Tektronix P5910 User manual

xx
P5910
ZZZ
General Purpose Logic Analyzer Probe
Instruction Manual
www.tektronix.com
P077063501*
*
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worl dwid e, visi t www.tektronix.com to nd contacts in your area.
Warranty
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be n the property of Tektronix.
ew or reconditioned to like new performance. All replaced parts, modules and products become
In order to o the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage result b) to repair damage resulting from improper use or connection t o incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modied or integrated with other products when the effect of such modication or integration increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
TRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE
TEK AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
[W2 – 15AUG04]
btain service under this warranty, Customer must notify Tektronix of the defect before the expiration of
ing from attempts by personnel other than Tektronix representatives to install, repair or service the product;
Table of Contents
General safety summary ...................... ................................ .................................. .. iii
Service safety summary............................................................................................ v
Compliance information .......................................................................................... vi
Safety comp
Environmental considerations .............................................................................. vii
Preface .............................................................................................................. ix
Related documentation......................... ................................ .............................. ix
Operating basics ..................... ................................ ................................ ............... 1
Product description ..................... ................................ ................................ ....... 1
P5910 pr
Probe label overview ................. .................................. ................................ ....... 3
Apply the labels to the probe .............. ................................ .................................. . 4
Accessory kit information ........... ................................ .................................. ....... 5
Install the probe grouper ..... .................................. ................................ ............... 7
Connect the probe to the instrument................ .................................. ....................... 8
ect the probe to the SUT ........... .................................. ................................ ... 9
Conn
Reference ............... .................................. ................................ .......................... 11
Probe footprints............................................................................................... 11
Load model .................................................................................................... 12
Probe dimensions ......... ................................ ................................ .................... 13
Specications........................ ................................ ................................ .......... 14
intenance........................................................................................................ 17
Ma
P5910 probe calibration information ............. .................................. ........................ 17
P5910 probe service strategy information ........... ................................ ...................... 17
Perform the functional check .................... ................................ ............................ 17
Inspect or clean the probe................ .................................. ................................ .. 18
Repackage the probe ......................................................................................... 18
Replaceable parts .................................................................................................. 19
Parts ordering information ................................................................................... 19
Glossary
Index
liance ............................................................................................ vi
obe accessory information ......................................................................... 2
P5910 General Purpose Probe Instruction Manual i
Table of Contents
List of Figure
Figure 1: Example of a sheet of P5910 probe labels .............. .................................. ........... 3
Figure 2: At
Figure 3: Accessory kit contents..................................... ................................ ............. 6
Figure 4: Install the probe leads through the probe grouper .............................. ..................... 7
Figure 5: Align the probe leads...... .................................. ................................ ........... 7
Figure 6: Slide the probe grouper over the leads and engage the retention tangs into the notches . ..... . . 7
Figure 7: Connect the probe to the logic analyzer . ................................ ............................. 8
Figure 8:
Figure 9: Dimensions of 8-channel probe footprint with probe grouper attached........................ .. 11
Figure 10: P5910 grouping footprint (16-data channels plus one clock).................................... 12
Figure 11: P5910 probe loading and equivalent circuit ........... ................................ ............ 12
Figure 12: P5910 probe dimensions....... ................................ ................................ ...... 13
List o
fTables
taching the probe labels ........ ................................ .................................. ... 5
Pin spacing between 8-channel groups and clock/qualier leads................................. 11
s
Table 1: Accessory kit contents.............................. .................................. ................... 6
le 2: Mechanical and electrical s pecications............ ................................ .................. 14
Tab
Table 3: Environmental specications ........ ................................ .................................. 15
Table 4: Service options ............ ................................ ................................ .............. 17
ii P5910 General Purpose Probe Instruction Manual
General safety summary
General safet
To avoid re or personal
injury
y summary
Review the fo this product or any products connected to it.
To avoid pot
Only qualied personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions r
Ground the product. This product is indirectly grounded through the grounding conductor of the mainframe power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly ground
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and ma information before making connections to the product.
The i
ed.
nputs are not rated for connection to mains or Category II, III, or IV circuits.
llowing safety precautions to avoid injury and prevent damage to
ential hazards, use this product only as specied.
elated to operating the system.
rkings on the product. Consult the product manual for further ratings
Connect the probe reference lead to earth ground only.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not operate without covers. Do not operate this product with covers or panels removed.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by qualied service personnel.
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
P5910 General Purpose Probe Instruction Manual iii
General safety summary
Termsinthismanual
Symbols and terms on the
product
Do not operate i
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
These terms
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
These terms may appear on the product:
DANGER the marking.
WARNI read the marking.
CAUT
n wet/damp conditions.
may appear in this manual:
indicates an injury hazard immediately accessible as you read
NG indicates an injury hazard not immediately accessible as you
ION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
iv P5910 General Purpose Probe Instruction Manual
Service safety summary
Service safet
ysummary
Only qualifie safety summary and the General safety summary before performing any service procedures.
Do not service alone. Do not perform internal service or adjustments of this product unless another person capable of rendering rst aid and resuscitation is present.
Disconnect power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use care when servicing with power on. Dangerous voltages or currents may exist in this p test leads before removing protective panels, soldering, or replacing components.
To avoi
d personnel should perform service procedures. Read this Service
roduct. Disconnect power, remove battery (if applicable), and disconnec t
d electric shock, do not touch exposed connections.
P5910 General Purpose Probe Instruction Manual v
Compliance information
Compliance in
Safety compliance
Equipment type
Safety class
Pollution
degree
description
formation
This section instrument complies.
Test and measuring equipment.
Class 1 – grounded product.
A measure of the contaminants that could occur in the environment around and within a product. Typically the internal environment inside a product is considered to be the same as the external. Products should be used only in the environ
Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Produc located in clean rooms.
lists the safety and environmental standards with which the
ment for which they are rated.
ts in this category are generally encapsulated, hermetically sealed, or
ollution degree
P
tion Degree 2. Normally only dry, nonconductive pollution occurs.
Pollu Occasionally a temporary conductivity that is caused by condensation must be expected. This location is a typical ofce/home environment. Temporary condensation occurs only when the product is out of service.
Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation. These are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct sunshine, rain, or direct wind.
Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, o r snow. Typical outdoor locations.
Pollution Degree 2 (as dened in IEC 61010-1). Note: Rated for indoor use only.
vi P5910 General Purpose Probe Instruction Manual
Environmental considerations
This section provides information about the environmental impact of the product.
Compliance information
Product end-of-life
handling
Restriction of hazardous
substances
Observe the f
Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product’s end of life. To avoid release of such substances into the environment and to reduce the an appropriate system that will ensure that most of the materials are reused or recycled appropriately.
This pr scope of the 2002/95/EC RoHS Directive.
ollowing guidelines when recycling an instrument or component:
use of natural resources, we encourage you to recycle this product in
This symbol indicates that this product complies with the applicable European Union re on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tekt r on
oduct is classied as Monitoring and Control equipment, and is outside the
quirements according to Directives 2002/96/EC and 2006/66/EC
ixWebsite(www.tektronix.com).
P5910 General Purpose Probe Instruction Manual vii
Compliance information
viii P5910 General Purpose Probe Instruction Manual
Loading...
+ 25 hidden pages