Declassication and Security
Instructions
www.tek.com
P077156200*
*
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O . Bo x 50 0 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worldwide, visit www.tek.com to nd contacts in your area.
Table of Contents
Preface .............................................................................................................. iii
Memory devices ............... ................................ ................................ ..................... 1
Clear or sanitize a non-functional instrument .. ... . .. . ... . ... .... ... . ... . .. . ... . ... . ... ... . ... . .. . ... . ... . ... ... 2
AWG-HDMI Declassication and Security Instructions i
Table of Contents
ii AWG-HDMI Declassication and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove memory devices from the Tektronix AWG-HDMI
There is no declassication specied for this product. The only information this device holds is factory calibration information for the delay times. There is no customer in
formation stored on the device and nothing can be accessed externally.
Reference
Required documents
Terms that may be used in
this document
The procedures in this document are written to meet the requirements specied in:
NISPOM, DoD 5220.22–M, Chapter 8
ISFO Process Manual for Certication & Accreditation of Classied Systems under NISPOM
No external documents are required to perform the procedures in this document.
The following terms may be used in this document:
Clear. This removes data on memory before reusing it in a secured area. All reusable memory is cleared to deny ac ces s to previously stored information by standard means of access.
Instrument Declassication. A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment. Declassication procedures include memory sanitization and memory removal, and sometimes both.
Nonvolatile memory. Data is retained when the instrument is powered off.
Remove. This is a physical means to clear the data by removing the memory
device from the instrument. Instructions are available in the product Service Manual.
Sanitize. This eradicates the data from media/memory so that the data cannot be recovered by other means or technology. This is typically used when the device will be moved (temporarily or permanently) from a secured area to a non-secured area.
User Accessible. User is able to directly retrieve the memory device contents.
Volatile memory. Data is lost when the instrument is powered off.
AWG-HDMI Declassication and Security Instructions iii
Preface
Device terms
User data. Desc waveforms or other measurement data representing signals connected to the instrument by users.
User settings. Describes the type of information stored in the device. Refers to instrument settings that can be changed by the user.
Both. Describes the type of information stored in the device. It means that both user data and user settings are stored in the device.
None. Describes the type of information stored in the device. It means that neither user data nor user settings are stored in the device.
Directly. Describes how data is modied. It means that the user can modify the data.
Indirectly. Describes how data is modied. It means that the instrument system resources modify the data and that the user cannot modify the data.
ribes the type of information stored in the device. Refers to
iv AWG-HDMI Declassication and Security Instructions
Memory devices
Volatile memory devices
Type
of user Type and min. size Function
1GB SDRAM
Holds current delay and voltage values
System memory
Non-volatile memory
info
stored
Delay
value
and
voltage
offset
value
devices
There is no declassication specied for this product. The only information this device holds is factory calibration information for the delay times. There is no customer information stored on the device and nothing can be accessed externally.
Backed up by battery
No Directly
Method of modication
and indirectly
Data Input method Location
Visa commands (Direct)
System memory written by processor system (Indirect)
SBC (Single Board Computer)
User accessible To clear To sanitize
User can access delay and voltage values via Visa, but nothing else
Remove power from the instrument foratleast20 seconds.
Remove power from the instrument for at least 20 seconds.
Type and min. size Function
SanDisk Industrial Micro SD Card
8GB
Holds AWG-HD control software and
ration
calib values
Typ e of user info stored
None Indirectly Factory
MI
Method of modication
Data Input method Location
congu
ration
Micro SD slot on internal SBC (Single Board Compu
ter)
User accessible To clear To sanitize
No Not applicable.
t contain
Does no user data or settings.
ing
Clear would disable instrument
ionality.
funct
Not applicable.
t
Does no contain user data or settings.
ing
Clear would disable instrument
ionality.
funct
AWG-HDMI Declassication and Security Instructions 1
Clear or sanitize a non-functional instrument
Clearorsanit
Charges
ize a non-functional instrument
If your instr No user data is stored on the instrument when the power is removed. Clearing or sanitizing the instrument is not applicable.
Replacemen the time of replacement.
ument is not functioning, return the instrument to Tektronix for repair.
t of any missing hardware will be charged according to the rate at
2AWG-HDMIDeclassification and Security Instructions