Tektronix P6112 User manual

Instructions

P6112 100 MHz 10X Passive Probe
070-9694-00
Copyright T ektronix, Inc. All rights reserved. T ektronix products are covered by U.S. and foreign patents, issued and
pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. T o avoid potential hazards, use product only as specified.
Only qualified personnel should perform service procedures.
Injury Precautions
Avoid Electric Overload. To avoid injury or fire hazard, do not apply
potential to any input, including the common inputs, that varies from ground by more than the maximum rating for that input.
Avoid Electric Shock. To avoid injury, do not connect or disconnect
probes or test leads while they are connected to a voltage source.
Do Not Operate in an Explosive Atmosphere. To avoid injury or fire
hazard, do not operate this product in an explosive atmosphere.
Keep Probe Surface Clean and Dry. To avoid electric shock and
erroneous readings, keep probe surface clean and dry.
Product Damage Precautions
Do Not Operate With Suspected Failures. If you suspect there is damage
to this product, have it inspected by qualified service personnel.
Do Not Immerse in Liquids. Clean the probe using only a damp cloth.
Refer to Cleaning Instructions, page ii.
Safety Terms and Symbols
Terms in This Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
P6112 Instructions
i
General Safety Summary
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. These symbols may appear on the product:
DANGER
High Voltage
Protective Ground
(Earth) T erminal
ATTENTION
Refer to Manual
Certifications and Compliances
Compliances. Consult the product specifications for Overvoltage
Category and Safety Class.
Overvoltage Category. Overvoltage categories are defined as follows:
CAT III: Distribution level mains, fixed installation CAT II: Local level mains, appliances, portable equipment CAT I: Signal level, special equipment or parts of equipment,
telecommunication, electronics
Cleaning Instructions
Clean the probe using a soft cloth dampened with a mild detergent and water solution. Do not use any other chemicals or abrasives.
ii
P6112 Instructions

Features and Accessories

The P6112 Passive Probe is designed for use with a TDS 200 series oscilloscope that has a bandwidth of 100 MHz or less.
The P6112 Passive Probe is listed with Underwriters Laboratories Inc. and meets the requirements of UL 3111–1, ground referenced.
NOTE. Remove and discard the protective cover on the tip of the probe before attempting to connect a probe tip accessory.
P6112 Features and Standard Accessories
BNC-to-Probe Tip Adapter – To install the adapter, push the wide
end firmly into a BNC connector. Then, insert the probe tip firmly into the adapter.
Retractable Hook Tip – Use the retractable hook tip to make
hands-free measurements.
NOTE To ensure a proper connection, firmly twist the hook tip onto the
probe.
Unlocked Locked
P6112 Instructions
Marker Rings – To identify probe connections, attach matching
colored rings onto the probe cable and tip as shown.
Locking Connector – Install the connector in the unlocked position
and turn it clockwise until it snaps into the locked position.
1
Features and Accessories
P6112 Features and Standard Accessories (Cont.)
Ground Lead – Use the alligator clip to attach the probe to a ground
reference. Attach matching marker ring as shown.
Adjustment Tool – Use the adjustment tool for probe compensation
adjustments.
Long Ground Lead
Short Ground Lead
T o see the best signal, use the shortest possible ground lead and signal path.
2
P6112 Instructions

Probe Compensation

Before taking any measurements using a probe, first check the compensation of the probe and adjust the probe compensation to match the channel input the probe is connected to.
NOTE. If you use a hook tip, ensure a proper connection by firmly twisting the hook tip onto the probe.
1. Connect the probe to the Probe Comp signal on your TDS 200 series oscilloscope and then press AUTOSET.
PROBE
COMP
2. Compensate the probe by adjusting the trimmer on the probe so that the corners of the signal are square.
AUTOSET
button
CH 1
1 kHz
Trimmer
P6112 Instructions
3

Specifications

The characteristics listed in T able 1 apply to a P6112 Passive Probe installed on a Tektronix TDS 220 oscilloscope unless otherwise noted.
These specifications apply when the instrument has had a warm-up period of at least 10 minutes and is in an environment that does not exceed the limits described in T able 2.
Table 1: Electrical characteristics
Attenuation (DC coupled system)
Input resistance (DC coupled system)
Input capacitance 11.8 pF to 14.8 pF
Compensation range 15 pF to 35 pF Rise time
(DC coupled system) Bandwidth
(–3 dB, DC coupled system) Maximum Working (Nondestructive)
Input Voltage (For frequency derating curve, refer to Figure 1 on page 6)
Safety UL3111–1, First Edition
10X"2% at DC
10 M"1.5%
(13.3 pF typical)
3.5 ns (TDS 220)
5.8 ns (TDS 210) DC to 100 MHz (TDS 220)
DC to 60 MHz (TDS 210)
Overvoltage Category
Category I Category II
CSA C22.2 No. 1010.1–92 EN61010–1 EN61010–2–031 Overvoltage Category II, Pollution Degree 2
Maximum Voltage
300 V
RMS
300 V
RMS
4
P6112 Instructions
Specifications
and Environmental
aracteristi
Table 1: Electrical characteristics (Cont.)
EC Declaration of Conformity Compliance was demonstrated to the following
specification as listed in the Official Journal of the European Communities:
Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC:
EN 61010-1 Safety requirements for
electrical equipment for measurement, control, and laboratory use
EN 61010-2-031:1994 Particular requirements
for hand-held probe assemblies for electrical measurement and test
Table 2: Physical
Net Weight (including accessories)
Cable Length 2 meters (78.74 in) Temperature Range
Operating
Nonoperating
Humidity
1
1
Tektronix Standard 062-2847-00, class 3. Refer to MIL-E-16400F, paragraph
1
Ch
110 g (0.243 lb)
–15° C to +55° C (+5° F to +131° F)
–62° C to +85° C (–80° F to +185° F)
Tested at 95% to 97% relative humidity (30°C to 55°C)
cs
4.5.9 through 4.5.9.5.1, class 4.
P6112 Instructions
5
Specifications
400V 300V
200V 100V
Voltage
)
(V
RMS
10V
Category I & II
0
Frequency (Hz)
10M 100M1M
5M 50M
Figure 1: Maximum Working V oltage Derating Curve (V
6
, DC Coupled)
RMS
P6112 Instructions

Replaceable Parts

2
1
3
Standard Accessories
7
Figure 2: P6112 Replaceable Parts
4
8 9
Optional Accessories
5
6
P6112 Instructions
7
Replaceable Parts
Serial No.
Serial No.
Tektronix
Fig. &
Replaceable Parts List
Index
STANDARD ACCESSORIES
Qty Name & Description Mfr. Code Mfr. Part Number
Discont’d
Effective
Part Number
Number
2– ––––––––––– 1 PROBE,PASSIVE:P6112
–1 013–0107–07 2 TIP,PROBE:MINIATURE/COMPACT SIZE,GREY TK2565 013–0107–07
–2 See Opt. Acc 1 CONTACT,ELEC:PROBE TIP W/INSULATOR ASSY
–3 196–3120–01 2 LEAD,ELECTRICAL:PROBE GND,6.0 L 80009 196–3120–01
–4 016–0633–00 1 MARKER SET,CA:2 EA VARIOUS COLORS 80009 016–0633–00
–5 See Opt. Acc. 1 SCREWDRIVER:ADJUSTMENT T OOL
–6 013–0277–00 1 ADAPTER,CONN:BNC TO MINIATURE PROBE TIP 24931 33A129–1
OPTIONAL ACCESSORIES
070–9694–00 1 MANUAL,TECH:INSTR, P6112, DP 80009 070–9694–00
–2 131–4997–01 1 CONTACT,ELEC:2 TIP–INSULATOR W/INFO CARD 80009 131–4997–01
–5 003–1433–01 1 SCREWDRIVER:ADJUSTMENT TOOL,PKG OF 5 80009 003–1433–01
–7 196–3120–21 1 LEAD,ELECTRICAL:PROBE GND,28.0 L 80009 196–3120–21
–8 196–3121–01 1 LEAD,ELECTRICAL:PROBE GND,12.0 L 80009 196–3121–01
P6112 Instructions8
013–0107–07 1 TIP,PROBE:MINIATURE/COMPACT SIZE,GREY TK2565 013–0107–07
–9 015–0201–07 1 TIP,PROBE:IC TEST,PKG OF 10 80009 015–0201–07
Replaceable Parts
FRANKLIN, IN 46131
BEAVERT ON, OR 97077–0001
2100 EARLYWOOD DR
PO BOX 547
PO BOX 500
Manufacturer Address City , State, Zip Code
Mfr.
Manufacturers Cross Index
Code
24931 BERG ELECTRONICS INC BERG ELECTRONICS RF/COAXIAL DIV
TK2565 VISION PLASTICS INC 26000 SW PARKWAY CENTER DRIVE WILSONVILLE, OR 97070
80009 TEKTRONIX INC 14150 SW KARL BRAUN DR
P6112 Instructions 9
Replaceable Parts
P6112 Instructions10
WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of purchase from an authorized Tektronix distributor. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE LISTED PRODUCTS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Loading...