Heat Sink Attachment Kits
020-2616-XX Chipcool 1&2(mobile)
020-2617-XX Desktop
020-2618-XX Cooler Master
Installation Instructions
NOTE. Follow the illustration
steps from the bottom to the top.
020-2616-XX Heat Sink Attachment
Kit (Chipcool 1 & 2) for TMSMPH1/2/3
probe head.
071-1629-00
*P071162900*
071162900
Kit Contents
H Attaching hardware kits
H Instruction sheet
Tools Required
H Phillips (P1) screwdriver to tighten the screws
H Flathead screw driver to lock the ZIF socket
H Optional: A torque wrench helps to ensure
reliable connections by meeting the nominal
torque values. When attaching screws use
2 in-lbs (0.226 N
Overview
Use this instruction sheet for heat sink hardware
installation. See the TMSSY1 and TMSMD1
479-Pin Socket Hardware Support Manual
(071-1605-XX) to connect the probe head to the
logic analyzer.
Only qualified personnel should perform these
instruction procedures.
CAUTION. To prevent damage to the
probe-head pins, carefully align your pin
layout with the probe head pins before
installing the probe head.
G
m) of torque.
Insert the four posts into
the four heat-sink slots.
Using the supplied screws, attach the two
top brackets to the bottom brackets.
Install the microprocessor in the
socket and lock the ZIF socket in
the probe head.
Connect the probe head to
the target system and lock
the ZIF socket on the target
system.
Using the supplied screws, attach the
two bottom brackets to the bottom plate
as shown.
Note. Do not use the Spacer kit
(not shown) with a heat sink
attachment kit. See the
TMSSY1/TMSMD1
Instruction Manual,
071-1605-XX, for more
information.
Insert the bottom
plate as shown.
6
3
1
Slot
Post
(black)
5
(blue)
4
2
(blue)
Target system
(black)
Procedure
You need to remove your heat sink and retention
brackets before installing the probe head.
To install your heat sink hardware, follow the
steps in the illustration that apply to your probe
head and heat sink hardware.

Table 1: 020-2616-XX Replaceable parts list
Description
ACCESSORY KIT; CHIPCOOL
1 & 2 HEATSINK, JEWEL
CASE & HEAT SINK
PARTS;TMSMPH1/2/3
4 SCREWS 211-3008-XX
2 TOP BRACKETS 407-5035-XX (BLACK)
2 BOTTOM BRACK E TS 407-5037-XX (BLACK)
1 BOTTOM PLATE 386-7440-XX
Table 2: 020-2617-XX Replaceable parts list
ACCESSORY KIT; DESKTOP
HEATSINK ATTACH, JEWEL
CASE & HEAT SINK PARTS;
TMSMPH1, TMSMPH2/3
8 SCREWS,SOCKET CAP 212-0236-XX
4 STANDOFFS 129-1620-XX
Table 3: 020-2618-XX Replaceable parts list
HEATSINK KIT; COOLER
MASTER HEATSINK ATTACH,
JEWEL CASE & HEAT SINK
PARTS; TMSMPH3
2 STAND-OFF POSTS 355-0305-XX
4 SCREWS, PAN HEAD 211-0888-XX
2 UPPER BRACKET 407-5080-XX (GREEN)
2 LOWER BRACKET 407-5078-XX (GREEN)
1 COPPER SPACER 361-1825-XX
Tektronix part number
020-2616-XX
407-5036-XX (BLUE)
407-5038-XX (BLUE)
020-2617-XX
020-2618-XX
407-5081-XX (RED)
407-5079-XX (RED)
Contacting Tektronix
Phone 1-800-833-9200*
020-2617-XX Heat Sink
Attachment Kit (Desktop) for
TMSMPH2/3 probe heads.
Place the heat sink
inside the brackets.
4
Connect the probe
head to the target
system and lock the
target system ZIF
socket.
1
020-2618-XX Heat Sink Attachment
Kit (Cooler Master) for TMSMPH3
probe head.
Install the microprocessor in the
socket and lock the ZIF socket in
2
the probe head.
3
Using the supplied
screws, attach the two
brackets to the target
system as shown.
Attach the
7
heat sink.
Address Tektronix, Inc.
Web site www.tektronix.com
Sales
support
Service support 1-800-833-9200, select option 2*
Technical support www.tektronix.com/support
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
1-800-833-9200, select option 1*
1-800-833-9200, select option 3*
6:00 a.m. -- 5:00 p.m. Pacific
Standard Time
* This phone number is toll free in North America.
After office hours, please leave a voice mail
message.
Outside North America, contact a Tektronix sales
office or distributor; see the Tektronix web site
for a list of offices.
For Warranty information, see the Tektronix Website.
Using the two supplied screws,
attach the top brackets to the
bottom brackets.
Install the microprocessor in
the socket and lock the ZIF
socket in the probe head.
Connect the probe head to
the target system and lock
the target system ZIF
socket.
Using the two supplied
screws, attach the two
bottom brackets, then the
two standoffs to the bottom
plate as shown.
5
4
3
2
Insert the bottom
plate as shown.
(Green)
1
(Green)
(Red)
(Red)
Apply thermal
6
grease to both
sides of the
copper spacer.
Copyright © Tektronix, Inc.
Beaverton, OR 97077