Tektronix Heat Sink Attachment Kits Installation Manual

Page 1
Heat Sink Attachment Kits
020-2616-XX Chipcool 1&2(mobile) 020-2617-XX Desktop 020-2618-XX Cooler Master
Installation Instructions
NOTE. Follow the illustration
steps from the bottom to the top.
020-2616-XX Heat Sink Attachment Kit (Chipcool 1 & 2) for TMSMPH1/2/3
probe head.
071-1629-00
*P071162900*
071162900
Kit Contents
H Attaching hardware kits
Tools Required
H Phillips (P1) screwdriver to tighten the screws
H Flathead screw driver to lock the ZIF socket
H Optional: A torque wrench helps to ensure
reliable connections by meeting the nominal torque values. When attaching screws use 2 in-lbs (0.226 N
Overview
Use this instruction sheet for heat sink hardware installation. See the TMSSY1 and TMSMD1
479-Pin Socket Hardware Support Manual
(071-1605-XX) to connect the probe head to the logic analyzer.
Only qualified personnel should perform these instruction procedures.
CAUTION. To prevent damage to the
probe-head pins, carefully align your pin layout with the probe head pins before installing the probe head.
G
m) of torque.
Insert the four posts into the four heat-sink slots.
Using the supplied screws, attach the two top brackets to the bottom brackets.
Install the microprocessor in the socket and lock the ZIF socket in the probe head.
Connect the probe head to the target system and lock the ZIF socket on the target system.
Using the supplied screws, attach the two bottom brackets to the bottom plate as shown.
Note. Do not use the Spacer kit
(not shown) with a heat sink attachment kit. See the TMSSY1/TMSMD1 Instruction Manual, 071-1605-XX, for more information.
Insert the bottom plate as shown.
6
3
1
Slot
Post
(black)
5
(blue)
4
2
(blue)
Target system
(black)
Procedure
You need to remove your heat sink and retention brackets before installing the probe head.
To install your heat sink hardware, follow the steps in the illustration that apply to your probe head and heat sink hardware.
Page 2
Table 1: 020-2616-XX Replaceable parts list
Description
ACCESSORY KIT; CHIPCOOL 1 & 2 HEATSINK, JEWEL CASE & HEAT SINK PARTS;TMSMPH1/2/3 4 SCREWS 211-3008-XX
2 TOP BRACKETS 407-5035-XX (BLACK)
2 BOTTOM BRACK E TS 407-5037-XX (BLACK)
1 BOTTOM PLATE 386-7440-XX
Table 2: 020-2617-XX Replaceable parts list
ACCESSORY KIT; DESKTOP HEATSINK ATTACH, JEWEL CASE & HEAT SINK PARTS; TMSMPH1, TMSMPH2/3
8 SCREWS,SOCKET CAP 212-0236-XX
4 STANDOFFS 129-1620-XX
Table 3: 020-2618-XX Replaceable parts list
HEATSINK KIT; COOLER MASTER HEATSINK ATTACH, JEWEL CASE & HEAT SINK PARTS; TMSMPH3
2 STAND-OFF POSTS 355-0305-XX
4 SCREWS, PAN HEAD 211-0888-XX
2 UPPER BRACKET 407-5080-XX (GREEN)
2 LOWER BRACKET 407-5078-XX (GREEN)
1 COPPER SPACER 361-1825-XX
Tektronix part number
020-2616-XX
407-5036-XX (BLUE)
407-5038-XX (BLUE)
020-2617-XX
020-2618-XX
407-5081-XX (RED)
407-5079-XX (RED)
Contacting Tektronix
Phone 1-800-833-9200*
020-2617-XX Heat Sink Attachment Kit (Desktop) for
TMSMPH2/3 probe heads.
Place the heat sink inside the brackets.
4
Connect the probe head to the target system and lock the target system ZIF socket.
1
020-2618-XX Heat Sink Attachment Kit (Cooler Master) for TMSMPH3
probe head.
Install the microprocessor in the socket and lock the ZIF socket in
2
the probe head.
3
Using the supplied screws, attach the two brackets to the target system as shown.
Attach the
7
heat sink.
Address Tektronix, Inc.
Web site www.tektronix.com
Sales support
Service support 1-800-833-9200, select option 2*
Technical support www.tektronix.com/support
Department or name (if known) 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
1-800-833-9200, select option 1*
1-800-833-9200, select option 3*
6:00 a.m. -- 5:00 p.m. Pacific Standard Time
* This phone number is toll free in North America.
After office hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices.
For Warranty information, see the Tektronix Website.
Using the two supplied screws, attach the top brackets to the bottom brackets.
Install the microprocessor in the socket and lock the ZIF socket in the probe head.
Connect the probe head to the target system and lock the target system ZIF socket.
Using the two supplied screws, attach the two bottom brackets, then the two standoffs to the bottom plate as shown.
5
4
3
2
Insert the bottom plate as shown.
(Green)
1
(Green)
(Red)
(Red)
Apply thermal
6
grease to both sides of the copper spacer.
Copyright © Tektronix, Inc.
Beaverton, OR 97077