Tektronix MSO4000, DPO4000 Service Manual

Service Manual
Tektronix 4000 Series Digital Phosphor Oscilloscopes
071-2137--00
This document applies to firmware version 2.00 and above.
Warning
The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
www.tektronix.com
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercede s that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
TekLink is a trademark of Tektronix, Inc.
Tektronix is an authorized licensee of the CompactFlash® trademark.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your area.

Table of Contents

General Safety Summary iii...................................
Service Safety Summary v....................................
Environmental Considerations vii...............................
Preface ix...................................................
Manual Conventions ix..............................................
Related Documentation ix...........................................
Operating Information 1--1.....................................
Theory of Operation 2--1.......................................
Block Diagrams 2--1.................................................
Power Supply 2--2...................................................
I/O Board 2--2......................................................
Main Board 2--2.....................................................
Front--Panel Board 2--3...............................................
Adjustment Procedures 3--1.....................................
Required Equipment 3--1..............................................
Overview of the Adjustment Process 3--2.................................
Factory Adjustment Procedure 3--4......................................
Completing the Procedure 3--8.........................................
Maintenance 4--1..............................................
Preventing ESD 4--1.................................................
Inspection and Cleaning 4--1...........................................
General Care 4--2................................................
Interior Cleaning 4--2.............................................
Exterior Cleaning 4--2............................................
Overview of Removal Procedures 4--6...................................
Removal Procedures 4--8..............................................
Troubleshooting 4--12.................................................
Troubleshooting Procedure 4--13.........................................
Unpacking and Repacking Instructions 4--16...............................
Mechanical Parts List 5--1......................................
Parts Ordering Information 5--1.........................................
Using the Replaceable Parts List 5--2....................................
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
i
Table of Contents

List of Tables

List of Figures

T able 4--1: External inspection check list 4--3......................
T able 4--2: Internal inspection check list 4--4......................
Figure 2--1: Oscilloscope module interconnections 2--1...............
Figure 3--1: Rear panel 3--4.....................................
Figure 3--2: Utility page menu 3--5...............................
Figure 3--3: Calibration selection 3--6.............................
Figure 3--4: Factory information dialog 3--6.......................
Figure 3--5: Digital channel input 3--10............................
Figure 4--1: Locator for trim and cabinet removal 4--7...............
Figure 4--2: Locator for internal mod ules 4--8......................
Figure 4--3: Primary troubleshooting procedure 4--13................
Figure 4--4: AC power supply troubleshooting procedure 4--14.........
Figure 4--5: Module isolation troubleshooting procedure 4--15.........
Figure 5--1: Exploded view, case 5--5..............................
Figure 5--2: Exploded view: DPO4000 front panel and display,
4-channel instruments 5--7...................................
Figure 5--3: Exploded view: MSO4000 front panel and display,
4-channel instruments 5--9...................................
Figure 5--4: Exploded view: DPO4000 front panel and display,
2-channel instruments 5--11...................................
Figure 5--5: Exploded view: MSO4000 front panel and display,
2-channel instruments 5--13...................................
Figure 5--6: Exploded view: DPO4000 Power Supply
and I/O board 5--15.........................................
Figure 5--7: Exploded view: MSO4000 Power Supply
and I/O board 5--17.........................................
Figure 5--8: Exploded view: DPO4000 Main board,
Inverter board, and side fans 5 --19.............................
Figure 5--9: Exploded view: MSO4000 Main board,
Inverter board, and side fans 5 --21.............................
ii
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
ToAvoidFireor
Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use.
Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source.
Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
The inputs are not rated for connection to mains or Category II, III, or IV circuits.
Connect the probe reference lead to earth ground only.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do Not Operate Without Covers. Do not operate this product with covers or panels removed.
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel.
Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
iii
General Safety Summary
Terms in this Manual
Symbols and Terms
on the Product
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
These terms may appear on the product:
H DANGER indicates an injury hazard immediately accessible as you read the
marking.
H WARNING indicates an injury hazard not immediately accessible as you
read the marking.
H CAUTION indicates a hazard to property including the product.
The following symbols may appear on the product:
CAUTION
Refer to Manual
Push button IN
Protective Ground
(Earth) Terminal
Chassis Ground
Mains Connected
ON (Power)
Push button OUT
iv
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
v
Service Safety Summary
vi
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual

Environmental Considerations

This section provides information about the environmental impact of the product.
Product End-of-Life
Handling
Observe the following guidelines when recycling an instrument or component:
Equipment Recycling. Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product’s end of life. In order to avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately.
The symbol shown to the left indicates that this product complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Mercury Notification. This product uses an LCD backlight lamp that contains mercury. Disposal may be regulated due to environmental considerations. Please contact your local authorities or, within the United States, the Electronics Industries Alliance (www.eiae.org) for disposal or recycling information.
Restriction of Hazardous
Substances
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. This product is known to contain lead, cadmium, mercury, and hexavalent chromium.
vii
Environmental Considerations
viii
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual

Preface

Manual Conventions
This service manual provides information that you need to troubleshoot, disassemble, and replace parts on the Tektronix 4000 Series Digital Phosphor Oscilloscopes.
This manual uses certain conventions that you should become familiar with before attempting service.
Modules
Replaceable Parts
Safety
Related Documentation
Throughout this manual, any replaceable component, assembly, or part is referred to by the term module. A module is composed of electrical and mechanical assemblies, circuit boards, interconnecting cables, and user-accessible controls.
This manual refers to any field-replaceable assembly or mechanical part specifically by its name or generically as a replaceable part. In general, a replaceable part is any circuit board or assembly, such as the hard disk drive, or a mechanical part, such as the I/O port connectors, that is listed in the replaceable parts list.
Symbols and terms related to safety appear in the General Safety Summary found at the beginning of this manual.
To read about Use these documents
Installation and Operation Tektronix 4000 Series Digital Phosphor Oscilloscopes User
Manual (available in 11 languages)
Specifications and Performance Tektronix 4000 Series Technical Reference (PDF only)
Programmer Commands Tektronix 4000 Series Programmer Manual (PDF only)
Analysis and Connectivity Tools Getting Started with OpenChoice® Solutions Manual
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
ix
Preface
To read about Use these documents
Installing and testing applica­tions modules
Oscilloscope calibrator Fluke Oscilloscope Calibrator Manual at
Tektronix 4000 Series Application Modules Installation Instructions Manual
http://us.fluke.com
x
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
Operating Information

Operating Information

For information on installing and operating your DPO4000 or your MSO4000 Series Digital Phosphor Oscilloscope, refer to the Tektronix 4000 Series Digital Phosphor Oscilloscopes User Manual.
This manual is available, in 11 languages, on the Web at www.tektronix.com.
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
1- 1
Operating Information
1- 2
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
Theory of Operation

Theory of Operation

This chapter describes the electrical operation of the oscilloscope to the module level. Figure 2--1 shows the oscilloscope module interconnections.

Block Diagrams

AC Line
CompactFlash
Port
USB
J510
Power Supply
XGA
Video
port
J140
J100
I/O Board
J420, J421
J120
J130
Ethernet
port
Trigger
Out
J170
J440 J610
J570 J571
3 Fans
J850
Ch 1
Ch 1
Display
back light
inverter
power
J680
Main board
Attenuator circuit
Ch 2
Ch 2
LCD
Display
J930
Ch 3
J0480
Ch 4
Front Panel
J1
Bezel
buttons
4-channel oscilloscopesAux in
Aux in
2-channel oscilloscopes
Input ports for application modules
Figure 2- 1: Oscilloscope module interconnections
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
2- 1
Theory of Operation

Power Supply

I/O Board

Main Board

The Power Supply board converts AC line voltage to +12 V to power for all internal circuits.
The I/O board contains USB ports, a CompactFlash port, an Ethernet port (LAN), an XGA Video port, and a Trigger Out BNC connector.
The Main board module contains the following functions:
Acquisition System
Trigger System
Display System
The Acquisition system begins with the analog signal path and ends with a digitized signal in memory. The signal enters a channel input, and then passes through an attenuator and preamplifier. The analog signal from each preamplifier goes through a digitizer, a time base controller, and then into acquisition memory. The analog signal from each preamplifier is also distributed to a trigger circuit.
The Trigger system processes the analog signals from the preamplifiers and sends trigger information to the time--base controller. Advanced trigger functions are enabled only when the appropriate application modules and supporting software are installed.
The Display system combines live waveform data from acquisition memory with menus and text, and stores this information in display memory. It then uses this data to refresh the XGA display module (LCD).
2- 2
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
Theory of Operation
Processor System
Power Converter

Front- Panel Board

The Processor system contains a 440EP Power PC microprocessor that controls the entire instrument. The processor system also contains FLASH ROM, system RAM, and interfaces to USB ports and a CompactFlash port.
The Power Converter receives +12 V from the main power supply and generates voltages for the analog and digital circuitry on the Main board.
The Front Panel board contains a microprocessor that reads the front-panel buttons and controls, and then sends this information to the processor system on the Main board. The Front Panel board also generates the probe compensation output signal and provides an interface to the application modules.
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
2- 3
Theory of Operation
2- 4
Tektronix 4000 Series Digital Phosphor Oscilloscopes Service Manual
Adjustment Procedures
Loading...
+ 54 hidden pages