Product Description
The P6616 general-purpose logic probe connects the Tektronix MSO/DPO5000 Series and MSO4000B Series of mixed-signal oscilloscopes to digital buses and signals on your target system. The probe contains 16 data channels split between two lead sets (GROUP 1 and GROUP 2).
The rstleadineachsetisidentified by blue insulation, and the remaining seven leads are gray. All leads include a ground connection at the tip. You can connect the probe leads separately to the target system, or group the leads together using the probe tip holders.
ions
83100*
Setting Up the Probe
To set and view the digital channel parameters, do the following:
On MSO/DPO5000 Series instruments, select Vertical>Di
gital Setup.
On MSO/DPO4000B Series instruments, push the D15–D0 button.
The parameters listed below can be set on each digital channel:
Threshold v
oltage and vertical position (the default
threshold setting is 1.4 V)
Signal height and position (set once for all 16 channels)
Channel label
To set and vi
ew bus characteristics, do the following:
On MSO/DPO5000 Series instruments, use the controls in the Bus Setup screen.
On MSO/DPO4000B Series instruments, push the B1 to B4 buttons.
The setup screens allow you to set and view bus characteristics such as:
Clock type
Bus type (Serial or Parallel)
Bus width
Display format (Hex, Binary, or ASCII symbols)
Parallel bus setup information is resident on some oscilloscope models. However, for other buses such as SPI and I2C, you must have the appropriate option. See your oscilloscope manual or product data sheet for nomenclature and ordering details.
Functional Check
Logic activity immediately displays on all c onnected, active channels. If you do not see an active signal:
1. Push the Tr
igger button.
2. Select Edge for trigger type.
3. Select the channel that you are setting up as the source.
4. On MSO/DPO4000B Series instruments, push the Autoset
button.
If you do not see an active signal, try another probe channel (or analog probe) to verify circuit activity at the test point.
Typical Application
1. Use the P6616 probe to view digital signals on a system bus.
2. Use an analog probe, such as the TPP0500 or TPP1000 active probe to view analog waveform information.
Specications
Table 1: Electrical and mechanical specications
Characteristic Description
Input channels 16 digital
Input resistance
Input capac
Input signal swing
Maximum nondest– ructive input signal
Threshold voltage ± 40 V
Minimum detectable pulse width
Maximum input toggle rate
Digital channel-to­digital channel skew
Probe length
itance
Minimum 400 mV p-p
Maximum
100 k±1.0%
3.0 pF
30 V p-p, 200 MHz (centered around the DC threshold voltage) at the probe tip
10 V p-p, 200 MHz (centered around the DC threshold voltage) at the probe tip
30 V p-p, 42 V peak, ±50 VDC
1ns
500 MHz
200 ps
1.0 m (3.28 ft)
Table 2: Environmental specications
Characteristic Description
Temperature
Operating Nonoperating
Humidity
Operating Nonoperating
Altitude
Operating Nonop
erating
0 °C to +50 °C (+32 °F to +122 °F) –55 °C to +75 °C (–67 °F to +167 °F)
5% to 95% relative humidity 10% to 95% relative humidity
4.6 km (15,092 ft) maximum 50,000 ft) maximum
15 km (
Equipment Recycling. This product complies with the European Union’s requirements according
ctive 2002/96/EC on waste electrical
to Dire and electronic equipment (WEEE). For more information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Safety Summary
Connect and Disconnect Properly. Connect the probe output
to the measurement instrument before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement instrument.
Observe All Terminal Ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
Do not Operate Without Covers. Do not touch exposed connections and components when power is present.
Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present.
Connecting the Probe to the Oscilloscope
Connect the probe as shown in the illustration below.
1. Insert the probe label-side up into the connector on the oscilloscope.
2. To remove the probe, squeeze the buttons on the side and pull out the probe.
Connecting the Probe to Your Circuit
Attach the probe to the circuit using the connectors and adapters shown on the back of these instructions. Select the best method for your needs, and then proceed to Setting up the Probe.
Accessories
The following standard accessories ship with the probe and are shown in the illustration on the following page.
Item Description Quantity Part number
Logic probe accessory kit Item 1–6 020-2662-XX
1 Extension ground tip
2 Probe tip
3
IC grabber 1 set of 20
4 Probe tip holder 2 ea 352-1115-XX
5
8” Ground lead 1 set of 2
6
3” Ground lead 1 set of 8
1
ructions
Inst
1
Instructions are included with the probe, but not in the accessory kit. The instructions can be downloaded at www.tektronix.com/manuals.
1 set of 20
1 set of 10
1ea 071-
020-2711-XX
131-5638-11
020-2733-XX
020-2713-XX
020-2712-XX
2831-XX
These optional accessories can be ordered for your probe:
cription
Des
P6960 Probe D-MAX Footprint to Square Pin Header Adapter
t number
Par
NEX-P6960PIN
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualied service personnel.
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Safety Terms and Symbols in This Manual.
These terms may appear in this m anual:
WARNING. Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or
practices that could result in damage to this product or other property.
Symbols o n the Product. This symbol may appear on the product:
Contacting Tektronix
Web site: www.tektronix.com
Phone: 1-800-833-9200
Address: Tektronix, Inc.
Email:
partment or name (if known)
De 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
techsupport@tektronix.com
Warranty Information
For warranty information, go to www.tektronix.com/warranty.
x
Connecting the Probe to the Circuit
Copyright © Tektronix, Inc. All rights reserved. www.tektronix.com
xx
P6616
汎用ロジック・プローブ
取扱説明書
2
31-00
071-28
製品の説明
P6616 型汎用ロジック・プローブは、当社 MSO/DPO5000 シ リーズおよび MSO4000B シリーズ・ミックスドシグナル・オシロ スコープをターゲット・システムのデジタル・バスおよび信号に 接続するために使用します。プローブは、16 のデータ・チャ ンネルが 2 つのリード・セットに分割されています(GROUP 1 および GROUP 2)。
両セットの最初のリードは青色の絶縁体で示され、他の 7 本 のリードは灰色です。すべてのリードのチップにはグランド接 続があります。プローブ・リードは、ターゲット・システムに個 別に接続したり、プローブのチップ・ホルダを使用してグルー プ化したりすることができます。
プローブのセットアップ
デジタル・チャンネルのパラメータを設定したり表示するに は、次のようにします。
MSO5000/DPO5000 シリーズの機器では、Vertical>Digital Setup を選択します。
MSO/DPO4000B シリーズの機器では、D15–D0 ボタンを 押します。
各デジタル・チャンネルについて、下記のパラメータを設定 できます。
スレッショルド電圧および垂直位置(デフォルトのスレッ ショルド電圧は 1.4 V)
信号の高さおよび位置(全 16 チャンネルを一括設定)
チャンネル・ラベル
バス特性を設定したり表示するには、次のようにします。
MSO/DPO5000 シリーズの機器では、Bus Setup スクリー ンのコントロールを使用します。
MSO/DPO4000B シリーズの機器では、B1 ~ B4 のボタン を押します。
セットアップ画面で、次のバス特性を設定したり表示したりで きます。
クロックの種類
バスの種類(シリアルまたはパラレル)
バス幅
表示形式(16 進、2 進、または ASCII シンボル)
一部のオシロスコープ・モデルにはパラレル・バスの設定情 報が格納されています。しかし SPI や I2C など、その他のバ スについては適切なオプションが必要です。名称と発注情報 については、ご使用のオシロスコープのマニュアルまたは製 品データ・シートを参照してください。
機能チェック
接続されたすべてのアクティブなチャンネルについて、ロジッ ク動作が直ちに表示されます。アクティブな信号が表示され ない場合は、次の操作を行ってください。
1. Trigger ボタンを押します。
2. トリガのタイプとして Edge を選択します。
3. ソースとしてセットアップするチャンネルを選択します。
4. MSO/DPO4000B シリーズの 機器では、 Autose
t ボタン
を押します。
アクティブな信号が表示されない場合は、他のプローブ・チャ ンネル(またはアナログ・プローブ)を使用して、テスト・ポイン トの回路動作を確認してください。
主な用途
1. P6616 型プロ ーブは、システム・バスのデジタル信号の 観測に使用します。
2. アナログ波形情報を観測するには、TPP0500 型または TPP1000 型能動プローブなどのアナログ・プローブを使 用します。
下記のオプショナル・アクセサリをご購入いただけます。
説明 部品番号
P6960 型プローブ D-MAX フットプリ ント用スクエア・ピン・ヘッダ・アダプタ
NEX-P6960PIN
仕様
表 1: 電気仕様と機械仕様
特性 説明
入力チャンネル
入力抵抗
入力キャパシタンス
入力信号スイング
最小値
最大値
最大非破壊 入力信号
スレッショルド電圧
検出可能な最小パル ス幅
最大入力トグル・レー ト
デジタル・チャン ネル間スキュー
プローブ長
デジタル 16 チャンネル
100 kΩ ±1.0%
3.0 pF
400 mVp-p
30 V p-p、≤200 MHz (プロー ブ・チッ プで DC スレッショルド電圧を中心に)
10 V p-p、≥200 MHz (プロー ブ・チッ プで DC スレッショルド電圧を中心に)
30 V p-p、42 V ピーク、±50 VDC
±40 V
1ns
500 MHz
200 ps
1.0m(3.28フィート)
表 2: 環境仕様
特性 説明
温度
動作時 非動作時
湿度
動作時 非動作時
高度
動作時 非動作時
0~+50℃ –55 ~ +75 ℃
相対湿度 5 ~ 95% 相対湿度 10 ~ 95%
最高 4.6 Km(15,092 フィ ート) 最高 15 Km(50,000 フィート)
機器のリ 2002/96/EC (廃棄電気・電子機器に関する指 令)に基づく EU の諸要件に準拠しています。リ サイクル方法の詳細については、当社 Web サ イト(www.tektronix.com)の「Support/Service」を 参照してください。
サイクル本製品は WEEE Directive
安全にご使用いただくために
接続と切断の手順を守ってください: 測定対象の回路にプ
ローブを接続する前に、プローブ出力を計測機器に接続し てください。計測機器からプローブを外す前に、測定対象の 回路からプローブの入力とグランドを外してください。
プローブとオシロスコープの接続
以下の図に示すようにプローブを接続します。
1. ラベル面を上にして、プローブをオシロスコープのコネ クタに挿入します。
2. プローブを取り外すには、両サイドのボタンを押してプ ローブを引き抜きます。
プローブと測定回路の接続
ローブを回路に接続するには、本書の末尾に記載されて
プ いるコネクタとアダプタを使用します。最適な方法を選んで、
の「プローブのセットアップ」に記載された指示に従ってく
次 ださい。
x
アクセサリ
本プローブには下記の表に示すスタンダード・アクセサリが 付属しています。後の図を参照してください。
説明 数量 部品番号
ロジック・プローブ・アク
セサリ・キット
1
延長グランド・チップ
2
プローブ・チップ
3
IC グラバ
4
プローブ・チップ・ホルダ 2 個
5
8インチ・グランド・リード
6
3インチ・グランド・リード
取扱説明書
1
取扱説明書はプローブに付属しています。アクセサリ・キットにはあ りません。 取扱説 明書は www.tektronix.com/manuals からダウンロ ードするこ とができます。
1
項目 1–6
20 本入り セット
10 本入り セット
20 本入り セット
2 本入りセッ ト
8 本入りセッ ト
1個
020-2662-XX
020-2711-XX
131-5638-11
020-2733-XX
352-1115-XX
020-2713-XX
020-2712-XX
071-2831-XX
すべての端子の定格に従ってください: 火災や感電の危険 を避けるために、本製品のすべての定格とマーキングに従っ てください。本製品に電源を接続する前に、定格の詳細につ いて、製品マニュアルを参照してください。
カバーを外した状態では使用しないでください: 電源が投入 されているときに、露出した接続部分や部品に触れないでく ださい。
回路の露出を避けてください: 電源が投入されているときに、 露出した接続部分や部品に触れないでください。
故障の疑いがあるときは使用しないでください: 本製品に 故障の疑いがある場合、資格のあるサー ビス担当者に検査 してもらってください。
湿気の多いところでは使用しないでください: 爆発しやすい 環境では動作させないでください。
製品の表面を清潔で乾燥した状態に保ってください:
安全に関する用語と記号
このマニュアルでは次の用語を使用します。
警告: 人体や生命に危害をおよぼすおそれのある状態
や行為を示します。
注意: 本製品やその他の接続機器に損害を与えるおそ
れのある状態や行為を示します。
本製品の記号: 本製品は以下の記号に注意してご使用くだ さい。
Tektronix 連 絡先
Web サイト:
電話番号:
http://www.tektronix.com
1-800-833-9200
Loading...
+ 5 hidden pages