Tektronix H600 RFHawk,SA2600 User manual

xx
H600 RFHawk and
ZZZ
SA2600 Spectrum Analyzer
Declassication and Security Instructions
www.tektronix.com
077-2301-00
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges rese rved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
NetTek is a registered trademark of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O . Bo x 5 00 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. Worl d wide , visi t www.tektronix.com to nd contacts in your area.
Table of Contents
Preface .............................................................................................................. iii
Clear and Sanitize Procedures. ... ... ... . ... ... ... . ... ... ... . . .. . ... ... ... . ... ... ... . ... ... ... .. .. . ... ... ... . ... ... 1
Memory Devices............................................................................................... 1
Data Export
Troubleshooting..................................................................................................... 3
How to Clear or Sanitize a Non-Functional Instrument .. ... . .. . ... ... ... . ... ... ... .. .. . ... ... ... . ... ... .. 3
Devices........................................................................................... 2
H600, SA2600 Declassication and Security Instructions i
Table of Contents
ii H600, SA2600 Declassication and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove memory devices from the H600 RFHawk or the SA2600 Spectrum Analyzer instrument.
This product has data storage (memory) devices and data output devices (USB ports). The
Clear or sanitize the memory devices
Clear or sanitize an instrument that is not functioning
se instructions tell how to do the following:
Products
Terms
The following Tektronix product is covered by this document:
H600 RFHawk
SA2600 S
The following terms may be used in this document:
Clear. This removes data on media/memory before reusing it in a secured area. All reusable memory is cleared to deny access to previously stored information by standard means of access.
Erase. This is equivalent to clear.
Media storage/data export. Various devices that are used to store or export data
from the instrument, such as a USB port.
Nonvolatile memory. Data is retained when the instrument is powered off.
Remove. Thisisaphysicalmeanstoclearthedatabyremovingthememory
device from the instrument. Instructions are available in the product service manual.
Sanitize. This eradicates the data from media/memory so that the data cannot be recovered by other means or technology. This is typically used when the device will be moved (temporarily or permanently) from a secured area to a non-secured area.
pectrum Analyzer
Scrub. This is equivalent to sanitize.
User-modiable. The m emory device can be written to by the user during normal
instrument operation, using the instrument’s user interface or remote control.
Volatile memory. Data is lost when the instrument is powered off.
H600, SA2600 Declassication and Security Instructions iii
Preface
iv H600, SA2600 Declassication and Security Instructions
Clear and Sanitize Procedures
Memory Device
Table 1: Vol
atile Memory Devices
s
Type and minimum size Function
SDRAM (2) 16M x 16
SRAM (3) 256K x 16
SRAM, 2M x 18
Tabl e 2
Type an
: Nonvolatile Memory D evices
d
System memory
DSP program and data memory
Acquisition me mory No
minimum size Function
M_System DiskOnChip 32M x 8 or Sandisk 512M x 8
Flash (2) 16M x 8
EEPROM 128 x 8
EEPROM 128 x 8
Flash 8M x 16
File system Yes User writeable,
Operating system and register settings
Ethernet No Factory
Storing internal calibration data
FPGA conguration, DSP acquisition and measurement control
The following tables list the volatile and nonvolatile memory devices in the standard instrument and listed options.
User modiable
Yes Written
No
User modiable Input method Location Process to clear
Yes User input
No Written during
No Factory
Input method Location Process to clear
by system processor
Read/write by DSP processor
Read/write by DSP processor
default location for application software, application settings and measurement result les (My Device\BuiltInDisk folder)
programmed
factory or service calibration
programmed, software updates, and used by application
Platform processor board Remove power from the
Module digital signal processor board Power down the module
Module digital signal processor board Power down the module
Mainframe processor board
Mainframe processor board
Mainframe processor board
Module RF board
Module digital signal processor board
System reset (See page 2, Perform a System Reset.)
System reset (See page 2, Perform a System Reset.)
Store the instrument in a secure area
Store the instrument in a secure area
Store the instrument in a secure area, or destroy the instrument
instrument for at least 20 seconds
by exiting the H600 or SA2600 application
by exiting the H600 or SA2600 application
H600, SA2600 Declassication and Security Instructions 1
Clear and Sanitize Procedures
Perform a System Reset
Data Export Devices
Table 3: Data Export Devices
Type Function
USB host port (supports removable USB ash drive)
USB slave port
PCMCIA Support of PCMCIA-compliant
LAN Ethernet connector
User storage of measurement data, screen images, and instrument setups; remote control anddatatransfertoaPC
Remote control and data transfer to a PC
devices including ATA ash memory cards
Remote control and data transfer to a PC
This procedure
does not erase or change factory calibration constants. Resetting
the system puts the instrument back to factory specications.
1. Power on the in
strument.
2. Tap the Start button.
3. Select Programs > Tektronix Utilities > System Reset.
NOTE. After a system reset, the user settings and data are cleared, but the
instrumen
t operating software is preserved.
The following table lists the data export devices in the standard instrument and listed options.
User modiable
Yes
Yes
Yes User writable
Yes Remote
Input method Location Process to disable
Software operations, remote control and data transfer
Software operations, remote control and data transfer
control and data transfer
USB host port on top of instrument
USB device port on top of instrument
Right side of instrument
Ethernet port on top of instrument
The USB ash drive can be removed and destroyed.
The USB host port cannot be disabled.
The USB device port cannot be disabled.
Remove all devices attached to the port. Remove all memory devices and format them, store them in a secure area, or destroy them. The PCMCIA device port cannot be disabled.
The Ethernet port cannot be disabled.
2 H600, SA2600 Declassication and Security Instructions
Troubleshooting
How to Clear or Sanitize a Non-Functional Instrument
If your instrument is not functioning and you need to clear or sanitize it, proceed as follows:
H600, SA2600
USB Flash Drive
Charges
There are no customer-removable internal memory devices or boards in the H600 or SA2600. Refer to your company’s internal policies regarding handling or disposal of the module.
Remove the USB flash drive, and then refer to your company’s internal policies regarding handling or disposal of the ash drive.
Replace the time of replacement.
ment of any missing hardware will be charged according to the rate at
H600, SA2600 Declassication and Security Instructions 3