Tektronix TDS8200, CSA8200 User Manual

CSA8200 Communications SignalAnalyzer TDS8200 Digital Sampling Oscilloscope Quick Start User Manual
*P071148202*
071-1482-02
CSA8200 Communications SignalAnalyzer TDS8200 Digital Sampling Oscilloscop e Quick Start User Manual
www.tektronix.com
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change pri vileges reserved.
TEKTRONIX, TEK, TEKPROBE, and FrameScan are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Dri ve P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your area.
Warranty 2
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or ina dequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) t o repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficul ty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

General Safety Summary iii.....................................................................
Preface v..................................................................................
Documentation v.........................................................................
Conventions Used in this Manual vi............................................................
Key Features 1..............................................................................
Install Your Instrument 3.......................................................................
Standard Accessories 3....................................................................
Operating Considerations 4.................................................................
Mechanical 4........................................................................
Environmental 4......................................................................
Power Supply 4......................................................................
Input Connectors 4....................................................................
Certifications 4.......................................................................
Installing Modules 5.......................................................................
Powering the Instrument On and Off 6..........................................................
Creating an Emergency Startup Disk 7.........................................................
Adding a Second Monitor 8.................................................................
Changing the Windows Language 10...........................................................
Getting Acquainted with Your Instrument 12..........................................................
Front Panel 12...........................................................................
Rear Panel 12............................................................................
Interface 13.............................................................................
Control Panel 14..........................................................................
Display -- Single Graticule View 15.............................................................
Display -- Multiple Views 15..................................................................
Accessing Online Help 16...................................................................
Inspect Your Instrument 18......................................................................
Verify Internal Diagnostics Pass 18.............................................................
Optimizing Measurement Accuracy 20..............................................................
Signal Path Compensation 20................................................................
Perform Dark-Level and User Wavelength Gain Compensations 22......................................
Acquisition 24...............................................................................
Setting Up Signal Input 24...................................................................
Using Autoset 26
Using Default Setup 26.....................................................................
Accessing the Setup Dialog Boxes 27...........................................................
Changing the Acquisition Mode 28.............................................................
Setting the Display Style 29..................................................................
Triggers 30..................................................................................
Triggering Concepts 30.....................................................................
Trigger Event 30.......................................................................
Trigger Type 30.......................................................................
Trigger Modes 30......................................................................
Trigger Sources 30.....................................................................
Trigger Source Connectors 31.............................................................
Gated Trigger Connector (Option GT Equipped) 32..............................................
Enhanced Triggering 32.................................................................
Trigger Holdoff 32......................................................................
Setting Trigger Controls 34...................................................................
Setting Pattern Sync Controls 35..............................................................
Checking Trigger Status 36..................................................................
..........................................................................
Table of Contents
CSA8200 & TDS8200 Series Quick Start User Manual
i
Table of Contents
Analyzing Waveforms 37........................................................................
Taking Automatic Measurements 37............................................................
Turning Off Automatic Measurements 41.........................................................
Cursor Measurements 42....................................................................
Math Waveforms 44.......................................................................
Waveform Databases 46....................................................................
Display a Communication Signal 47............................................................
Display and Analyze Communication Signals Using Mask Testing 48.....................................
FrameScan 51...........................................................................
To Use TDR 52...........................................................................
Phase Reference 53.......................................................................
Histograms 54............................................................................
Document Your Results 55...................................................................
Using the 80A05 Electrical Clock Recovery Module Examples 56...........................................
Clock Recovery / Trigger on Recovered Clock 57...................................................
Clock Recovery / Trigger for Optical Signal, with the 80C12 Optical Module 58.............................
Differential Clock Recovery and Acquisition 59....................................................
Probing with Low-impedance Probes 60.........................................................
Probing with Differential to Single-ended Probes 61.................................................
Vertical Gain Adjustment 62..................................................................
Skew and Deskewing 63........................................................................
Sources of Skew 63........................................................................
Minimizing Skew 64........................................................................
Measuring Skew 64........................................................................
Methods to Deskew Your Signals 64............................................................
Methods to Adjust Out Skew 66...............................................................
Differential TDR Deskew Method 67............................................................
Configuration/Setup Considerations 67......................................................
Performing Acquisition Deskew 68..........................................................
Performing TDR Step Deskew 69..........................................................
Cleaning the Instrument 71......................................................................
Exterior Cleaning 71.......................................................................
Flat Panel Display Cleaning 71................................................................
Optical Connector Cleaning 71................................................................
Index 73...................................................................................
ii
CSA8200 & TDS8200 Series Quick Start User Manual

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.
To Avoid Fire or Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use.
Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a
voltage source.
Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric
shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
General Safety Summary
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult
the product manual for further ratings information before making connections to the product .
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Power Disconnect. The power switch disconnects the product from the power source. See instructions for the location.
Do not block the power switch; it must remain accessible to the user at all times.
Do Not Operate Without Covers. Do not operate this product with covers or panels removed.
Use Proper Fuse. Use only the fuse type and rating specified for this product.
Avoid Exposed Circuitry. Do not touch exposed connections and component s when power is present.
Wear Eye Protection. Wear eye protection i f exposure to high-intensity rays or laser radiati on exists.
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by
qualified service personnel.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation.
proper ventilation.
Refer to the manual’s installation instructions for details on installing the product so it has
Symbols and Terms
Terms in this Manual. These terms may appear in this manual:
CSA8200 & TDS8200 Series Quick Start User Manual
iii
General Safety Summary
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. The following symbols may appear on the product:
CAUTION
Refer to Manual
Mains Disconnected
OFF (Power)
WARNING
High Voltage
Mains Connected
ON (Power)
Protective Ground
(Earth) Terminal
Standby
iv
CSA8200 & TDS8200 Series Quick Start User Manual

Preface

Documentation
This manual describes the installation and operation of CSA8200 & TDS8200 Series Instruments along with basic operations and concept. For more detailed inf ormation, see the online help on your instrument.
NOTE. The screen images in this manual are based on product software version 2.5 and may differ slightly from other versions of product software.
Additional information is available through a variety of sources. The following information map points to the location of different types of information available for this product.
Quick Start User Manual WWW.Tektronix.com
Preface
Unpacking, Installation, Operation &
Overviews
Product
Documentation
CD
Demo
Applications
Software CD
PDF files of 8000 series
instrument & modules
Demo
Applications
Product Software
Product Software
Booklet
manuals
Verification and
Specifications
Documentation
Performance
Product
CD
In-depth Operation,
UI Help, Programming Help
Analysis & Connectivity Tools
Online Help
Analysis &
Connectivity Tools
Getting Started
with
OpenChoiceTM
Solutions Manual
System Restore
Software
System Restore
Booklet
Self-service
Optional Service
Manual
CSA8200 & TDS8200 Series Quick Start User Manual
v
Preface
Conventions Used in this Manual
The following icons are used throughout this manual.
Rear panel
power
Front panel
power
Connect pow-
er
Network PS2 SVGA USB
vi
CSA8200 & TDS8200 Series Quick Start User Manual

Key Features

The CSA8200 and TDS8200 Series instruments are high-speed, precision sampling systems that find use in validation and conformance testing and impedance verification for:
H High-performance semiconductor/computer applications, such as semiconductor testing, TDR characterization of
circuit boards, IC packages and cables, and high-speed serial digital data communications.
H High-performance communications applications, such as design evaluation and manufacturing test of datacom and
telecom components, transceiver subassemblies, and transmission systems.
The instruments include a user interface that runs on the Microsoft Windows 2000 operating system as a windowed application. You operate t he instrument using front-panel controls with the mouse and keyboard or with the touch screen.
Features Include:
H Industry-leading waveform acquisition and measurement rate, with Sample, Envelope, and Average acquisition m odes.
H Support for up to six sampling modules (two large and four small modules). Up to eight inputs can be active at a time.
H Supports integrated optical and/or electrical signal pick-off and clock recovery, enabling accurate triggering on optical
and/or electrical communication-signals.
Key Features
H Support for optical modules with several integrated, selectable reference receivers, which eliminates the need for a
multitude of add-on reference receivers.
H Full programmability, with an extensive GPIB-command set and a message-based interface.
H True differential TDR, with fast step (15 psec reflected risetime) when used with a TDR-capable 80E10 sampling
module.
H Industry-leading trigger bandwidth (12+ GHz) when using the built-in-prescaler.
H Support of both telecom (SONET and SDH) and datacom (Fibre Channel, Infiniband, and Gigabit Ethernet) optical
communication standards.
H Powerful built-in measurement capability, including histograms, mask testing, and automatic measurements.
H Automatic measurements operate on Pulses, RZ eye patterns, and NRZ eye patterns.
H DC to 65 GHz optical bandwidth; DC to 70+ GHz electrical bandwidth, with up to 12.5 GHz triggering.
NOTE. Bandwidth is determined by the specific modules that are installed.
H Low jitter (200 fs typical) in phase reference modes with the 82A04 Phase Reference module.
H FrameScan acquisition for isolating data-dependent failures during conformance/performance testing and for
examining very low-level repetitive signals.
H Jitter analysis with the 80SJNB Advanced Jitter, Noise and BER Analysis Software for the TDS/CSA8000 Series
Sampling Oscilloscopes application (requires software key). Refer to the 8000 Series Product Software CD-ROM booklet for free trial information and software key use.
H Pattern (frame) triggering with the 80A06 PatternSync Trigger module.
CSA8200 & TDS8200 Series Quick Start User Manual
1
Key Features
H Improved acquisition throughput and timing accuracy using the PatternSync Trigger module in conjunction with
H Support for optical conformance testing of SONET/SDH signals (including the various forward error correction rates for
NOTE. Support for conformance testing rates is determined by the specific modules that are installed.
H High precision time base with two modes of operation, locked and short-term jitter-optimized.
H Negligible long-term jitter degradation (<0.1 ppm), which substantially improves the ability to view signals that are
H Improved short-term and long-term trigger jitter.
H A gated trigger option (Option GT) that lets you disable or enable (gate) triggering based on a TTL signal you connect
H Analysis and connectivity tools enable the instrument to be controlled from a variety of local and remote environments
FrameScan.
these telecom rates) from 155 Mbps to 43 Gb/s, FibreChannel signal s, and 1, 2, and 10 Gigabit Ethernet signal s as well as 2.5 Gb/s I nfiniband signals.
delayed far from the trigger point without distortion.
to the instrument rear panel. This Option allows you to use recirculating buffers as part of your test setup to simulate the effects of very long optical links that are typical of undersea cables and long terrestrial links.
and to share data with other commercially available analysis programs.
H Predefined, built-in masks in addition to the user-defined masks.
H A large 10-inch color display that supports color grading of wavef orm data to show sample density.
H An intuitive UI (User Interface), with built-in online help displayable on screen.
2
CSA8200 & TDS8200 Series Quick Start User Manual

Install Your Instrum ent

Unpack the instrument and check that you received all items listed as Standard Accessories. Recommended accessories and probes, instrument options, and upgrades are listed in the online help. Check the Tektronix Web site (www.tektro­nix.com) for the most current information.

Standard Accessories

Accessory Tektronix part number
CSA8200 Communications Signal Analyzer TDS8200 Digital Sampling Oscilloscope Quick Start User Manual
Certificate of Traceable Calibration for product at initial shipment Not orderable
Business reply card Not orderable
1 Windows compatible keyboard 119-B146-00
1 Windows compatible mouse 119-6936-00
1 Instrument front cover 200-4519-00
Install Your Instrument
071-1482-xx
1 Accessory pouch 016-1441-00
2 Touchscreen styluses 119-6107-00
1 ESD wrist strap with 6 foot coiled cord 006-3415-04
CSA8000 & TDS8000 Series Product Documentation Kit (CD) 020-2543-xx
CSA8000 & TDS8000 Online Help (part of application software) Not orderable
CSA8000 & TDS8000 Programmer Online Guide (part of application software) Not orderable
Oscilloscope Analysis and Connecti vity Made Easy (manual and CD with connectivity examples)
CSA8000 & TDS8000 Series Windows 2000 OS Restore Kit 020-2527-xx
CSA8000 & TDS8000 Series Product Software Kit 020-2526-xx
8000 Series Demo Applications Software CD 020-2480-xx
1 Power cord Type dependent on
020-2449-xx
selection during order placement
CSA8200 & TDS8200 Series Quick Start User Manual
3
Install Your Instrument

Operating Considerations

The following information lists the specifications related to the operation of the mainframe. Refer t o the Specifications and Performance Verification manual for a complete list of specifications.
Mechanical
Clearance:
457 mm
(18 in.)
H Top, Front, and Rear: 0 in (0 mm)
H Sides: 2 in (51 mm)
H Bottom: 0.75 in (19 mm)
Weight:
H 19.5 kg (43.0 lb.). This does not include
343 mm
(13.5 in.)
any accessories or modules.
Depth = 419 mm (16.5 in.)
Environmental
Temperature 10 °Cto+40°C
Relative humidity 20% to 80%, with a maximum wet bulb temperature of 29 °Cator
below +40 °C
Altitude 3,000 m (approximately 10,000 ft.)
Power Supply
Source voltage and Frequency 100 -- 240 V
Power Consumption 240 watts (fully loaded); 160 watts (mainframe alone with no modules)
±10%, 50 -- 60 Hz or 115 V
RMS
±10%, 400 Hz
RMS
Input Connectors
Trigger Direct Input range ±1.5 V (DC + peak AC) maxi mum input voltage
Trigger Prescaled Input absol ute maximum
±2.5 V
p-p
input (typical)
External 10 MHz Reference Input 500 mV
Gated Trigger Input non-destruct levels
±5 V maximum
p-p
to5V
AC coupled into 1 kΩ, ±5 V maximum
p-p
(Option GT equipped mainframes)
Certifications
Pollution Degree Pollution Degree 2. Note: Rated for indoor use only.
4
CSA8200 & TDS8200 Series Quick Start User Manual

Installing Modules

CAUTION. Never install or remove modules while the instrument is powered on. Use an ESD wrist strap when installing or removing modules and when connecting signals to the module inputs. Do not transport or ship the instrument with modules installed.
1. Always use an ESD wrist strap (pro-
vided) when installing and removing modules.
2. Youcaninstalluptotwolargesam-
pling modules and four small modules for a total of 8 inputs.
Following are some typical module i nstallations illustrating the interaction between large compartment channels and small compartment channels.
Install Your Instrument
1
Small-module compartment (4)
Large-module compartment (2)
NOTE. A large compartment module that only derives power from the compartment does not use any small compartment input channels.
Eight channels: No large and four small modules
Six channels: Two large modules and two small modules
Seven channels: One large module, installed in CH3 compartment and three
CH1 Module not installed
CH 1 CH 2 CH 6CH 3 CH 8CH 5 CH 7
CH 1 N.A.
CH 2 N.A.
CH1 module not installed
CH 3 N.A.
CH 4
CH 4 N.A.
CH3 Module not installed
CH3 module installedCH1 module installed
CH 5 CH 7
CH 6
CH3 module installed
CH 8
small modules
CH 4 N.A.
CH 5 CH 7
CH 6
CH3 module not installed
CH 8CH 1 CH 2
Seven channels: One large module, installed in CH1 compartment and three
CH 3 N.A.
CH1 module installed
small modules
CH 1 N.A.
CH 2 N.A.
CH 4
CH 6CH 3 CH 8CH 5 CH 7
CSA8200 & TDS8200 Series Quick Start User Manual
5
Install Your Instrument

Powering the Instrument On and Off

1. Insert AC power cord.
2. Toggle the mains switch to on.
3. Use the front panel power button to
switch the instrument on and off.
12
3
Quick Tip
H When turning off the instrument, Windows and all applications automatically shut down before the instrument powers
off.
CAUTION. To prevent damaging the modules, do not install or remove any modules while the instrument is powered on.
6
CSA8200 & TDS8200 Series Quick Start User Manual

Creating an Emergency Startup Disk

Create an emergency startup disk that you can use to restart your instrument in case of a major hardware or software failure. Store this disk in a safe place.
1. Select the minimize icon, gaining
access to the Start menu.
2. Select Start > Programs >
Accessories > System Tools > Backup.
Install Your Instrument
1
2
3. Select Emergency Repair Disk and
follow the on-screen instructions.
3
CSA8200 & TDS8200 Series Quick Start User Manual
7
Install Your Instrument

Adding a Second Monitor

You can operate the instrument while using Windows and installed applications on an external monitor. Use the Settings tab in the Windows Display Properties dialog box to set up a dual-monitor configuration. Both the oscilloscope and the second monitor must have t he color setting set to True Color.
1. Power off the instrument.
2. Connect a video cable (not supplied)
from the video port on the back of the instrument to the external monitor.
1
External monitor
3. Power on the instrument.
4. Power on the external monitor.
2
3
4
8
CSA8200 & TDS8200 Series Quick Start User Manual
5. In the Start menu, select Settings and
then Control Panel.
6. Select Display.
7. In the Display Properties window, se-
lect the Settings tab.
Install Your Instrument
5
6
7
8. Select the second monitor.
9. Select Extend my Windows desktop
onto this monitor. Make sure t hat
both monitors are set to True Color.
10. Click Apply, and then click OK.
8
9
10
CSA8200 & TDS8200 Series Quick Start User Manual
9
Install Your Instrument

Changing the Windows Language

Use the following procedure to change the Windows language from English to one of your choice. This procedure does not change the language of the user interface or the onli ne help in the TekScope application. Before you begin, minimize the TekScope application.
1. Select Settings and then select Con­trol Panel.
2. Select Regional Options.
3. Select your locale, and then select
your menus and dialogs language.
4. Click Set default....
1
2
3
10
4
5. Select locale.
5
CSA8200 & TDS8200 Series Quick Start User Manual
6. Click Add to add the input locale.
7. Select the Input locale and Keyboard
layout/IME.
8. Select the Installed input locale, and
click Set as Default.
Install Your Instrument
6
7
9. Click OK.
10. Click Yes in each dialog box.
8
9
10
CSA8200 & TDS8200 Series Quick Start User Manual
11

Getting Acquainted with Your Instrument

Getting Acquainted with Your Instrument

Front Panel

Floppy disk drive
Control panel
Internal clock output
DC calibration output
External 10 MHz reference input
Trigger probe power
Trigger prescale input
On/Off switch Ground terminal
Trigger direct input

Rear Panel

CD-ROM drive
Removable hard drive
Audio line out
Audio line in (microphone)
USB (keyboard)
PS2 (keyboard)
PS2 (mouse) LAN COM 1
Parallel port
SVGA out for dual-monitor display
Scope VGA output for instrument display
GPIB
12
Gated trigger Option GT (lower right corner)
CSA8200 & TDS8200 Series Quick Start User Manual

Interface

The menu bar provides access to commands that control all of the instrument features and functions. The toolbar provides access to the most common features.
Hovering the cursor over button or setting displays a brief description of its function, called a tooltip.
Getting Acquainted with Your Instrument
Tool Bar: Access to key features: printing, setup dialogs, math setup, waveform database, autoset, clear data, acquisition mode, triggering, and applications
Menu Bar: Access to data I/O, printing, online help system, and set-up functions
Status Bar: Trigger status and waveform count
Measurements Bar:
Access to automated
measurements by signal
type and category; click
measurement buttons to
measure the selected
waveform
Display: Live, reference,
and math waveforms
display here, along with
cursors, masks, etc. to
analyze them
Waveform Bar: Access to waveform selection (click),
waveform position (drag),
and waveform properties
(right-click)
Controls Bar: Quick access to waveforms and timebases for display, and to their scale, offset, and position controls for adjustment
Readout Bar: Toggle individual readouts on and off by clicking its button
Phase Reference Status:
Indicates the characterization status of the phase reference module
A Readout: Right click any readout to display a short-cut menu providing handy access to often-used setup controls and properties for the feature associated with the readout
Readouts: Display up to five readouts in this area, selectable from the Readout Bar
Compensation Indicator: Indicates the compensation status of modules and mainframe
CSA8200 & TDS8200 Series Quick Start User Manual
13
Getting Acquainted with Your Instrument

Control Panel

Start and stop acquisition.
Adjust most control fields in setup dialogs. Press the Select button to switch among fields.
Press the Fine button to toggle between normal and fine adjustment.
Clear all channel waveforms at once.
Menu buttons quickly access the setup dialog for its control group for more detailed setup.
Display measurement cursors and assign the knob and Select buttons to control them.
Quickly return to instrument-default control settings.
Optimize instrument settings for selected channels.
Access print dialog for printing the display.
Display the cluster of Setup Dialogs for comprehensive
setup of the instrument.
Toggle the touch screen on and off. Use the touch screen
to control UI when you haven’t installed a mouse.
Select a waveform type, Channel, Reference, or Math, to
display or adjust on screen (selected button lights).
Select among displayed waveforms or display and select a
waveform. Press selected waveform to tun it off. Button
lights indicate displayed and selected waveforms.
Select among displayed timebase views or display and
select a timebase view. Press selected view to turn it off
(except main, which is always on).
Vertically scale, position, and offset selected waveform.
Horizontally scale, position, and set record length of
selected waveform.
Set trigger level and use lights to monitor trigger state.
14
CSA8200 & TDS8200 Series Quick Start User Manual
Loading...
+ 60 hidden pages