Tektronix P6133 User manual

Instruction Manual
P6133 10X Passive Probe for 2400 Series Oscilloscopes
070-5795-04
Warning
www.tektronix.com
*P070579504*
070579504
Copyright © T ektronix, Inc. All rights reserved. T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved. T ektronix, Inc., P.O. Box 500, Beaverton, OR 97077 TEKTRONIX and TEK are registered trademarks of T ektronix, Inc.

WARRANTY

T ektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of purchase from an authorized T ektronix distributor. If any such product proves defective during this warranty period, T ektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty .
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by T ektronix, shipping charges prepaid, and with a copy of customer proof of purchase. T ektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the T ektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. T ektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than T ektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-T ektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE LISTED PRODUCTS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUST OMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT , SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Contacting Tektronix

Product support
Service support
For other information
To write us
Web site
For questions about using T ektronix measurement products, call toll free in North America: 1-800-833–9200 6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail: tm_app_supp@tek.com
For product support outside of North America, contact your local T ektronix distributor or sales office.
T ektronix offers extended warranty and calibration programs as options on many products. Contact your local T ektronix distributor or sales office.
For a listing of worldwide service centers, visit our web site. In North America:
1-800–833–9200 An operator can direct your call.
T ektronix, Inc. P.O. Box 500 Beaverton, OR 97077-1000 USA
www .tektronix.com

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.

To Avoid Fire or Personal Injury

Symbols and Terms

Connect and Disconnect Properly . Do not connect or disconnect probes or test
leads while they are connected to a voltage source. Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings
and markings on the product. Consult the product manual for further ratings information before making connections to the product.
The common terminal is at ground potential. Do not connect the common terminal to elevated voltages.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel.
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry .
T erms in this Manual. The following terms may appear in this manual:
P6133 Instruction Manual
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
i

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures. Do Not Service Alone. Do not perform internal service or adjustments to this
product unless another person capable of rendering first aid and resuscitation is present.
ii
P6133 Instruction Manual

Operating Basics

The P6133 probe is a 150 MHz, 10X, 2 meter, passive voltage probe designed specifically for use with Tektronix 2400 Series oscilloscopes having bandwidths less than or equal to 150 MHz.
The P6133 standard probe comes with a 2 meter cable length (1.3 meter length is also available) and the Tektronix Subminiature probe tip/hybrid assembly, which is fully compatible with the Tektronix Subminiature family of accessories.
The P6133 Option 25 probe comes with the Compact Series probe tip/hybrid assembly and is available in 1.3 meter length only. The Compact size probe tip/hybrid assembly is slightly larger in diameter than the Subminiature, offering greater durability and ruggedness in those environments and applications where required. The Compact tip is not compatible with the Subminiature series and is supplied with its own accessories.
Optional accessories are available for both tip sizes. You can also convert the Subminiature and Compact probe tip/hybrid assemblies to the Tektronix Miniature series probe tip by using the subminiature/compact-to-miniature probe tip adapter (see the optional accessories sections for the individual probe types).

Probe Compensation

WARNING. To avoid electric shock when using the probe, do not touch the metallic portions of the probe head while connected to a voltage source.
Due to variations in oscilloscope input characteristics, probe low-frequency compensation should be checked and or adjusted if you move the probe from one oscilloscope input to another. Connect the probe tip to a 1 kHz square wave signal (such as the oscilloscope calibrator output) and use a nonconductive low-reactance alightment tool to adjust the probe compensation capacitor.
See page 9 for complete low-frequency and high-frequency compensation adjustment procedures.
P6133 Instruction Manual
1
Operating Basics

Inductive Effects of Probe Grounding

Ground lead inductance can significantly reduce the performance of a probe. As shown in Figure 1, the ground lead inserts inductance into the signal path forming a series-resonant circuit with the probe input capacitance C
R
as damping. This forms a resonant circuit with f
source
V
source
R
source
Probe R
Ground lead
inductance
10 MW
and
in
+ 1 B (2p LCǸ).
0
Probe C
in
in
Typ. 10 pF
Figure 1: Circuit model: test point and probe input
A six-inch ground lead has approximately 150 nH of inductance, which produces
of approximately 130 MHz within the frequency response of the instru-
an f
0
ment. This greatly degrades rise time, bandwidth, and transient accuracy as shown in Figure 2.
Figure 2: Step response with six-inch ground lead
For best results, ensure that ground lead inductance is at a minimum.
2
P6133 Instruction Manual
Operating Basics
Low-Inductance Ground
Lead
The low-inductance ground lead provided with all Tektronix P6133 probes allows for a substantial reduction in ground-lead inductance, approximately 32 nH instead of 150 nH.
To install the low-inductance ground lead, refer to Figure 3 and perform the following steps:
1. Unscrew and remove the ribbed-tip shell and slide off the ground collar with
ground lead.
2. Slip on the low-inductance ground lead collar (1) and reinstall the ribbed
plastic tip cover.
3. Install the low-inductance lead (2) from the accessory pack.
1
2
Figure 3: Low-inductance ground lead
P6133 Instruction Manual
3
Loading...