TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
•In North America, call 1-800-833-9200.
•Worldwide, visit to www.tek.com find contacts in your area.
Table of Contents
Table of Contents
List of Figures..............................................................................................................................................................................10
List of Tables............................................................................................................................................................................... 12
Getting help and support.............................................................................................................................................................15
Related documentation........................................................................................................................................................ 15
Required equipment and accessories..................................................................................................................................16
Installing the software.......................................................................................................................................................... 16
Launch the application......................................................................................................................................................... 18
Close the application............................................................................................................................................................18
Help panel.....................................................................................................................................................................32
Figure 34: TP2 Calibration: IL for DMI/CMI.................................................................................................................................50
Table 26: TP2 Calibration: IL for DMI/CMI.................................................................................................................................. 50
Table 40: JTOL Test (Results Table)........................................................................................................................................... 68
Table 41: JTOL Test: Save Results............................................................................................................................................. 69
PCIe5.0 (Base) Receiver Test Application Help 13
Welcome
Welcome
Welcome to the PCIe5.0 (Base) TekRxTest application. This application performs the test as per the Gen 5 Base specification Revision 5.0
Version 1.0.
Figure 1: TekRxTest - PCIe5.0 Base application
Receiver testing is accomplished by connecting the output of BERT PPG (which can produce specific PCIe test patterns) to the input of the
DUT through a specialized set of fixtures and cables. The BERT can be programmed to add different amounts of random jitter, sinusoidal
jitter, differential, Common mode interference along with variable signal amplitude, preshoot, and de-emphasis. Output of the DUT is
connected to the BERT error detector to identify bit errors on the DUT Tx traffic, either during loopback or during sweep of one of the stress
parameters. Any error detected can be assumed to be generated from the DUT Tx path as a result of either the DUT experiencing a bad
bit-decision at its receiver or uncompensated back channel loss at the error detector of the BERT.
Key features and benefits
•PCIe Gen5 Receiver JTOL Testing as per Base specification for Non-Root complex / Root Complex devices.
•Automated calibration, forced loopback initiation, and testing.
•Jointly with Anritsu BERT MP1900A series, the receiver solution provides the tools and flexibility needed to visualize and control
impairments , observe real-time eye performance, etc. for PCIe Gen5 devices.
•Reliable and accurate results reduce the test execution time and minimize the skill-set required to perform calibration and testing.
14
Getting help and support
Getting help and support
Related documentation
The following documentation is available as part of the PCIe5.0 (Base) test application.
Table 1: Product documentation
ItemPurposeLocation
Application HelpApplication operation and User Interface
details
See also
Technical support on page 15
Technical support
Tektronix values your feedback on our products. To help us serve you better, please send us your suggestions, ideas, or comments on
your application or Real Time Oscilloscope. Contact Tektronix through mail, telephone, or the Web site. See Contacting Tektronix on page
0 at the front of this document for contact information.
Help panel of the application
When you contact Tektronix Technical Support, please include the following information (be as specific as possible):
General information
•All instrument model numbers
•Hardware options, if any
•Modules used
•Your name, company, mailing address, phone number, and FAX number
•Please indicate if you would like to be contacted by Tektronix about your suggestion or comments.
Application specific information
•Software version number
•Description of the problem such that technical support can duplicate the problem
•If possible, save the setup files for all the instruments used and the application
Required2Connector savers (1.85 mm)1.85 mm oscilloscope channel
accessory
Anritsu MP1900A
Anritsu
3rd party
Required1Bit Error Rate Tester (BERT)
1
equipment
DJATektronixEquipment
Required1DPOJET advanced optionDPOJET advanced Jitter, Eye and
SW option
SDLA64TektronixEquipment
SW option
174-6659-01TektronixTek
Required1Serial Data Link Analysis
(SDLA) Software
Required1Cable pair; SMA - SMPRefclk connection between DUT &
accessory
PMCABLE1MSwiftbridge Tek
accessory
Required2Cable pair; 2.92-to-2.92
mm, Straight, 1.5 ps phasematched, 40 GHz
Gen5 Base Test
Fixture Set
PCI-SIGTest fixturesRequired1Gen 5 Base Rev3 Test
2
Fixtures
RXSW-NLP-PCIE5 TektronixSW optionRequired1PCIe Gen5 Receiver Software Gen5 BASE and CEM Rx test
RXSW-NL1-PCIE5Gen5 BASE and CEM Rx test
RXSW-FLP-PCIE5Gen5 BASE and CEM Rx test
RXSW-FL1-PCIE5Gen5 BASE and CEM Rx test
50 GHz or better
input connection
Configuration provided by 3rd party
Timing Analysis SW option
Embedding/De-embedding/sparameter filter generation/
Receiver Virtualization and
Analysis Software
BERT
Equipment connections to replica
channel & DUT
Rev3 is Meg6 material with MMPX
connectors
3
software - Node-Locked, Perpetual
software - Node Locked, Time
Based, 1 year
software - Floating, Perpetual
software - Floating, Time Based, 1
year
Installing the software
Complete the following steps to download and install the latest PCIe5.0 (Base) TekRx test application.
1. Go to www.tek.com.
1
Gen5 BaseTest Fixtures are not backwards compatible for Gen3 & Gen4 Base Rx
2
Gen5 BaseTest Fixtures are not backwards compatible for Gen3 & Gen4 Base Rx
3
It is assumed MMPX cables and MMPX to SMA adaptor cables for test fixture connections are included with the fixture kit
16
Getting started
2. Click Downloads. In the Download menu, select DOWNLOAD TYPE as Software and enter PCIe5.0 (Base) in the MODEL OR
KEYWORD field and click SEARCH.
3. Select the latest version of the software and follow the instructions to download.
4. Copy the executable file into the instrument you wish to install the software (Real-time oscilloscope or PC).
5. Follow the installation instruction that is available in the website. The software is installed at C:\Program
Files\Tektronix\BERTScope\RxTest60
6. Double click the shortcut icon on the desktop to launch the application.
Note:
•The PCIe5.0 (Base) TekRx test application can be installed on a Tektronix real-time oscilloscope or a PC (optional).
•You must install the TekRxService and SigTest application in the real-time oscilloscope to successfully connect the application
with the real-time oscilloscope.
PCIe5.0 (Base) Receiver Test Application Help 17
Operating basics
Operating basics
Launch the application
To launch the PCIe5.0 (Base) test application, double click the shortcut icon TekRxTest on the desktop and select PCIe5.0 (Base) in the
application window.
Figure 2: TekRxTest application window
Close the application
To exit the application, click on the application title bar. Follow on-screen instructions to save the unsaved session or test setup.
Using other methods to exit the application may result in abnormal termination of the application.
Note:
Launch Real-Time Oscilloscope
The TekVISA Socket Server application on the oscilloscope provides the necessary connectivity between the TekRxTest application
and scope. Although it is launched in the background when the scope boots up and the socket is initialized for communication, it is
recommended to verify the status by clicking on the Desktop Tray ―› TekVISA LAN Server Control as shown in the image below. If it is
ready to exchange data, then a wizard would appear as in the below image.
18
Figure 3: Launch Real-Time Oscilloscope
Note: In the unlikely event when the socket is not initialized, the process can be started by clicking on “Start Socket Server” which
gets enabled during such a scenario.
Operating basics
Launch TekRxService
The PCIe5.0 (Base) TekRxTest application interfaces with the oscilloscope for data acquisition, analysis and data retrieval utilizing
TekRxService application. This software module should be launched at the time of initiating the TekRxTest application.
PCIe5.0 (Base) Receiver Test Application Help 19
Operating basics
Figure 4: TekRxService application window
TekRxService has to be launched if the application is being run on an external PC. To launch the application, double click
Note:
the TekRxService batch file shortcut icon in the desktop of the real-time oscilloscope.
Application panels
Application panels overview
The PCIe5.0 (Base) TekRxTest application uses panels to group the configurations and settings. Click on any panel to configure the
associated settings. A panel may have one or more tabs that lists the selections available in that panel. Controls in a tab may change
depending on the settings made in the same tab or another tab.
Table 2: Application panels overview
ParameterDescription
Connections
Settings
Help
This panel displays the real-time oscilloscope and BERT connection settings. You can
connect to a real-time oscilloscope and BERT by entering the IP address of the
instruments.
This panel allows configuring various settings for the Components, TP3 and TP2
Calibration.
This panel displays the application help.
Table continued…
20
ParameterDescription
Calibrations
This panel allows you to configure the calibration parameters for TP3/TP2 and save the
results.
Operating basics
Tests
This panel allows you to configure the JTOL test settings and view the results.
Connections panel
The connections panel allows you to connect to a real-time oscilloscope and BERT with the PCIe5.0 (Base) TekRxTest application. Enter
the IP address of the instruments and click Connect to establish the connection.
Figure 5: Connections panel
Table 3: Connections panel
ConnectionsDescription
BERT
RT Scope
PCIe5.0 (Base) Receiver Test Application Help 21
Enter the BERT IP address in the address field and click Connect. When the BERT is connected
successfully, the circle next to BERT in the right end corner turns green.
Enter the RT Scope IP address in the address field and click Connect. When the RT Scope is connected
successfully, the circle next to RT Scope and TekRxService in the right end corner turns green.
Note: Before you click Connect, if the TekRxTest application is running on an external PC, make
sure to launch the TekRxService in the real-time oscilloscope.
Operating basics
Settings panel
This panel allows you to configure the settings for instruments, calibrations, and remote access. Click any tab to configure the associated
settings.
Figure 6: Settings panel
Table 4: Settings panel configurations
ItemDescription
Restore Defaults
Save
Recall
Restores the application with default settings.
Saves the current test setup.
Recalls the saved test setup.
Components settings
The components settings display the parameters for RT Scope and TekRxService.
22
Operating basics
Figure 7: Components: RT Scope
Table 5: Components: RT Scope
ParameterDescription
Positive Channel
Negative Channel
Sample Rate
Select the generator data positive channel from BERT.
Select the generator data negative channel from BERT.
Displays the RT Scope sample rate in GS/s.
PCIe5.0 (Base) Receiver Test Application Help 23
Operating basics
Figure 8: Components: TekRxService
Table 6: Components: TekRxService
ParameterDescription
Analysis Time Out
Sigtest Version
Seasim VersionDisplays the Seasim version.
Enter the timeout value for Sigtest analysis.
Enter the Sigtest version.
TP3 Calibration
The TP3 calibration tab allows you to configure the channel settings including the attenuators and component de-embedding, multi-tone
calibration, and insertion loss calculation.
24
Operating basics
Figure 9: TP3 Calibration: Attenuator Settings
Table 7: TP3 Calibration: Attenuator Settings
ParameterDescription
Include Ch1 De-Embedding filter fileEnable to apply Ch1 de-embedding filter file.
Ch1 De-Embedding filter fileClick to browse and navigate to the path and select the required Ch1 de-embedding filter
file.
Ch1 External AttenuationEnter the Ch1 external attenuation value in dB.
Include Ch2 De-Embedding filter fileEnable to apply Ch2 de-embedding filter file.
Ch2 De-Embedding filter fileClick to browse and navigate to the path and select the required Ch2 de-embedding filter
file.
Ch2 External AttenuationEnter the Ch2 external attenuation vaue in dB.
PCIe5.0 (Base) Receiver Test Application Help 25
Operating basics
Figure 10: TP3 Calibration: Calibrations
Table 8: TP3 Calibration: Calibrations
ParameterDescription
AmplitudeDisplays the calibration target for generator amplitude source.
RJDisplays the calibration target for random jitter source.
SJ @ 100 MHzDisplays the calibration target for sinusoidal jitter source @ 100 MHz.
Multi-tone Calibration
Frequency Settings: Frequencies at which the SJ calibration needs to be performed for JTOL Test.
Frequency (MHz)
Lower Amplitude Limit (UI p-p)Displays the table of lower amplitude limit values at which SJ calibration starts for that
Higher Amplitude Limit (UI p-p)Displays the table of higher amplitude limit values at which SJ calibration ends for that
Min FrequencyEnter the minimum frequency value.
Max FrequencyEnter the maximum frequency value.
# FrequenciesEnter the desired number of frequencies within the specified range.
# PointsEnter the desired number of points used for calibration.
GenerateClick to view the table populated with the frequencies.
DefaultClick to view the table populated with default list of frequencies.
Select to enable the multi-tone calibration. It displays the calibration settings for multiple
tones.
Displays the table of frequencies in MHz for which Multi-tone calibration is to be performed.
frequency.
frequency.
26
Operating basics
TP2 Calibration
The TP2 calibration tab allows you to configure the Attenuator Settings, DMI and CMI calibration, CTLE and Preset Selection, and
Stressed Eye Parameters.
Figure 11: TP2 Calibration: Attenuator Settings
Table 9: TP2 Calibration: Attenuator Settings
ParameterDescription
Include Ch1 De-Embedding filter fileEnable to apply Ch1 de-embedding filter file.
Ch1 De-Embedding filter fileClick to browse and navigate to the path and select the required Ch1 de-embedding filter
file.
Ch1 External AttenuationEnter the Ch1 external attenuation value in dB.
Include Ch2 De-Embedding filter fileEnable to apply Ch2 de-embedding filter file.
Ch2 De-Embedding filter fileClick to browse and navigate to the path and select the required Ch2 de-embedding filter
file.
Ch2 External AttenuationEnter the Ch2 external attenuation vaue in dB.
Replica Channel Embedding / Cable DeEmbedding
Filter File TypeSelect the required filter type.
Differential Filter FileBrowse and navigate to the path and select the required differential filter file. Enabled only
Ch1 Filter FileClick to browse and navigate to the path and select the required Ch1 filter file. Enabled only
Table continued…
Select to enable the replica channel embedding or the cable de-embedding.
when filter file type is selected as Differential.
when filter file type is selected as Single ended.
PCIe5.0 (Base) Receiver Test Application Help 27
Operating basics
ParameterDescription
Ch2 Filter FileClick to browse and navigate to the path and select the required Ch2 filter file. Enabled only
when filter file type is selected as Single ended.
Figure 12: TP2 Calibration: DMI and CMI
Table 10: TP2 Calibration: DMI and CMI
ParameterDescription
DMIDisplays the nominal DMI value in mV.
CMIDisplays the nominal CMI value in mV.
28
Operating basics
Figure 13: TP2 Calibration: CTLE and Preset Selection
Table 11: TP2 Calibration: CTLE and Preset Selection
ParameterDescription
# acqs
Analysis ToolSelect the required analysis tool.
Enter the number of waveform acquisitions to be carried out for averaging during this
measurement.