Tektronix products are covered by U.S. and foreign patents, issued and
pending. Information in this publication supercedes that in all previously
published material. Specifications and price change privilege s reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX, TEK, and NetTek are registered trademarks of Tektronix, Inc.
WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects
in materials and workmanship for a period of one (1) year from the date of purchase from
an authorized Tektronix distributor. If any such product proves defective during this
warranty period, Tektronix, at its option, either will repair the defective product without
charge for parts and labor, or will provide a replacement in exchange for the defective
product. Batteries are excluded from this warranty.
In order to obtain service under this warranty, Customer must notify Tektronix of the
defect before the expiration of the warranty period and make suitable arrangements for the
performance of service. Customer shall be responsible for packaging and shipping the
defective product to the service center designated by Tektronix, shipping charges prepaid,
and with a copy of customer proof of purchase. Tektronix shall pay for the return of the
product to Customer if the shipment is to a location within the country in which the
Tektronix service center is located. Customer shall be responsible for paying all shipping
charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or
improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish
service under this warranty a) to repair damage resulting from attempts by personnel other
than Tektronix representatives to install, repair or service the product; b) to repair damage
resulting from improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a
product that has been modified or integrated with other products when the effect of such
modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE
LISTED PRODUCTS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE
DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY
PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY.
TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY
INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS
ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table of Contents
General Safety Summaryv............................
Standard AccessoriesD--1.................................
Components And AccessoriesD--1..........................
Index
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
iii
Table of Contents
iv
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent
damage to this product or any products connected to it. To avoid
potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the
system. Read the General Safety Summary in other system manuals
for warnings and cautions related to operating the system.
WARNING. To avoid injury, do not connect this product to any source
which may be subject to the effects of lightning. See page 1--20 for
complete information.
To Avoid Fire or Personal Injury
Use Proper Power Cord. Use only the power cord specified for this
product and certified for the country of use.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all
ratings and markings on the product. Consult the product manual for
further ratings information before making connections to the product.
Replace Batteries Properly. Replace batteries only with the proper type
and rating specified.
Recharge Batteries Properly. Recharge batteries for the recommended
charge cycle only.
Use Proper AC Adapter. Use only the AC adapter specified for this
product.
Do Not Operate W ithout Covers. Do not operate this product with
covers or panels removed.
Avoid Exposed Circuitry. Do not touch exposed connections and
components when power is present.
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
v
General Safety Summary
Wear Eye Protection. Wear eye protection if exposure to high-intensity
rays or laser radiation exists.
Do Not Operate With Suspected Failures. If you suspect there is damage
to this product, have it inspected by qualified service personnel.
Do Not Operate in an Explosive Atmosphere.
Safety Terms and Symbols
Terms in This Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that
could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that
could result in damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you
read the marking.
WARNING indicates an injury hazard not immediately accessible as
you read the marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. These symbols ma y appear on the product:
CAUTION
Refer to Manual
vi
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
General Safety Summary
Battery Recycling
The NetTek Analyzer Platform uses rechargeable lithium-ion
batteries. Please consult your local government regulations for the
recycling or disposal of lithium-ion batteries.
Transporting Lithium-Ion Batteries
Each NetTek Analyzer Platform lithium-ion battery pack contains
less than 8 grams of lithium, with individual cells each containing
less than 1.5 grams of lithium, as measured by International Civil
Aviation Organization (ICAO) standards.
Regulations regarding transportation of lithium-ion batteries on
passenger aircraft may subject this product to special handling
restrictions. Consult your air carrier for applicability and determination of any special lithium-ion battery transportation requirements.
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
vii
General Safety Summary
viii
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Preface
This manual contains setup and operating instructions for the NetTek
YBT1E1 T1 & E1 Circuit Tester.
About This Manual
This manual is divided into four sections: Getting Started, Operating
Basics, Reference,andAppendices.
The Getting Started section explains how to install and start up your
T1 & E1 Circuit Tester.
The Operating Basics section explains how to operate the tester.
The Reference section explains how to perform tests.
The Appendices contain reference information you might need
occasionally, such as specifications or diagnostic procedures.
Online Help Information
The NetTek YBT1E1 onl ine help provides detailed information on
operating the tester. The online help is the first place you should look
for information.
The NetTek YBT1E1 tester runs on the NetTek Analyzer Platform.
You will find important information on c onfiguring a nd opera ting
this platform in theNetTek Analyzer Platform online help.
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
ix
Preface
Conventions
This manual uses the following convention to document the
commands you must use to operate the NetTek YBT1E1 T1 & E1
Circuit Tester..
The statement Start > Help is asking you to open the Start menu and
select Help. To accomplish this, tap the Start button in the toolbar at
the bottom of the desktop window; then tap Help in the resulting
menu.
Software Version
This manual supports products running YBT1E1 T1 and E1 Circuit
Tester, Option T1 and Option E1 software Version 2.100 and above.
To vie w your software version, do the following:
1. In the toolbar at the top of the startup screen, select Tools.
2. Select Software Info from the menu to display the software
information, including version number.
x
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Contacting Tektronix
Phone1-800-833-9200*
AddressTektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Web sitewww.tektronix.com
Preface
Sales
support
Service
support
Technical
support
*This phone number is toll free in North America. Af ter office hours,
please leave a voice mail message.
Outside North America, contact a Tektronix sales office or dist ributor;
see the Tektronix web site for a list of offices.
1-800-833-9200, select option 1*
1-800-833-9200, select option 2*
www.tektronix.com/support
1-800-833-9200, select option 3*
6:00 a.m. -- 5:00 p.m. Pacific St andard Time
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
xi
Preface
xii
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Getting Started
Getting Started
This section provides the information you need to set up and operate
theNetTekYBT1E1T1&E1CircuitTester.
The NetTek Analyzer Platform
The YBT1E1 Tester operates on the NetTek Analyzer Platform.
Figure 1--1 shows the NetTek Analyzer Platform layout. Figure 1--2
on page 1--2 shows the front-panel controls and indicators.
Batteries
Application
modules
Touch
Screen
External
power
Front panel
I/O ports
PC card
slots
Figure 1- 1 : NetTek Analyzer Layout
CAUTION. Only use soft objects, such as plastic or your finger, to tap
the touch-screen display. Do not use metal or other abrasive
materials because they wi ll damage the display surface.
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
1- 1
Getting Started
Figure 1- 2: Front Panel Controls
1. Power/Suspend Switch. Powers on or off the instrument. Push
on; push off. See pages 1--14 and 1--18 for additional informa tion.
2. Reset Switch. Push to perform a hardware reset if a lock-up
occurs. All programs and data loaded into volatile memory since
startup are lost.
123 4
3. Status Indicator. Green indicates that the instrument is powered
on. Amber indicates that the instrument is powered on but the
display is turned off (for power conservation).
4. Batteries Indicator. Green indicates that the instrument is
connected to an external power source (and charging any
installed batteries). Red indicates a low battery.
1- 2
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Getting Started
YBT1E1 T1 & E1 Circuit Tester Product Description
The NetTek YBT1E1 T1 & E1 Circuit Tester is part of the NetTek
BTS Field Tool family: a high
tester, optimized for rapid troubleshooting and ba se station
performance verification.
The NetTek YBT1E1 compliments the functionality of the NetTek
YBT250 Field Transmitter and Interference Tester and the NetTek
YBA250 Antenna and Transmission Li ne Analyzer, which also
operate on the NetTek Analyzer Platform.
Use the NetTek YBT1E1 to verify the proper operation of T1 and E1
data lines by verifying synchronization, line framing, bit errors, and
other important characteristics. The NetTek YBT1E1 circuit tester
can perform measurements on both in-service and out-of-service
networks.
monitoring (110 Ω)
terminating (110
bridging (>1 k
Ω)
Ω)
Signal level in dBdsx,
and V
120
for 75 Ω and
p-p
Ω impedances
Components and Accessories
For a complete list of accessories, see Appendix D, Acce ssories.
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
1- 5
Getting Started
Installing the YBT1E1 PC Card and Line Interface
See Figures 1--4 through 1--7 for how to assemble and install the
YBT1E1 Tester components.
YBT1E1
PC card
Connector fits only one way
into PC card: do not force
T1E1 Line Interface
Figure 1- 4: Connect the T1E1 Line Interface to the YBT1E1 Tester
1- 6
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Install the NetTek YBT1E1
PC card in the rear slot.
Access door
Getting Started
YBT1E1 PC card label faces
towards screen-side of instrument
Figure 1- 5: Installing the YBT1E1 PC card in the NetTek Analyzer
CAUTION. To meet the electromagnetic emissions standards specified
for this product, install the NetTek YB T1E 1 PC card in the rear slot
of the NetTek Analyzer Platf orm. See Figure 1--5.
Do not install any other PC card while using the NetTek YBT1E1
card.
NOTE. To remove the YBT1E1 PC card, press in the button located at
the top edge of the PC card slot, and then pull out the PC card.
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
1- 7
Getting Started
Secure the line interface to the side
of the NetTek Analyzer Platform
with hook-and-loop fastener strips.
Attach fastener
strips here.
1- 8
Figure 1- 6 : Attaching the line interface to the NetTek Analyzer Platform
Connect an RJ48 test cable
totheT1E1LineInterface
Figure 1- 7: Connecting the NetTek YBT1E1 components
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Connecting External Power Supplies
To power the NetTek Analyzer Platform from AC mains or DC
vehicle voltage, or recharge instal led batteries, connec t t he Desktop
Power Supply or the In-Vehicle Adapter to the NetTek Analyzer
Platform as shown in Figure 1--8. The Desktop Power Supply
operates from 100 VAC to 240 VAC mains.
Getting Started
Figure 1- 8: External power supplies
Power adapter connector
(under bottom of strap)
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
1- 9
Getting Started
Batteries
Installing or Removing a Battery
The NetTek Analyzer Platform comes standard with a single battery,
which is not installed when the instrument is shipped. The
instrument can use two batteries. Refer to Figures 1--9 through 1--11
for battery installation or removal steps.
NOTE. Disconnect t he power supply cables from the NetTek Analyzer
Platform before installing or removing batteries.
New batteries, or batteries that have not been used for an extended
period, must be charged before using them to power the instrument.
Refer to Charging a Battery on page 1--12 for more information.
1- 10
Figure 1- 9: Opening the battery compartment
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
1. Push the battery
retainer tab down and
towards the back of
instrument, then lift
Getting Started
2. Rotate the
battery retainer
upward
Figure 1- 10: Opening the battery retainer
Lift battery by the strap
Install battery in
either slot
Battery retainer
in open position
Figure 1- 11: Installing/removing a battery
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
1- 11
Getting Started
NOTE. The battery electrical contacts, on the bottom of the battery,
must face in the direction shown in Figure 1--11 on page 1-- 11.
Close and latch the battery retainer and battery compartment door
after installing or removing batteries.
You can add a second battery to increase the operating time. Replace
a battery with the specified type only. To purchase a battery from
Tektronix, please conta ct your Tektronix Service Center for the
correct part number.
Charging a Battery
To charge batteries installed in the NetTek Analyzer Platform,
connect the instrument to an external power supply (see Figure 1--8
on page 1--9) and let the battery or batteries recharge in the
instrument. Table 1-- 2 lists the approximate charge times for
fully--discharged batteries. You can also charge batteries in the
optional external battery charger.
Table 1 - 2: Approximate battery charge times
Number of batteries in
instrument
112 hours4.5 hours
224 hours9 hours
Instrument powered
on
Instrument powered
off
NOTE. To achieve optimum performance from a new battery, fully
charge the battery. Then fully discharge the battery by leaving the
software running (see Start > Help > Settings > Power Management
for information on disabling the power saver function), then fully
charge the battery again.
1- 12
NetTek YBT1E1 T1 & E1 Circuit Tester User Manual
Loading...
+ 92 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.