Installation Instructions
These instructions apply to the following MTS 200 Series software products:
HMTS2ES, for MPEG-2 Audio and Video Elementary Stream analysis
HMTS2AN, for MPEG-2 and DVB Transport Stream analysis
HMTS2CR, for MPEG-2 and DVB Transport Stream creation
HMTS2TS, for MPEG-2 and DVB Transport Stream creation and analysis
Installation procedures are the same for all of these products. Likewise, the
installed files, the program group window, the program icons, and the Start/Programs/Tektronix MPEG Test System submenu are identical for all products. The
products differ in the applications that are activated when you enter the General
Password. Refer to Licensed Applications on page 8 for a list of the applications that are included with each product.
System Hardware and Software Requirements
Before attempting to install the software, verify that the target computer meets
the following minimum hardware and software requirements:
Hardware
Software
1
Due to possible hardware and software conflicts, T ektronix cannot guarantee that the software will run on all computers
that meet the minimum requirements. The software has been tested extensively on the following Compaq computers:
Prosignia 500, Proliant 2500, Proliant 1600, and Armada 7700.
HIntel Pentium or Pentium II processor, 120 MHz or greater clock speed
HCD ROM Drive
H32 Mbytes RAM (64 Mbytes recommended)
HAt least 100 Mbytes free internal disk space
HOptional but recommended for MTS2ES: true color (24 bit) graphics
capability
Windows NT Workstation 4.0, service pack 1 or later.
1
MTS 200 Series Version 2.5 Software Installation Instructions
1
Installation Instructions
Parts Lists
Tables 1 and 2 list the items that are shipped with the various MTS200 Series
software products.
T able 1: MTS2ES
QuantityPart numberDescription
1 ea119-5927-00Software protection key (Dongle)
1 ea063-3110-00CD ROM; MPEG Test System software, V ersion 2.5
1 ea071-0370-00Installation Instructions (this document)
1 eaNot saleablePassword Document (063-3158-00)
1 eaNot saleableVinyl envelope for password document (006-8148-00)
1 ea071-0237-00Read This First; MPEG Test System software, V ersion 2.5
1 ea071-0192-00Audio Stream Analyzer User manual
1 ea071-0249-00Video Stream Analyzer User manual
T able 2: MTS2AN, MTS2CR, and MTS2TS
QuantityPart numberDescription
1 ea119-5927-00Software protection key (Dongle)
1 ea063-3110-00CD ROM; MPEG Test System software, V ersion 2.5
1 ea071-0370-00Installation Instructions (this document)
1 eaNot saleablePassword Document (063-3158-00)
1 eaNot saleableVinyl envelope for password document (006-8148-00)
1 ea071-0237-00Read This First; MPEG Test System software, V ersion 2.5
1 ea071-0078-01MPEG Test Systems User manual
2
MTS 200 Series Version 2.5 Software Installation Instructions
Installing the Software
Installation Instructions
Installing the software is a three-step process:
1. Attach the software key to the host computer parallel port.
2. Install the applications on a local disk.
3. Enter the General password to enable your licensed applications.
Step-by-step instructions appear in the following paragraphs.
Attaching the
Software Key
1. If there is a cable attached to the computer parallel port, disconnect the cable.
2. Attach the software key (shown below) to the parallel port and tighten the
retention screws.
3. If you removed a cable in step 1, reconnect it directly to the software key.
The key should not interfere with parallel communications. If you have
difficulty, please contact Tektronix Product Support; refer to ContactingTektronix on page 10 for more information.
NOTE. Licensed MPEG Test System applications will not start or continue
running unless the correct software key is attached to the parallel port. Do not
remove the key or exchange keys with another MPEG Test System user.
Copying the Program Files
MTS 200 Series Version 2.5 Software Installation Instructions
1. Log on to Windows NT as the administrator.
2. Double-click the My Computer icon on your Windows NT desktop and, in
the resulting My Computer window, select the disk icon that represents the
target drive (usually C:). Check the window status bar to verify that the
target disk has at least 100 MB of free space. The MPEG Test System
software will not install on a disk that has less than 100 MB of free space.
3
Installation Instructions
3. Place the MPEG Test System Version 2.5 Installation Software CD ROM
into the CD ROM drive.
4. Select Run... from the Windows NT Start menu. Then enter d:\Setup.exe in
the resulting window (where “d” is the CD ROM drive; use the drive letter
that is correct for your computer) and click OK.
5. In a few seconds, the Tektronix MTS200 Series window appears on the
computer screen.
6. Read the window text and then click Next to proceed to the Choose
Destination Directory window.
7. The default destination folder is C:\Mts200\. Click Next to accept the default
folder.
NOTE. It is strongly recommended that you use the default destination folder.
8. The Setup Type window opens. Select MTS Software Only Products.
9. Click Next. The Select Program Folder window opens. Click Next to
accept the default folder name (Tektronix MPEG Test System) and continue.
The Selection Summary window opens.
4
MTS 200 Series Version 2.5 Software Installation Instructions
Installation Instructions
10. Review the Destination Directory and Start Menu Folder selections; if they
are correct, click Next to proceed with installation.
The setup program begins installing the software. The activity and progress
gauges appear at first to show that installation is progressing.
Installation proceeds without your input (and sometimes with no apparent
activity) for approximately two minutes, depending on your computer
platform.
11. Shortly after empty program group windows appear on your display, an
information dialog box reminds you to verify that the Dongle (software key)
is installed. Be sure that the software key is installed on the parallel port;
then click OK to continue.
12. The Setup Complete window opens; click Finish to continue.
13. A Notepad window opens to display the Readme file. Scan the text for
important information; then select Exit from the Notepad File menu to close
the window.
14. Another Setup Complete window opens. Accept the “Yes, I want to restart
my computer now” option, remove the MPEG Test System disc from the
CD ROM drive, and click Finish to complete setup and reboot the system.
15. When prompted, log on as any user.
MTS 200 Series Version 2.5 Software Installation Instructions
5
Installation Instructions
16. Locate the Tektronix MPEG Test System folder on the Windows NT
desktop and double-click the folder to open the program group window.
The program group window resembles the following illustration.
6
MTS 200 Series Version 2.5 Software Installation Instructions
Installation Instructions
Entering the General
License Password
Perform the remaining steps to enter the general password that corresponds to the
attached software key. Doing so enables the applications that are included with
your MTS 200 Series product.
1. Double-click the License Manager icon to start the application.
The Tektronix Software Protection window appears.
2. Consult the password document supplied with your software and identify the
General password. Enter the three 6-character Hexadecimal numbers of the
password in the corresponding Tektronix Software Protection window
entry fields (lowercase characters are acceptable) and then click OK. A
License message window appears.
3. If the password is correct, click OK to acknowledge the message. If you
made an error entering the password, click OK and return to step 1.
When you enter the correct password, software installation is complete.
MTS 200 Series Version 2.5 Software Installation Instructions
7
Installation Instructions
Licensed Applications
The following applications are included with all Tektronix MTS200 Series
products:
HLicense Manager
HError Injector
HMPEG-2 Help
HUninstall MTS V2.5
Your General Password enables additional applications that correspond to the
MTS 200 Series product as listed in Table 3. You can sample the remaining
applications free of charge for thirty days; refer to Demonstration License on
page 9 for more information.
To delete the icon of an unlicensed application from the Tektronix MPEG Test
System program group, select (highlight) the icon, press
DEL, and click Yes in
the resulting message window.
8
MTS 200 Series Version 2.5 Software Installation Instructions
Demonstration License
Installation Instructions
To remove an unlicensed application from the Start/Programs/Tektronix MPEG
Test System menu, start Windows NT Explorer and open the following path:
C:\Winnt\Profiles\AllUsers\Start Menu\Programs\Tektronix MPEGTest System
Then drag the application shortcut from the right-hand Exploring window pane
to the Windows NT Recycle Bin. Refer to your Windows NT documentation for
more information about changing the appearance or contents of the desktop,
program groups, and the Start menu.
The setup application installs files, icons, and menu items for all MTS applications listed in the previous section, even though some applications are not
standard with your product. You can activate a Demonstration License to enable
all unlicensed applications for thirty days. When you attempt to start an
unlicensed application, the License Management dialog box opens.
Consult the password document supplied with your MPEG Test System product
and identify the Demonstration Password. To activate the Demonstration
License, enter the eight-character hexadecimal password in the LicenseManagement dialog box and then click OK. Once you have correctly entered
the Demonstration Password, all unlicensed or optional applications are available
for the following thirty days.
NOTE. The Demonstration License applies to all unlicensed applications
concurrently and cannot be renewed. Be sure to try all applications of interest
within thirty days of activating the license.
To purchase additional MPEG Test System applications or options, please
contact your Tektronix representative or nearest Tektronix field office.
MTS 200 Series Version 2.5 Software Installation Instructions
9
Installation Instructions
Contacting Tektronix
Product
Support
Service
Support
For other
information
To write usTektronix, Inc.
For application-oriented questions about a Tektronix measurement product, call toll free in North America:
1-800-TEK-WIDE (1-800-835-9433 ext. 2400)
6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail:
tm_app_supp@tek.com
For product support outside of North America, contact your
local Tektronix distributor or sales office. You can also call
1-503-627-2400 between 14:00 and 01:00 UTC (GMT).
Contact your local Tektronix distributor or sales office. Or visit
our web site for a listing of worldwide service locations.
http://www.tek.com
In North America:
1-800-TEK-WIDE (1-800-835-9433)
An operator will direct your call.
P.O. Box 1000
Wilsonville, OR 97070-1000
10
MTS 200 Series Version 2.5 Software Installation Instructions
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.