Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supercedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of T ektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to find contacts in your area.
Warranty 2
T ektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year
from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option,
either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange
for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new
or reconditioned to like new performance. All replaced parts, modules and products become the property of T ektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of
the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for
packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges
prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country
in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties,
taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage
resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to
repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or
malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated
with other products when the effect of such modification or integration increases the time or diff iculty of servicing the
product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF
MERCHANT ABILITY OR FITNESS FOR A P AR TICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY
TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY
PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS
VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS
ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table D-1: Pin assignment of the Universal In/Out connector . . . . . . . . D-1
viiiMTX100A MPEG Recorder & Player User Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to this
product or any products connected to it. To avoid potential hazards, use this
product only as specified.
Only qualified personnel should perform service procedures.
To Avoid Fire or
Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and
certified for the country of use.
Ground the Product. This p roduct is grounded thro ugh the grounding con ductor of
the power cord. To avoid electric shock, the grounding conductor must be
connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock ha zard, observe all ratings
and markings on the product. Consult the product manual for further ratings
information before making connections to the product.
Do Not Operate Without Covers. Do not operate this product with covers or panels
removed.
Use Proper Fuse. Use only the fuse type and rating specified for this product.
Avoid Exposed Circuitry. Do not touch exposed connections and components when
power is present.
Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
MTX100A MPEG Recorder & Player User Manualix
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
No Power Switch. The power supply cord is considered the disconnecting device,
disconnect the main power by means of the power cord.
General Safety Summary
Symbols and Terms
Terms in this Manual. These terms may appear in this manual:
WAR N I N G. Warning statements identify conditions or practices that could result in
injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the
marking.
WARNING indicates an injury hazard not immediately accessible as you read the
marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. The following symbols may appear on the product:
CAUTION
Refer to Manual
Protective Ground
(Earth) Terminal
xMTX100A MPEG Recorder & Player User Manual
Environmental Considerations
This section provides information about the environmental impact of the product.
Product End-of-Life
Handling
Observe the following guidelines when recycling an instrument or component:
Equipment Recycling. Production of this equipment required the extraction and use
of natural resources. The equipment may contain substances that could be harmful
to the environment or human health if improperly handled at the product's end of
life. In order to avoid release of such substances into the environment and to reduce
the use of natural resources, we encourage you to recycle this product in an
appropriate system that will ensure that most of the materials are reused or recycled
appropriately.
The symbol shown to the left indicates that this product
complies with the European Union's requirements according to
Directive 2002/96/EC on waste electrical and electronic
equipment (WEEE). For information about recycling options,
check the Support/Service section of the Tektronix Web site
(www.tektronix.com).
Mercury Notification. This product uses an LCD backlight lamp that contains
mercury. Disposal may be regulated due to environmental considerations. Please
contact your local authorities or, within the United States, the Electronics
Industries Alliance (www.eiae.org) for disposal or recycling information.
Restriction of Hazardous
Substances
MTX100A MPEG Recorder & Player User Manualxi
This product has been classified as Monitoring and Control equipment, and is
outside the scope of the 2002/95/EC RoHS Directive. This product is known to
contain lead, cadmium, mercury, and hexavalent ch romium.
Environmental Considerations
xiiMTX100A MPEG Recorder & Player User Manual
Preface
The user manual for the MTX100A MPEG Recorder & Player contains the
following sections:
Getting Started briefly describes the MTX100A MPEG Recorder & Player and
provides installation instructions, option and accessory lists, repacking
instructions, and power on and off instructions.
Operating Basics provides an overview of the front panel controls and rear panel
connections, operating principles, basic operating procedures, and numeric input
methods. This section also provides examples of basic data outputting and
recording.
Reference provides detailed information about the functions and use of the
MTX100A MPEG Recorder & Player’ s m ain menus, and presents descriptions of
all programming commands and the syntax used in command descriptions. This
section also provides instructions for setting the network parameters for the
Ethernet port.
Appendices provides product specifications, instructions for operating the ReMux
and Scheduler applications, defragging the hard disk, recovering the system, and
inspecting and cleaning the MTX100A MPEG Recorder & Player.
Term s
This manual uses the following terms:
Stream: Generic term for transport streams and data streams of Non TS format
(data format other than transport stream format).
S-TMCC (Single TMCC): Transport stream to which TMCC (Transmission
and Multiplexing Configuration Control) information is inserted into the
8 bytes in its Reed-Solomon code area (16 bytes). It is defined in the ISDB-S
(Integrated Services Digital Broadcasting-Satellite) system.
M-TMCC (Multi TMCC): Transport stream to which TMCC information is
inserted into the sync byte area, and having super frame structure. It is defined
in the ISDB-S system.
MTX100A MPEG Recorder & Player User Manualxiii
Preface
Related Manual
The following related documentation for the instrument is available:
The MTX100A MPEG Recorder & Player Service Manual (Tektronix part
number 071-1754-XX) describes how to maintain and service the MTX100A
and provides a complete module-level description of the operation of the
instrument. This manual is an optional accessory.
xivMTX100A MPEG Recorder & Player User Manual
Getting Started
Getting Started
Product Description
This section provides the following information:
Product description
List of standard and optional accessories
List of instrument options
Initial product inspection procedure
Installation instructions
Instructions for repackaging the instrument for shipment
Functional check procedure
Windows operations
The MTX100A MPEG Recorder & Player records and plays MPEG-2 transport
streams that are compliant with ATSC, DVB, and ARIB standards.
The MTX100A provides the following features:
Data rate: 214 Mbps maximum; 256 Kbps minimum
Hierarchy display of stored or captured transport stream
188, 204, 208 bytes packet size, S-TMCC, M-TMCC, non transport stream,
and partial transport stream output formats
Real-time updating of stream parameters; continuity_counter, PCR/P TS/DTS,
TOT/TDT/STT, NPT, and Reed Solomon (ISDB-T only)
Continuous recording of captured streams
PCR jitter insertion
Triggered stream capture
Full remote control using Ethernet interface
Scheduler application for automated stream playout and record (Option SC
only)
MTX100A MPEG Recorder & Player User Manual1-1
Getting Started
Standard Accessories
Optional ASI, universal parallel/serial, IEEE1394/ASI, and
SMPTE310M/ASI/SPI interfaces available
The MTX100A includes the ReMux application software that provides the
capability to create a transport stream of super frame structure defined in the
ISDB-S systems from an MPEG2 transport stream. Refer to Appendix B: Using ReMux Application for detailed information about the ReMux application.
NOTE. When inputting/outputting a stream for a long time, the stream may be
intermittent because of a processing condition of the hard disk or the system
process of Windows XP.
The following accessories are shipped with the MTX100A:
Document, CD-ROMs, and
Other Parts
The following document, CD-ROMs, and other parts are standard accessories:
MTX100A MPEG Recorder & Player User Manual.
English (Option L0): Tektronix part number 071-1731-XX.
Japanese (Option L5): Tektronix part number 071-1753-XX.
Windows XP Professional recovery DVD-ROM, Tektronix part number
063-3864-XX.
Sample Stream CD-ROM, Tektronix part number 063-3865-XX.
Application Software Recovery CD-ROM, Tektronix part number
063-3866-XX.
Interface cable (D-sub 25-pin, twisted pair), Tektronix part number
012-A220-00.
USB keyboard, Tektronix part number 119-B146-00.
USB mouse, Tektronix part number 119-B145-00.
Front cover, Tektronix part number 200-3897-00.
1-2MTX100A MPEG Recorder & Player User Manual
Getting Started
Power Cords
All MTX100A MPEG Recorder & Players are shipped with one of the following
power cord options. Power codes for use in North America are UL listed and CSA
certified. Cords for use in areas other than North America are approved by at least
one authority acceptable in the country to which the product is shipped.
Table 1-1: Power cord identification
Plug configurationNormal usageOption number
North America
115 V
Universal Euro
220 V
United Kingdom
240 V
Australia
240 V
Standard (A0)
A1
A2
A3
North America
250 V
Switzerland
240V
Japan
100 V
China
240 V
No power code supplied.A99
A4
A5
A6
A10
MTX100A MPEG Recorder & Player User Manual1-3
Getting Started
Optional Accessories
Options
The following items are optional accessories:
MTX100A MPEG Recor der & Player Service Manual, Tektronix part number
071-1754-XX.
WFM7F05 rackmount kit
1700F06 blank panel
The MTX100A can be ordered with the following options:
Instrument Options
Service Options
The following instrument options are available for the MTX100A:
Option 01: Adds the ASI interface.
Option 02: Adds the Universal Parallel/Serial interface.
Option 05: Adds the IEEE1394/ASI interface.
Option 07: Adds the SMPTE310M/ASI/SPI interface.
Option SC: Adds the Scheduler software.
The following service options are available for the MTX100A:
Option C3: Provides calibration services for 3 years.
Option C5: Provides calibration services for 5 years.
Option D1: Provides calibration data.
Option D3: Provides calibration data for 3 years.
Option D5: Provides calibration data for 5 years.
Option R3: Extends the instrument warranty to 3 years.
Option R5: Extends the instrument warranty to 5 years.
Power Cord Options
1-4MTX100A MPEG Recorder & Player User Manual
See Table 1-1 on page 1-3.
Initial Product Inspection
Perform the following product inspection procedure when you receive your
instrument:
1. Inspect the shipping carton for external damage, which indicates possible
2. Remove the MTX100A from the shipping carton.
3. Check that the instrument has not been damaged in transit. The exterior should
NOTE. Save the shipping carton and packaging materials for instrument
repackaging in case shipment becomes necessary.
4. Verify that the shipping carton contains the instrument, the standard
Getting Started
damage to the instrument.
not have any scratches or impact marks. Prior to shipment the instrument is
thoroughly inspected for mechanical defects.
accessories, and any optional accessories that you ordered.
Installation
Environment Operating
Requirements
5. Perform the functional check procedure (refer to Functional Check Procedur e
on page 1-10) after installing the instrument.
Contact your local Tektronix Field Office or representative if there is a problem
with your instrument or if your shipment is incomplete.
Before you install the instrument, refer to the General Safety Summary section at
the front of this manual for power source, grounding, and other safety information.
Verify that the location of your installation has the proper operating environment.
CAUTION. Damage to the instrument can occur if this instrument is powered on at
temperatures outside of the specified temperature range.
MTX100A MPEG Recorder & Player User Manual1-5
Getting Started
Table 1-2: Environmental operating requirements
CharacteristicsSpecifications
MTX100A ambient temperaturesfrom +5 °C to + 40 °C
MTX100A relative humidityfrom 20% to 80%
Clearance on top5.0 cm (2 in)
Clearance on left side5.0 cm (2 in)
Clearance on right side5.0 cm (2 in)
Clearance in rear (from the fan guard)5.0 cm (2 in)
NOTE. If you are installing the instrument in a dedicated rack, refer to the
instruction sheet that comes with the rackmounting kit for proper installation
procedures.
When the MTX100A is mounted in a 19-inch rack, verify that there is at least one
unit of clearance above the MTX100A.
AC Line Voltage
Requirement
Power Cord Requirement
Check that your location provides the proper electrical power requirements as
listed in Table 1-3.
Table 1-3: AC line power requirement
ParameterDescription
Line voltage range100 to 240 V
Line frequency50/60 Hz
Maximum power180 VA
CAUTION. The instrument does not have a power switch, but does have an
on/standby switch. When you connect the power cable to the AC line connector,
power is applied to the power supply standby circuit of the instrument. Read all
instructions on pages 1-7 and 1-8 before plugging the power cable into a power
source.
Refer to Table 1-1 on page 1-3 to verify that you are using the proper power
cord for your location. Connect the power cord from the rear-panel power
connector to the power system.
CAUTION. The instrument is shipped with a power cord appropriate for use with
your power systems (normal 115 V power system or 230 V power system). If the
instrument is to be used with a power system other than that specified in the order,
the power cord must be replaced with one appropriate for the power source used.
Refer to Table 1-1 for a listing of available power cords.
1-6MTX100A MPEG Recorder & Player User Manual
Getting Started
VGA
LAN
Com
Printer
IEEE 1394b
SPI
In/Out
Clock/Ref
In
Trig
In/Out
Applying Power to the
Instrument
After you have verified the operating environment, AC line, and power cord
requirements, plug the power cord into the power connector on the rear panel (see
Figure 1-1), and then plug the power cord into the local power source.
Power connector
Figure 1-1: Rear-panel power connector
NOTE. To make a selection in a Windows dialog box after you power on the
instrument, connect a mouse to the USB connector on the front panel before you
power on.
Power On. Press the ON/STBY switch (see Figure 1-2) to power on the instrument.
After you power on the instrument, verify that the fan on the rear panel is operating.
To verify that the fan is operating, place your hand behind the right side of the
instrument. You should be able to feel the fan's air flow.
CAUTION. Do not operate the instrument if the cooling fan does not operate when
you turn the instrument on. Serious damage to your instrument can occur from
overheating if the cooling fan is not operating.
MTX100A MPEG Recorder & Player User Manual1-7
Getting Started
MTX 100A MPEGRecorder&Player
ON/STBY switch
Figure 1-2: Front-panel ON/STBY switch
The first time you power on the instrument, the Windows Security Alert dialog
box appears as shown in Figure 1-3. This dialog box appears when a program tries
to use the resources or the ports on the system that are covered by the firewall.
Figure 1-3: Windows Security Alert dialog box
Click the Unblock button so that Windows allows the program (MPEG Series
Application) to run.
When you click the Unblock button, the MTX100A application window (Play
screen) is displayed.
1-8MTX100A MPEG Recorder & Player User Manual
Repacking for Shipment
Getting Started
When you ship this instrument, use the original packaging material if possible. If
the original packaging is unfit for use or is not available, repackage the instrument
using the following procedure:
1. Obtain a corrugated cardboard shipping carton having inside dimensions at
least six inches greater than the instrument dimensions and having a carton test
strength of at least 125 kg (275 pounds).
2. If the instrument is being shipped to a Tektronix Service Center for repair or
calibration, attach a tag to the instrument showing the following information:
The owner of the instrument (with address).
The name of a person at your firm who may be contacted if additional
information is needed.
The complete instrum e nt type and serial number.
A description of the service required.
3. Wrap the instrument with polyethylene sheeting or equivalent to protect the
outside finish and prevent entry of packing materials into the instrument.
4. Cushion the instrument on all sides by tightly packing dunnage or urethane
foam between the carton and the instrument, allowing for three inches
(7.62 cm) of padding on each side (including top and bottom).
5. Seal the carton with shipping tape or with an industrial stapler.
6. Mark the address of the Tektronix Service Center and your return address on
the carton in one or more prominent locations.
MTX100A MPEG Recorder & Player User Manual1-9
Getting Started
Functional Check Procedure
Perform the following procedure if you are operating the instrument for the first
time (to verify that the instrument shipped without damage) or you suspect that the
instrument is not working properly:
NOTE. Before you perform this procedure, install the MTX100A using the
instructions listed in Installation starting on page Up Windows XP Professional.
1. Connect the MTX100A to a power source, and then turn the instrument on
using the ON/STBY switch.
2. Press the front-panel MENU button to display the File menu command list.
3. Press the up (
S) or down (T) arrow button to select Open from the list, and
then press the ENTER button to open the Select File dialog box shown in
Figure 1-4.
Figure 1-4: Select File dialog box
4. Press the up (
NOTE. You can select the test40.TRP file in step 4 of this procedure if you need to
decrease the bit rate of the transport str eam due to performance restrictions in your
decoder.
1-10MTX100A MPEG Recorder & Player User Manual
S) or down (T) arrow button to select the test64.TRP file, and
then press the ENTER button. The hierarchy view of the transport stream file
will be displayed on the screen.
Loading...
+ 248 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.