Tektronix MTS4SA,MTS400,MTS430,MTS415 Declassification

xx
MTS400 Series
ZZZ
MPEG Test Systems
Declassication and Security Instructions
www.tektronix.com
P077020800*
*
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges rese rved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O . B ox 5 0 0 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worl d wide , v i sit www.tektronix.com to nd contacts in your area.
Table of Contents
Preface............................................................................................................... 1
Clear and Sanitize Procedures. ... ... ... . ... ... ... . ... ... ... . ... ... ... . ... ... ... . ... ... ... .. .. . ... ... ... . ... ... ... . 3
Data Export Devices.................................. ................................ ......................... 5
Troublesho
How to Clear or Sanitize a Non-Functional Instrument . ... ... . .. . ... ... . .. . ... ... ... . ... ... ... . ... ... ... . 6
How to Recover from Clearing or Removing the Instrument Memory......... ......................... 6
oting..................................................................................................... 6
MTS400 Series Declassication and Security Instructions i
Table of Contents
ii MTS400 Series Declassication and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove memory devices from the MTS400 Series MPEG Test Systems.
These products have data storage (memory) devices and data output devices (USB ports). These instructions tell how to clear or sanitize the memory devices and disable the
data output devices. The instructions also tell how to declassify an
instrument that is not functioning.
Supported Products
The following Tektronix products are covered by this document:
MTS415 Base MPEG Test System
MTS430 Enhanced MPEG Test System
MTS4UP GBE GigE interface upgrade
MTS4UP IPTVD IP Video Gigabit Ethernet Interface with 10/100/1000 Base-T RJ45
electrical port. SFP required for optical interface (options SX, LX, or ZX)
MTS4UP LX 1000BASE-LX wavelength optical port with LC connector upgrade
MTS4UP SX 1000BASE-SX short wavelength optical port with LC connector
upgrade
MTS4UP ZX 1000BASE-ZX long wavelength optical port with LC connector
upgrade
MTS4UP CU 1000BASE-T electrical port with RJ45 connector upgrade
MTS4UP VS 8VSB interface upgrade
MTS4UP QB2 QAM (Annex B) interface upgrade
MTS4UP CF COFDM interface upgrade
MTS4UP EP QPSK/8PSK interface upgrade
MTS4UP BA Buffer Analyzer upgrade
MTS4UP PA PES Analyzer upgrade
Related Documents
The MTS400 Series MPEG Test System Service Manual, Tektronix part number 077-0196-xx, is available on the Tektronix Web site at www.tektronix.com/manuals.
Terms
The following terms may be used in this document:
Clear. This removes data o n media/memory before reusing it in a secured area. All reusable memory is cleared to deny access to previously stored information by standard means of access.
Erase. This is equivalent to clear.
MTS400 Series Declassication and Security Instructions 1
Preface
Media storage/
used to store or export data from the instrument, such as a USB port.
Nonvolatile memory. Data is retained when the instrument is powered off.
Power off. Some instruments have a “Standby” mode, in which power is still
supplied to in Standby mode does not qualify as powering off. F or these products, you will need to either press a rear-panel OFF switch or remove the power source from the instrument.
Remove. This is a physical means to clear the data by removing the memory device fr Manual.
Sanitize. This eradicates the data from media/memory so that the data cannot be recovered by other means or technology. This is typically used when the device will be moved (temporarily or permanently) from a secured area to a non-secured area.
Scrub. This is equivalent to sanitize.
User-modiable. The user can write to the memory device during normal
instrument operation, using the instrument interface or remote control.
data export d evice. This refers to any of se veral devices that can be
the instrument. For the purpose of clearing data, putting the instrument
om the instrument. Instructions are available in the product Service
Volatile memory. Data is lost when the instrument is powered off.
2 MTS400 Series Declassication and Security Instructions
Clear and Sanitize Procedures
Clear and Sani
tize Procedures
Memory Devices
Table 1: Volatile memory devices
Type and User input Function
RDRAM 256 MB
QDR RAM 8MB
DDR RAM 256 MB
SDRAM 128 MB
SRAM 1152 KB
CAM 288 KB IP Trafc buffer
SDRAM 16 MB
SDRAM 64 MB
Microprocessor system memory
Microprocessor system memory
Transport traffic queue
Microprocessor system memory
Microprocessor system memory
Mega FIFO.
modiable?
The following tables list the volatile and nonvolatile memory devices in the standard instrument and listed options. Detailed procedures to clear or sanitize these devic
User
No Written by
No Written by
No Written by
No Written by
No Written by
No Written by
No Written by
No Written by
es, if any, are shown following each table.
Data input method
processor system
processor system
FPGA
processor system
processor system
FPGA
processor system
processor system
Location in instrument To clear To sanitize
Enhanced IP (GigE) board
Enhanced IP (GigE) board
GigE card
GigE card
GigE card
GigE card
RF interface cards (QAM B, 8VSB, PSK, COFDM).
A12 Main card Remove the power
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
source from the instrument for at least 20 seconds.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
MTS400 Series Declassication and Security Instructions 3
Clear and Sanitize Procedures
Table 1: Volatile memory devices, (cont.)
Type and User input Function
DDRAM 1GB
SRAM
Microprocessor system memory
L2 cache No Written by
User
modiable?
No Written by
Table 2: Nonvolatile memory devices
16 M x
ser
instrument rmware processor boot code.
Holds installed option
image
Holds rmware and IGMP subs details
Holds FPGA ima
Hol rmware.
Holds installed options.
image.
IOS
B
,
s.
.
card
cription
ge
ds card
Typ e a nd U input Function
Flash 8 MB Holds
EEPROM
Serial PROM Holds FPGA
Flash 8bits
Flash8Mx 8bits
sh 16 MB
Fla
EEPROM
EEPROM Holds FPGA
Flash
User
modiable?
Yes Firmware
No Factory
No Factory
Yes User i
Yes User input
Yes Fir
No Factory
N
No Factory
Data input method
processor system
processor system
Data inpu method
operations.
ration.
congu
conguration.
nput
mware
operations.
conguration.
o
actory
F conguration.
onguration.
c
Location in instrument To clear To sanitize
SBC
SBC
t
Location instrument To clear To sanitize
Enhanced IP (GigE) board.
Enhanced IP
board.
(GigE)
Enhanced IP (GigE) board.
GigE interface card
GigE interface
d
car
RF Interface cards (QAM-B,
B, PSK,
8VS COFDM).
A12 card
12 card
A
BC
S
Remove the power source from the instrument for at least 20 seconds.
Remove the power source from the instrument for at least 20 seconds.
in
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
/A
N
N/A
N/A
Return the instrument to
ix.
Tektr o n
Return the
ment to
instru Tektronix.
Return the instrument to
onix.
Tektr
nthe
Retur instrument to Tektronix.
Return the instrument to
tronix.
Tek
urn the
Ret instrument to Tektronix.
Return the instrument to
ktronix.
Te
eturn the
R instrument to Tektronix.
Return the
nstrument to
i Tektronix.
4 MTS400 Series Declassication and Security Instructions
Table 2: Nonvolatile memory devices, (cont.)
Clear and Sanitize Procedures
Type and User input Function
Fixed IDE Hard Drive
Fixed SCSI Hard Drive
Holds operating system and application software. Holds user storable data such as test streams, and measurement results.
Holds user storable data such as test streams, and measurement results.
Data Export Devices
User
modiable?
Yes Firmware
Yes Firmware
Data input method
operations, user input.
operations, user input.
Location in instrument To clear To sanitize
Mounted on chassis.
Mounted on chassis.
Erase the hard drive with commercial erasure software. Reinstall Microsoft Windows and the instrument software using the supplied recovery discs.
Erase the hard drive with commercial erasure software. Format hard disk drive.
Remove the hard drive. Store the removed hard driveina secure area or destroy it.
Remove the hard drive. Store the removed hard driveina secure area or destroy it.
The following table lists the data export devices in the standard instrument and listed options:
Table 3: Media storage / data export disable
Type and minimum size Function
LAN Ethernet connector LAN Ethernet connector RF input DVD ±RW
Transfer data N/A N/A SBC N/A Transfer data N/A N/A Enhanced IP (GigE) board. N/A Transfer data N/A N/A RF Interface cards. N/A Store and transport
data.
modiable? Data input method Location in instrument Process to disable
User
Yes User Writeable.
Front of instrument.
Remove all DVDs. Rewriteable DVDs can be formatted, stored in a secure area, or destroyed. Non-rewriteable DVDs can either be stored or destroyed. The DVD drive cannot be disabled.
MTS400 Series Declassication and Security Instructions 5
Troubleshooting
Table 3: Media storage / data export disable, (cont.)
Type and minimum size Function
USB device Store user-storable
data such as transport streams, measurement results, and instrument settings.
Floppy Disk
Store and transport data.
User
modiable? Data input method Location in instrument Process to disable
Yes User Writeable.
Yes User Writeable.
Front of instrument. Remove all USB memory
Front of instrument. Remove all oppy disks.
Troubleshooting
How to Clear or Sanitize a Non-Functional Instrument
If your instrument is not functioning and you need to clear or sanitize it, proceed
lows:
as fol
devices. USB devices can be formatted, stored in a secure area, or destroyed. The USB port cannot be disabled.
Rewriteable oppy can be formatted, stored in a secure area, or destroyed. The oppy drive cannot be disabled.
Enhanced IP (GigE)
Interface Card
terface Cards (QAM
RF In
(Annex B), 8VSB, PSK,
This card uses data stored on the Main Processor card. Clearing the Main Processor card clears all data associated with the Gigabit Ethernet card.
The RF interface cards store immediate values in memory, for example, current frequency. These values are lost when power is removed.
COFDM)
move the hard drive. Store the removed hard drive in a secure area or destroy it.
Hard Drives (IDE and SCSI)
Re
How to Recover from Clearing or Removing the Instrument Memory
Follow the procedures in the MTS400 MPEG Test System Quick Start User Manual to reinstall the operating system and the MTS400 applications.
6 MTS400 Series Declassication and Security Instructions
Loading...