Up to 40 GS/s Real-time Sample Rate on One Channel, up to 20 GS/s
on Two Channels, and up to 10 GS/s on Three or Four Channels
Up to 500 Megapoint Record L ength with MultiView Zoom™
>250,000 wfms/s Maximum Waveform Capture Rate with FastAcq™
FastFrame™ Segmented Memory Acquisition Mode with
>310,000 Waveforms per Second Cap ture Rate
electable Bandwidth Limit Filters for Better Low-f reque ncy
User-s
Measurement Accuracy
Ease-of-Use Features
Pinpoint®Triggering provides the Most Flexible and Highest
Performance Triggering, with over 1400 Combinations to Address
lly Any Triggering Situation
Virtua
Visual Trigger Precisely Qualifies Triggers and Finds Unique Events in
Complex Waveforms
Advanced Search and Mark to Find SpecificEventsintheEntire
Waveform
Optional Serial Triggering and Analysis
Optional Technology Specific Analysis
MyScope®Custom Control Windows and Right Mouse Click Menus for
Exceptional Efficiency
53 Automated Measurements, Waveform Histograms, and FFT Analysis
for Simplified Waveform Analysis
TekV P I®Probe Interface supports Active, Differential, and Current
Probes for Automatic Scaling and Un its
12.1 in. (307 mm) Bright XGA Display with Touch Screen
USB Host Ports on the Front and Side Panels for Quick and Easy Data
Storage, Printing, and Connecting USB Peripherals
Integrated 10/100/1000BASE-T Eth ernet Port for Network Connection
and Video Out Port to Export the Oscilloscope Display to a Monitor or
Projector
Microsoft®Windows 7 64-bit Operating System for Easy Connectivity
and Integration into Your Environment
LXI Class C Compliant
Automated Serial Triggering and Decode Options for I2C, SPI,
RS-232/422/485/UART, and USB 2.0
Automated Serial Analysis for MIPI®D-PHY DSI-1 and CSI -2
Automated Serial Decode and Vehicle Network Monitoring of CAN and
LIN
Clock Recovery from S erial Data Streams
64-bit NRZ Serial Pattern Trigger for Isolation of Pattern-dependent
Effectsupto1.25Gb/s
Software Solutions provide Built-in Domain Expertise for MIPI
D-PHY, Ethernet, and USB 2.0 Compliance Testing, Jitter, Timing, Eye
Diagrams, Power, DDR Memory Bus Analysis, and Wideband RF
Limit and Mask Testing provide Quick Insight into Signal Characteristics
®
Data Sheet
Simplified Analysis for Complex Digital
Designs
With the DPO7000C Digital Phosphor Oscilloscope Series, you can analyze
analog and serial bus signals with a single instrument to quickly find and
diagnose problems in complex designs. Bandwidths up to 3.5 GHz and
sample rates u
see fast-changing signal details. To capture long windows of signal activity
while maintaining fine timing resolution, the DPO7000C Se ries o ffers a dee p
record length of up to 12.5M points standard on all channels and an optional
record length of up to 500M points on one channel.
With Advanced Search and Mark and MultiView Zoom™ features for rapid
waveform navigation, and more than 15 optional software and analysis
packages for common technologies and in-depth analysis tasks, the
DPO7000C Ser
to simplify and speed debug of your complex design.
p to 40 GS/s ensure you have the performance you need to
ies from Tektronix provides the feature-rich tools you need
Comprehensive Features Speed Every Stage
of Debug
The DPO7000C Series offers a robust set of features to speed every stage
of debugging your design – from quickly discovering an anomaly and
capturing it, to searching your waveform record for the event and analyzing
its characteristics and your device's behavior.
Discover
To debug a design problem, first you must know it exists. Every
design engineer spends time looking for problems in their design, a
time-consuming and frustrating task without the right debug tools.
Discover –
of capturi
The DPO7000C Series offers the industry's most complete visualization
of signals, providing fast insight into the real operation of your device.
Tektronix proprietary FastAcq™ technology delivers a fast waveform
capture – greater than 250,000 waveforms per second – th at enables you to
see glit
true nature of device faults. A digital phosphor display with color intensity
grading shows the history of a signal's activity by using color to identify
areas of the signal that occur more frequently, providing a visual display
of just how often anomalies occur.
Fast waveform capture rate - over 250,000 wfm/s - maximizes the probability
ng elusive glitches and other infrequent events.
ches and other infrequent transients within s econds, revealing the
2 www.tektronix.com
Digital Phosphor Oscilloscopes — DPO7000C Series
Capture–T
complete s
quickly ca
riggering on a specific transmit data packet going across an RS-232 bus. A
et of triggers, including triggers for specific serial packet content, ensures you
pture your event of interest.
Capture
Discovering a device fault is only the first step. Next, you must capture the
event of interest to identify root cause.
The DPO7000C Series provides a complete set of triggers – inc luding runt,
glitch, width, timeout, transition, pattern, state, setup/hold violation, window,
comm, and serial pattern – to help quickly find your event. Enhanced
Triggering reduces trigger jitter at the trigger point. In this mode, the trigger
point can be used as a measurement reference.
To enable complex system debug and validation, the DPO7000C Series
®
provides Pinpoint
de trigger performance up to the bandwidth of th e oscilloscope and
to provi
triggering, using Silicon Germanium (SiGe) technology
over 1400 trigger combinations. Most other trigger systems offer multiple
trigger types only on a single event (A event), with the delayed trigger (B
event) selection limited to edge-type triggering, and often do not provide a
way to reset the trigger sequence if the B event doesn’t occur. But Pinpoint
triggering provides a full suite of advanced trigger types on both A and B
s with Reset triggering to begin the trigger sequence again after a
trigger
specified time, state, or transition so that even events in the most complex
signals can be captured.
Finding the right characteristic of a complex signal can require hours of
collecting and sorting through thousands of acquisitions for the event of
interest. Defining a trigger that isolates the desired event and shows data
only when the event occurs speeds up this process. The optional Visual
Trigger makes the identification of the desired waveform events quick and
scanning through all waveform acquisitions and comparing them to
easy by
on-screen areas (geometric shapes).
to a 500M point record length, you can capture many events of
With up
interest, even thousands of serial packets, in a single acquisition for further
Search – Results of an advanced search for a runt pulse or a narrow glitch within a long
waveform record. Each instance of the runt or glitch is automatically marked for easy
reference.
analysis while maintaining high resolution to zoom in on fine signal details.
Investigate multiple segments of your waveform capture simultaneously
with MultiView Zoom™ to quickly compare events in real time. FastFrame™
Segmented Memory mode enab les you to make efficient use of large
records by capturing many trigger events in a single record eliminating large
time gaps between events of interest. View and measure the segments
individually or as an overlay.
From triggering on specific packet content to automatic de co de in multiple
data formats, the DPO7000C Series pro vid es integrated support for a
broad range of serial buses – I
2
C, SPI, RS-232/422/485/UART, USB 2.0,
CAN, LIN, and MIPI D-PHY. The ability to decode up to 16 serial buses
simultaneously means you gain insight into system-level problems quickly.
Search
Finding your event of interest in a long waveform record c an be time
consuming without the right search tools. With today's record lengths
pushing beyond a million data points, locating your event can mean scrolling
through thousands of screens of signal activity.
The DPO7000C Series offers the industry's most comprehensive search
and waveform navigation with the standard Advanced S earch and Mark
and front-panel controls. User marks allow you to mark any
feature
location that you m ay want to reference later for further investigation. Or,
automatically search your entire record for the criteria yo u define. Along the
way it will aut omatically mark every occurren ce of your defined event so
you can quickly move between events. The advanced search and mark
capability of th e DPO7000C Series can search for up to eight different
imultaneously and stop a live acquisition when it finds an event
events s
of interest, saving even more time.
www.tektronix.com 3
Data Sheet
Analyze – Waveform histogram of a falling edge showing the distribution of edge position
(jitter) over time. Included are numeric measurements made on the waveform histogram
data. A comprehensive set of integrated analysis tools speeds verification of your design's
performance.
Analyze
Verifying that your prototype's performance matches simulations and meets
the project's design goals requires a nalyzing its behavior. Tasks can
range from simple checks of rise times and pulse widths to sophisticated
power loss analysis, characterization o f system clocks, and investigation
of noise sources. The DPO7000C Series offers a comprehensive set of
integrated analysis tools including waveform- and screen-based cursors, 53
automated measurements, a dvanced waveform math including arbitrary
equation editing, waveform histograms, and FFT a nalysis.
Every DPO7000C Series oscilloscope includes the DPOJET Essentials jitter
and eye pattern analysis software package, extending the oscilloscope's
measurement capabilities to make measurements over contiguous clock
and data cycles in a single-shot real-time acquisition. This enables
measurement of key jitter and timing analysis parameters s uch as Time
Interval Error and Phase Noise to help characterize possible system timing
issues. Analysis tools such as plots for time trends and histograms quickly
show how timing parameters change over time, and spectrum analysis
quickly shows the precise frequency and amplitude of jitter and modulation
sources.
Specialized application support fo r serial bus debug and compliance test,
jitter and eye pattern analysis, power sup ply design, limit and mask testing,
DDR memory bus analysis, and wideband RF is also available.
Advanced Search and Mark
A 12.5M point standard record length represents thousands of screens
of information. The DPO7000C Series enables you to find your event in
seconds with Advanced Search and Mark.
Search ste
Search step 2: Advanced Search and Mark automatically searches through the record and
marks each event with a solid colored triangle. You can then use the Previous and Next
buttons to jump from one event to the next.
User M
p 1: You define what you would like to find.
arks
Press the Set/Clear front-panel button to place one or more marks on
the wa
Previous (←)andNext (→) buttons on the front panel.
Search Marks
earch button allows you to automatically search through your long
The S
acquisition looking for user-defined events. All occurrences of the event
are highlighted with search marks and are easily navigated to, using the
front-panel Previous (←) and Next (→) buttons. Search types include
edge, glitch, width, timeout, runt, pattern, state, setup and hold, transition,
and window.
4 www.tektronix.com
Digital Phosphor Oscilloscopes — DPO7000C Series
osphor technology enables greater than 250,000 wfm/s waveform capture rate
Digital ph
ime color grading on the DPO7000C Series.
and real-t
Digital Phosphor Technology
The DPO7000C Series' digital ph osphor technology provides you with fast
insight into the real operation of your device. Its fast waveform capture
rate – greater than 250,000 wfm/s – gives you a high probability of quickly
seeing the infrequent problems common in digital systems: runt pulses,
glitches, timing issues, and more.
Waveforms are superimposed with one another and waveform points are
color coded by frequency of occurrence. This quickly highlights the events
ur more often over time or, in the case of infrequent anomalies,
that occ
occur less often.
With the
DPO7000C Series, you can choose infinite p ersistence or variable
persistence, determining how long the previous waveform acquisitions stay
on-screen. This allows you to determine how often an anomaly is occurring.
Visual Trigger (Optional)
The Visual Trigger option adds an additional dimension to the standard
trigger system that provides a n intuitive method of triggering based on
shapes in the oscilloscope’s graticule. It enables the user to define shapes
scilloscope’s display that qualify trigger events for the incom ing
on the o
signals. Areas can be created using a variety of shapes including triangles,
rectangles, hexagons, or trapezoids to fit the area to the particular trigger
behavior desired. Once shapes are created on the oscilloscope’s display,
they can be positioned and/or re-sized dynamically while the oscilloscope
is in Run mode to create ideal trigger conditions. Visual Trigger can be
ed with the standard triggers and act as a Boolean logic qualifier
combin
for the “A” and “B” events.
Serial Triggering and Analysis (Optional)
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difficult. The
DPO7000C Series offers a robust set of tools for debugging serial buses
Eye Diagram triggering using optional Visual Trigger.
Triggering on a specific OUT Token packet on a USB full-speed serial bus. A bus
waveform provides decoded packet content including Start, Sync, PID, Address, End
Point, CRC, Data values, and Stop.
with automat
ic trigger and decode on I
2
C, SPI, RS-232/422/485/UART,
CAN, LIN, and USB 2.0, and decode for MIPI D-PHY DSI-1 and CSI-2
serial buses.
Serial Triggering
Trigger on packet content such as start of packet, specificaddresses,
specific data content, unique identifiers, etc. on popular serial interfaces
such as I
2
C, SPI, RS-232/422/485/UART, CAN, and USB 2.0.
Bus Display
Provides a higher-level, combined view of the individual signals (clock, data,
chip enable, etc.) that make up your bus, making it easy to identify where
packets begin and end and identifying subpa cket components such as
address, data, identifier, CRC, etc.
www.tektronix.com 5
Data Sheet
e showing decoded serial packet data in a long acquisition.
Event tabl
Bus Decoding
Tired of having to visually inspect the waveform to count clocks, determine if
each bit is a 1 or a 0, combine bits into bytes, and determine the hex value?
Let the oscilloscope do it for you! Once you've set up a bus, the DPO7000C
Series will decode each packet on the bus, and display the value in hex,
binary, decimal (USB only) or ASCII (USB and RS-232/422/485/UART only)
in the bus
Event Tab
In addition to seeing decoded packet data on th e bus waveform itself, you
can view a
a software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.).
Bus Searching
Serial triggering is very useful for isolating the event of interest, but once
you’ve captured it and need to a nalyze the surrounding data, what do
waveform.
le Display
ll captured packets in a tabular view much like you would see in
CAN and LIN Timing and Protocol Decode.
you do? In the past, users had to manually scroll through the waveform
counting and converting bits and looking for what caused the event. With
the DPO7000C Series, you can have the oscilloscope automatically search
through the acquired data for user-defined criteria including serial packet
content. Each occurrence is highlighted by a search mark. Rapid navigation
between marks is as simple as pressing the Previous (←)andNext (→)
buttons on the front panel.
CAN and LIN Timing and Protocol Decode
Software (Optional)
The optional CAN/LIN serial analysis software package (Option LSA)
enables you to ensure seamless and reliable operation of a CAN or LIN
. The software measures oscillator tolerance and pro pagation delay
network
on CAN buses, provides CAN triggering, and simultaneously decodes CAN
and LIN messages.
6 www.tektronix.com
Digital Phosphor Oscilloscopes — DPO7000C Series
USB 2.0 Com
pliance Testing.
Serial Bus Compliance Test (Optional)
Software packages for automated com pliance test are available for
MIPI D-PHY (Option D-PHY), Ethernet 10BASE-T, 100BASE-TX, and
1000BASE-T (Option ET3), and USB 2.0 (Option USB) physical-layer
devices. These software packages enable you to conduct testing using the
standard's specified compliance tests.
Power Analysis (Optional)
The optional power analysis software package (Option PWR) e nables
quick and accurate analysis of power quality, switching loss, harmonics,
magnetic measurements, safe operating area (SOA), modulation, ripple,
and slew rate (di/dt, dv/dt). Automated, repeatable power measurements
able with a touch of a button; no external PC or complex software
are avail
setup is required. The package includes a report generation tool to create
customizable, detailed reports to document your measurement re sults.
Advance
Diagram
The optional DPOJET Advanced software package (Option DJA) offers
extende
insight into jitter and timing as well as other signal quality issues. DPOJET
Advanced adds advanced tools such as Rj/Dj separation, eye diagram
masks, and Pass/Fail limits for conformance testing. The innovative
d Analysis, Jitter, Timing, and Eye
Measurements (Optional)
d capabilities, providing a complete suite of analysis tools for
Switching Loss measurements. Automated power measurements enable quick and
accurate analysis of common power parameters.
Advanced Analysis, Jitter, Eye Diagram, and Timing measurements.
one-touc
Advanced is also a measurement frame work that works in conjunction with
standards-specific compliance test packages for a pplications such as DDR
memory and USB.
h wizard makes setup for jitter measurements easy. DPOJET
www.tektronix.com 7
Data Sheet
ng an OC-12 signal, capturing any violations of the mask.
Mask testi
Limit and Mask Testing (Optional)
The optional limit test (Option LT) and mask te st (Option MTM) software
packages are useful for long-term signal monitoring, characterizing signals
during design, and testing on a pro duction line. The limit test software
compares a tested signal to a known good or "golden" version of the
same signal with user-defined vertical and horizontal tolerances. The
mask test softw
and computer standards for easily checking compliance to a standard.
Additionally, custom masks can be created and used for characterizing
signals. With both software packages you can tailor a test to your specific
requirements by defining test duration in a number of wavefo rms, setting
a violation threshold that must be met before considering a test a failure,
counting hits
violations, test failure, a nd test complete. Whether specifying a limit
template or a mask, conducting pass/fail tests in search of waveform
anomalies such as glitches has never been e asier.
are includes a robust set of masks for telecommunications
along with statistical information, and setting actions upon
DDR M emory Bus Analysis (Optional)
The optional DDR memory analysis software package (Option DDRA)
automatically identifies DDR1, DDR2, DDR3, LP-DDR, LP-DDR2, and
GDDR3 Reads a
with Pass/Fail results on all edges in e ve ry Read and Write burst, perfect
for debugging and troubleshooting DDR memory buses. Also provided are
common measurements of clock, address, and control signals. Used in
conjunction with DPOJET (Option DJA), Option DDRA is the fastest way to
debug complex memory signaling issues.
nd Writes and makes JEDEC conformance measurements