connect the power cord that was provided with the inst rument to the power connector on the rear panel. C onnect the
4. Push the power button on the front panel.
To power off the instrument, push the front panel power button.
power cord plug to a properly grounded electrical outlet.
WARNING. T
o satisfy safety requirements, always use l oad wires heavy enough not to overheat when carrying the maximum
short-circuit output current of the power supply. If there is more than one load, then every pair of load wires must be c apable
of safely carrying the full-rated current of the power supply.
What to Do if the Power Supply Does Not Turn On
To solve problems you might encounter when turning on the instrument, follow these steps:
1. Verify that there is AC power to the power supply.
First, check that the AC power cord is firmly plugged into the power connector on the rear panel of the power supply.
You should also make sure that the AC power source you plugged the power supply into is energized. Then, check
that the power supply is turned on.
2. Verify the power-line voltage settings.
Check that the line voltage selector switch on the bottom of the instrument is set to the proper value for your country
(110 V
NOTE. Under certain circumstances, powering the instrument from a mains voltage for which it is not configured can
cause the mains fuse to open.
3. Verify that the correct power-line fuse is installed.
or 220 VAC). Change the voltage setting if it is not correct.
AC
If the fuse is damaged, replace the fuse for your power supply.
Ifyousetthelineselectionto110V,usea5A,TH250Vfuse.
If you set the line selection to 220 V, use a 2.5 A, TH 250 V fuse.
4. If you need more help, contact Tektronix.
4PWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Getting Started
Check the Output
The following procedures check that the power supply develops its rated outputs and properly responds to operation
from the front panel.
Voltage output check. To verify basic voltage functions without a load, follow these steps.
1. Remove all leads from the output connectors.
2. Turn on the power supply.
3. Push Menu to bring up the R
4. Push Enter.
5. Push the up a rrow button to select Yes.PushEnter to restore the default settings.
6. Push the output On/Off button to enable the output. The OFF message above and to the left of the voltage display willturn from Off to CV. The meter indicator should be lit and the meter readings should show 1 V and 0 A.
7. Check that the front-panel voltmeter properly responds to the number keys.
Push V-set, use the number keys to set the voltage value to 0 and push Enter. Check if the displayed voltage value is
approximately 0 V and check if the displayed current value is approximately 0 A. You can confirm the 0 V setting with
a voltmeter.
8. Push V-set and use the numeric keys and Enter button to set the voltage value to the maximum allowable for your
power supply, as indicated on the front panel of the unit.
9. Check if the displayed voltage value is approximately the same value as the voltage setting.
eset All menu. This menu allows you to set the instrument to default settings.
Current output check. To verify the basic current functions with a short across the power supply output, follow these
steps:
1. Remove all leads from the output connectors.
2. Turn on the power supply.
3. Push Menu to bring up the Reset All menu. This menu allows you to set the instrument to default settings.
4. Push Enter.
5. Push the up arrow button to select Yes. Push Enter to enable the default settings.
6. Ensure that the output is disabled and the display OFF message is turned on. If needed, push the output On/Off button.
7. Use an insulated test lead to connect a short across the (+) and (-) output terminals.
Use a wire size sufficient to handle the maximum current. You should use at least a 22 gauge wire.
WARNING. To satisfy safety requirements, always use load wires heavy enough not to overheat when carrying the maximum
short-circuit output current of the power supply. If there is more than one load, then every pair of load wires must be capable
of safely carrying the full-rated current of the power supply.
8. Push the output On/Off button to enable the output. The CC message should be lit.
9. Push I-set and use the numeric keys and Enter button to set the current value to 0 A. Check if the displayed current
value is approximately 0 A.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual5
Getting Started
10. Push I-set and use the numeric keys and Enter button to set the current value to the maximum allowable for your current
supply. Check i
f the displayed current value is approximately the same value as the maximum allowable.
11. Turn off the po
Cleaning
Inspect the power supply as often as operating conditions require. To clean the exterior surface, perform the following steps:
1. Remove loose dust on the outside of the power supply with a lint-free cloth. Use care to avoid scratching the display.
2. Use a soft cloth dampened with water to clean the power supply. Use an aqueous solution of 75% isopropyl alcohol
CAUTION. To avoid damage to the surface of the power supply, do not use any abrasive or chemical cleaning agents.
CAUTION. Avoid getting moisture inside the unit during external cleaning. Use only enough cleaning solution to dampen
the cloth or swab.
wer supply and remove the short wire from the (+) and (-) output terminals.
for more efficient cleaning.
6PWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Operating Basic
s
Operating Bas
ics
Front Panel at a Glance
Controls and display elements are shown in the following illustrations and tables.
1. Display containing information about the settings or output for voltage (left) and current (right)
2. Up, down, right, and left arrow keys (▲ and ▼) and Enter button
3. Output connectors
4. Save and Recall function buttons
5. Number keys (0 to 9 and Esc) for direct numeric entry
6. V-Set, I-Set, Menu, and Output On/Off function buttons
7. Power button
Function button descriptions
ButtonDescription
Sets the voltage limit
Sets the current limit
Saves the present settings to a specified setup memory location (1 to 20). Select the memory location
with the multipurpose knob, the up or down arrow keys, or the numeric keypad. The power supply
saves the settings after you push Enter.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual7
Operating Basic
Function button descriptions (cont.)
ButtonDescription
Menu button descriptions
Primary
MenuSecondary MenuDescription
Reset All
Max Volt
Key Lock
Out RecallOn (Def)
Save LastOn (Def)
s
Recalls a saved setting from a specified setup memory location (1 to 20). Select the memory location
with the multipurpose knob, the up or down arrow keys, or the numeric keypad. The power supply
recalls the settings after you push Enter.
Use to access the following power supply settings: Reset All, Max Volt, Key Lock, Out Recall, Save
Last, Key Beep, and Sys Info. Push Enter to select the displayed menu item.
Turns on or off the output channel of the power supply. The regulation mode, constant voltage (CV) or
constant current (CC), is shown on the display when the output is turned on.
Backs out of the selected function. If the instrument’s focus is in a menu, pushing Esc will back up
one menu l
Yes
No
Off
Off
evel.
Returns the instrument to the factory default setup values.
Select to return the instrument to the factory default setup values and then press
the Enter button
Select if y ou do not want to return the instrument to the factory default setup values
and then press the Enter button
Sets the maximum output voltage value to which you can set the instrument
When activated, this feature locks the front panel controls and prompts for a
password to enable settings changes. This feature does not lock the power switch
or the output on/off switch.
Sets the power output On/Off state after power up. “On” restores the state to that
which was in use before the power was last turned off. “Off” disables this function
and configures the output channel to power up on the off state.
Recalls the operating parameters of the power supply after power up. It does this by
saving the last setting of operating parameters before you turn the instrument off
and then restoring the saved setting when you turn the instrument back on.
NOTE. Wait 3 seconds after changing the settings to allow the settings to be
completely stored before powering off the instrument
Key Beep
Sys InfoProvides instrument information including model number, serial number, and
Turns on or off a beeper sound when you push a button or press a key. “On”
enables the key sound. “Off” disables it.
software version.
Display messages
SymbolDescription
OFFThe power supply output is off
8PWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Display messages (cont.)
SymbolDescription
CVConstant voltage mode
CCConstant current mode
MeterThe Volt meter display is active
LockFront panel controls are locked. Enter password to unlock.
Rear Panel at a Glance
Operating Basic
s
1. Cooling vents
2. 110 V/220 V power connector
3. Factory test port
CAUTION. Unauthorized use of the factory test port could damage this product.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual9
Operating Basic
4. 110 V/220 V selector switch
s
Front-panel Operation
Within a few seconds after powering on, the power supply goes into Meter mode. It displays the actual voltage and current
output value. To see the voltage or current limits, press the Enter button. Pressing the V-Set or I-Set button puts the
meter into Set mode. Both voltage and current limit settings will show, but either the voltage or current setting will flash to
indicate which parameter can be adjusted. The settings will continue to show until the power supply returns to Meter mode.
Press the up and down arrow keys to adjust the selected limit. The power supply automatically goes from Set mode to
Meter mode if you do not press any key for 3 seconds.
You can enable or disable the output of the power supply from the front panel by pushing the Output On/Off button. When
the output is off, the OFF message will appear on the display above the current and voltage values.
The display shows the present operating status of the power supply with display messages. When the power supply operates
in constant voltage mode, the CV message displays above the voltage. When it operates in the constant current mode,
the CC message displays above the voltage.
NOTE. If the front panel was locked with a password, enter the correct password after you push one of the front panel
buttons, then you can change the settings.
NOTE. To cancel a function operation (V-set, I-set, Save, and Recall), push the Esc button.
10PWS2185, PWS2323, PWS2326, and PWS2721 User Manual
Operating Basic
Configuring the Instrument for Your Application
The menu system includes settings like Max Volt that determines the maximum voltage output of the power supply and
settings, like Out Recall and Save Last, that determine how the instrument initializes itself on power-up.
This power supply features a constant voltage/constant current automatic crossover. This feature permits continuous
operation in the transition from constant-voltage mode to constant-current mode as the load changes. The intersection of
the constant-current and constant-voltage modes is called the crossover point.
For example, if the load is such that the power supply is operating in constant-voltage mode, the power supply provides
a regulated output voltage. The output voltage remains constant as the load increases until the preset current limit is
reached. Then the c rossover occurs. At that point, the output current becomes constant and the output voltage drops in
proportion to further load increases.
Crossover is indicated by the front panel CC and CV messages. If the CV message appears, the instrument is operating in
constant-voltage mode. If the CC message appears, the instrument is operating in constant-current mode.
Crossover from the constant-current mode to the constant-voltage mode also occurs automatically in response to a decrease
in load. For example, suppose you are charging a 12 V battery. Initially, the open circuit voltage of the power supply is
preset for 13.8 V. A low-battery places a heavy load on the power supply, and it operates in constant-current mode. You
adjust the instrument to charge the battery at the rate of 1 A. As the battery becomes charged and its voltage approaches
13.8 V, the load decreases to the point where the battery no longer demands the full 1 A charging rate. T he power supply
then crosses over to constant-voltage mode.
s
Initializing to the Default Setup
Use the default setup to get the power supply into a default initial state.
1. Remove all leads from the output connectors.
2. Turn on the power supply.
3. Push Menu tobringuptheReset System menu. This menu allows you to set the instrument to default settings.
4. Push Enter.
5. Push the up arrow button to select Yes and push Enter to enable the default settings.
The default settings are:
Output On/Off = OFF
V-Set = 1.000V
I-Set = 0.1000A
Max Volt Set = Off
Save Last = On
Out Recall = On
Key Beep = Off
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual11
Operating Basic
Setting the Current Limit (I-Set)
You may set the current limit from 0 A to the maximum current value of each model. The maximum current rating is shown on
the instrument name plate.
1. Push I-Set.
2. Use the numeric keys and push Enter to set the current limit. You can also use the up, down, right, and left arrow keys.
Setting the Voltage Limit (V-Set)
You may set the voltage limit from 0 V to the maximum voltage rating shown on the instrument nameplate.
1. Push V-set.
2. Use the numeric keys and push Enter to set the voltage limit. You can also use the up, down, right, and left arrow keys.
Save and Recall Setups (SAVE and RECALL)
You can store up to 20 different setups in setup memory locations (1 to 20). Each setup includes the set voltage limit, the
set current limit, and the maximum output voltage value. When shipped from the factory, setup memories 1 through 20
are empty. Save and recall setups as follows:
s
Saving setups.
1. After you set up the power supply (voltage limit, current limit, and the maximum output voltage) push the Save button.
2. Use the number keys or the arrow keys to select the setup memory (1 to 20) that you w ant to store the values in.
3. Push Enter to confirm the memory location.
Recalling setups.
1. Push Recall.
2. Use the number keys or the arrow keys to select the setup that you want to recall.
3. Push Enter.
Set the Maximum Voltage (>MAX VOLT)
This control determines the maximum voltage that you can set using the V-set control. This can help keep accidental
over-voltage from being applied to sensitive loads. To set the maximum voltage, follow these steps:
1. Push Menu.
2. Use the down arrow key to select Max Volt.
3. Push Enter and use the number keys to enter the voltage value.
4. Push Enter to turn on the maximum voltage feature. Limit Done should appear briefly and then Max Volt will appear.
5. Push Esc to exit the menu.
6. Push V-Set.
7. Use the numeric keys or the arrow keys to change the voltage value. The value must be less than the maximum
voltage output.
12PWS2185, PWS2323, PWS2326, and PWS2721 User Manual
8. Push Enter.
9. Push Esc to exit the menu system.
Operating Basic
s
NOTE. The defa
ult maximum voltage is the full voltage range of the particular power supply being used.
Recall the Power Supply ON/OFF Output State at Power On (>OUT RECALL)
This parameter determines the initial On or Off output state after the power supply is powered on. If you select On, the power
supply will restore the state of the output to that which was in use before the power was last turned off. If the output was
turned On when the power supply is turned off or l oses power then the output will return to the On state when the power
supply is turned back on or power is restored. Off will disable this function and the output channel will always be set
to Off after the power supply is powered on.
To enable or disable this control,
1. Push the Menu.
2. Use the down arrow key to select OUT RECALL.
3. Push Enter.
4. Use the up arrow key to select On or Off.
5. Push Enter.
6. Push Esc to exit the menu system.
NOTE. The default selection is set to Off.
Recall the Power Supply Operating Parameters at Power On (>SAVE LAST)
arameter determines whether the power supply saves its most recent settings, such as voltage and current, and
This p
restores these settings at power on. If you set this parameter to Off then the power supply returns to the default settings
at power on. If you select On, the power supply will restore the state to that which was in use before the power was
urned off.
last t
able or disable this control,
To e n
1. Push
2. Use t
3. Pus
4. Use
5. Pus
6. Pus
NOTE. The default selection is set to On.
Menu.
he down arrow key to select Save Last.
h Enter.
the arrow key s to select On or Off.
h Enter.
h Esc to exit the menu system.
PWS2185, PWS2323, PWS2326, and PWS2721 User Manual13
Operating Basic
Set the Key Beep (>KEY BEEP)
This control can switch on or off the sound that occurs when you push any button o r press any key. To enable or disable
this feature,
1. Push Menu.
2. Use the down arrow key to select Key Beep.
3. Push Enter.
4. Use the arrow keys to select On or Off.
5. Push Enter.
6. Push Esc to exit the menu system.
NOTE. The default selection is set to Off.
s
14PWS2185, PWS2323, PWS2326, and PWS2721 User Manual