CSA8UP, TDS8UP, CSA8BUP, TDS8BUP,
CSA82UP, TDS82UP, & DSA82UP
Upgrades for TDS8000 Series, CSA8000 Series, and
DSA8200 Instruments
071-1385-03
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered tradem arks of Tektronix, Inc.
Windows is a registered trademark of Microsoft Corporation in the United Stat es and other countries.
Contacting Tektronix
Tektronix, Inc.
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
HIn North America, call 1-800-833-9200.
HWorldwide, visit www.tektronix.com to find contacts in your area.
Kit Description
Kit Parts List
This kit provides upgrades for the CSA8000, TDS8000, CSA8000B,
TDS8000B, CSA8200, TDS8200, and DSA8200 instruments. Included with the
kit is the latest version of the instrument product software applicable to your
product.
This kit also includes one or more of the following upgrade options:
HOption JNB
HOption XP
HOption MU1
HOption CPU
Tektronix installation service (Option IF) is also available for any of the
upgrades. If installation service is desired, please contact the service center in
your region to schedule installation.
QuantityPart numberDescription
1071-1385-03MANUAL KIT INSTRUCTIONS
1 of the following:
Product Software Upgrade
This kit provides the latest version of product software. Depending on the
product upgrade kit purchased, the kit either has the latest DSA8200 Product
Software CD-ROM or the 8000 Series Product Software CD-ROM (for the CSA
and TDS8000 Series instruments).
This kit provides instructions (beginning on page 5) to upgrade to the latest
version of product software.
020-2526-xx8000 SERIES PRODUCT SOFTWARE KIT
(for use with the
TDS8000B, CSA8200, TDS8200
Microsoft Windows 2000)
This product software (020--2526--xx) cannot be installed on an
instrument running Microsoft Windows XP. If you are upgrading
to Windows XP, use Option XP which provides both the
Windows XP operating system and the product software
designed for Windows XP.
This kit includes at least one of the following upgrade options.
Option JNB
Option XP
Option JNB provides a software key code only. The JNB software is available on
the product software CD-ROM. Instructions to install the JNB software
application and how to use the software key is available in the installation
instructions provided with the product software CD-ROM kit.
This option can be installed on the following products:
HCSA8000 or TDS8000 Series instruments running the Microsoft Windows
2000 or XP operating system and has 512 MB of memory
HDSA8200 instruments
Option XP provides the Microsoft Windows XP Operating System designed
specifically for the CSA8000 and TDS8000 series instruments. Option XP
includes a new hard disk drive with both the operating system and the product
software pre-installed. This option is for the CSA8000, TDS8000, CSA8000B,
TDS8000B, CSA8200, and TDS8200 instruments currently running the
Windows 2000 operating system. An installation document (071--2156--xx) is
provided with Option XP.
NOTE. Option XP requires the use of product software specifically designed for
use with Microsoft Windows XP operating system. The Option XP kit provides
both a hard disk drive with the correct product software pre-installed along with
back-up copies of the Windows XP operating system and the 8000 series product
software on CD-ROMs.
Option MU1
Option CPU
2
Option MU1 contains 256 MB of RAM to upgrade your instrument to a total of
512 MB of RAM. This option is for the CSA8000, TDS8000, CSA8000B, and
TDS8000B instruments that have less than 512 MB of factory installed RAM.
Option MU1 cannot be installed in instruments that have used both memory slots
on the CPU board in the instrument. Instruments with 512 MB of factoryinstalled RAM have used both memory slots. You can verify the instrument
memory by selecting My Computer > Properties. Click the General tab and
verify the displayed amount of RAM.
Option MU1 is not required to install the product software provided in this kit.
An installation document (071--1784--xx) is provided with Option MU1.
Option CPU provides a new CPU board capable of running the Microsoft
Windows 2000 or Windows XP operating system. This option is for the
CSA8000 and TDS8000 instruments. An installation document (071--1384--xx)
is provided with Option CPU.
NOTE. Option CPU currently has 512 MB of memory installed on the CPU
board as part of the Option CPU kit, using all available memory slots. Option
MU1 cannot be used if all memory slots are filled on the CPU board.
Earlier shipments of Option CPU contained 256 MB of memory, using only one
of the two available memory slots. On these CPU boards, Option MU1 can be
used to bring the installed memory up to 512 MB of memory.
You can verify the instrument memory by selecting My Computer > Properties.
Click the General tab and verify the amount of RAM.
To install your new product software (CD-ROM 063--3704--xx), you may have to
install other upgrade options. See the installation instructions and requirements
for the instrument in which you are preparing to install the product software.
STOP. If you ordered this kit with kit Option MU1, you can upgrade to Option
MU1 with or without installing the product software provided in this kit. If
installing the product software, install it first as instructed in the procedures that
follow, and afterwards follow the instructions in kit Option MU1 to install
Option MU1.
Minimum Equipment List
Required equipmentPart number
USB or PS-2 KeyboardSupplied with instrument
CSA8000 and TDS8000 Series
To use this product software (CD-ROM 063--3704--xx), the instrument must be
running the Microsoft Windows 2000 Operating System. The table below shows
the instruments and the required options needed before installing the product
software.
ProductSerial numberRequirements
CSA8000All serial numbersRequires kit options CPU and W2K
TDS8000All serial numbersRequires kit options CPU and W2K
The following steps are required to upgrade the CSA8000 and TDS8000 (non-B
version) instruments to product software version 2.x.
STOP. You should not install kit Option MU1 if installing kit Option CPU.
Current versions of kit Option CPU already provide the additional memory that
Option MU1 adds.
Use the kit option CPU to the TDS8UP or CSA8UP kit. The CPU option kit
upgrades the CPU board to a Microsoft Windows 2000 compatible CPU
board. The CPU option kit provides all the necessary parts and installation
instructions.
2. Install option W2K.
Use the kit option W2K to the TDS8UP or CSA8UP kit. The W2K option
kit upgrades the operating system to Microsoft Windows 2000. The W2K
option kit provides the Microsoft Windows 2000 OS Restore CD-ROMs and
installation instructions.
After installation, attach the Microsoft Windows 2000 Certificate of
Authenticity label onto the rear of the instrument.
3. Install the product software upgrade.
Use the the product software provided in this kit to install product software.
Use the installation instructions provided with the 8000 Series InstrumentsProduct Software.
CSA8000B and TDS8000B Series (SN B029999 and Below)
To use this product software, the instrument must be running the Microsoft
Windows 2000 Operating System. The table below shows the instruments and
the required options needed before installing the Product Software.
ProductSerial numberRequirements
CSA8000BB029999 and belowRequires kit option W2K
TDS8000BB029999 and belowRequires kit option W2K
These steps are required to upgrade the CSA8000B and TDS8000B instruments
to product software version 2.x.
1. Install option W2K.
Use the kit option W2K to the TDS8BUP or CSA8BUP kit. The W2K
option kit upgrades the operating system to Microsoft Windows 2000. The
W2K option kit provides the Windows 2000 OS Restore CD-ROMs and
installation instructions.
After installation, attach the Microsoft Windows 2000 Certificate of
Authenticity label onto the rear of the instrument.
Use the the product software provided in this kit to install product software.
Use the installation instructions provided with the 8000 Series InstrumentsProduct Software.
CSA8000B and TDS8000B Series (SN B030000 and Above),
CSA8200 and TDS8200 Series
Install the product software upgrade. No additional upgrades are required for
these instruments.
Use the the product software provided in this kit to install product software. Use
the installation instructions provided with the 8000 Series Instruments ProductSoftware.
DSA8200
Installation Instructions
Install the product software upgrade. No additional upgrades are required for
these instruments.
Use the the product software provided in this kit to install the product software.
Use the installation instructions provided with the DSA8200 Instrument ProductSoftware CD-ROM kit.