skew between ±.......................................................................................................6
Table of Content
s
AWG-HD Specifications and Performance Verificationi
Table of Content
s
iiAWG-HD Specifications and Performance Verification
Important safet
y information
Important saf
This manual contains information and warnings that must be followed by the user for safe operation and to keep the
product in a safe condition.
To safely perform service on this product, additional information is provided at the end of this section. (See page v,
Service safety summary.)
ety information
General safety summary
Use the product only as speci fied. Review the following safety precautions to avoid injury and prevent damage to this product
or any products connected to it. Carefully read all instructions. Retain these instructions for future reference.
This product shall be used in accordance with local and national codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition
to the safety precautions specified in this manual.
The product is designed to be used by trained personnel only.
Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or
adjustment.
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other
component manuals for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
To avoid fire or personal injury
Use proper power cord.
Do not use the provided power cord for other products.
Ground the product.
shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output
terminals of the product, make sure that the product is properly grounded.
Do not disable the power cord grounding connection.
Power disconnect.
Do not position the equipment so that it is difficult to operate the power cord; it must remain accessible to the user at all
times to allow for quick disconnection if needed.
Observe all terminal ratings.
the product manual for further ratings information before making connections to the product.
Use only the power cord specified for this product and certified for the country of use.
This product is grounded through the grounding conductor of the power cord. To avoid electric
The power cord disconnects the product from the power source. See instructions for the location.
To avoid fire or shock hazard, observe all ratings and markings on the product. Consult
Do not operate without covers.
Hazardous voltage exposure is possible.
AWG-HD Specifications and Performance Verificationiii
Do not operate this product with covers or panels removed, or with the case open.
Important safet
y information
Do not operate with suspected failures.
qualified servi
Disable the pr
the product, turn it off and disconnect the power cord. Clearly mark the product to prevent its further operation.
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specified replacement parts.
ce personnel.
oduct if it is damaged. Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of
Do not operate in wet/damp conditions.
warm environment.
If you suspect that there is damage to this product, have it inspected by
Be aware that condensation may occur if a unit is moved from a cold to a
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Provide proper ventilation.
obstructed. Use the product in its temperature rating. Do not push objects into any of the openings.
Slots and openings are provided for ventilation and should never be covered or otherwise
Provide a safe working environment.
and indic
Avoid im
may result in serious injury.
ators.
proper or prolonged use of keyboards, pointers, and button pads. Improper or prolonged keyboard or pointer use
Remove the input signals before you clean the product.
Always place the product in a location convenient for viewing the display
Be sure your work area meets applicable ergonomic standards. Consult w ith an ergonomics professional to avoid stress
injuries.
Use care when lifting and carrying the product.
WARNIN
carrying the product.
WARNING. The product is heavy. Use a two-person lift or a mechanical aid.
Use only the Tektronix rackmount hardware specified for this product.
G. The product is heavy. To reduce the risk of personal injury or damage to the device get help when lifting or
ivAWG-HD Specifications and Performance Verification
Servicesafetysummary
The Service safety summary section contains additional information required to safely perform service on the product. Only
qualified personnel should perform service procedures. Read this Service safety summary and the General safety summary
before performing any service procedures.
Important safet
y information
To avoid electric shock.
Do not service alone.
rendering first aid and resuscitation is present.
Disconnect power.
power before removing any covers or p
To avoid electric shock, switch off the product power and disconnect the power cord from the mains
Use care when servicing with power on.
power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing
components.
Verify safety after repair.
Terms in this manual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Do not touch exposed connections.
Do not perform internal service or adjustments of this product unless another person capable of
anels, or opening the case for servicing.
Dangerous voltages or currents may exist in this product. Disconnect
Always recheck ground continuity and mains dielectric strength after performing a repair.
Symbols and terms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
When this symbol is marked on the product, be sure to consult the manual to find out the nature of the
potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used
refer the user to ratings in the manual.)
The following symbol(s) may appear on the product:
AWG-HD Specifications and Performance Verificationv
to
Preface
Preface
The Tektronix AWG-HD is an HDMI fixture for sink (Rx) testing with programmable delay and amplitude. This document
provides the electrical, mechanical, and environmental specifications for this product, as well as the procedures for
performance verification.
Related documents available on www.tek.com
AWG-HD Prog
TekE xpres s
as a downloadable PDF at www.tek.com.)
AWGSYNC01 Safety and Installation Manual
AWG70000 Series Help (Available from the AWG70000 Series instrument Help menu and as a downloadable PDF at
www.tek.com.)
AWG-HD Specifications and Performance Verification Technical R eference
TekExpress® eARC Solution Application Help (Available from the TekScope menu in the TekExpress application and
as a downl
rammer Manual
® FRL Solution A pplication Help (Available from the TekScope menu in the TekExpress application and
oadable PDF at www.tek.com.)
viAWG-HD Specifications and Performance Verification
Specifications
Specification
All specifications are guaranteed unless labeled Typical. Typical specifications are provided for your convenience.
NOTE. Warranted characteristics that are checked in the Performance Verification are marked with a
The performance limits in this specification are valid within the following conditions:
Software version installed on the AWG-HD is 2.2 or greater.
Operate the instrument in an environment that meets the temperature, altitude, and humidity characteristics listed in
these specifications.
s
symbol.
AWG-HD Specifications and Performance Verification1
Specifications
System characteristics
Frequency res
Min skew between ±
Typical skew between ±, typical±300 ps
Max voltage swing
Min voltage
DC gain, typical
DC offset accuracy, typical
Input/Output impedance50 ±5 Ω
Number of outputs
Number of inputs
Connector typeSMALocated on the front panel.
ponse
swing
Physical characteristics
+1 dB to -2.5 dB, 0 to 8 GHz
+1 dB to -5 dB, 0
±250 psMinimum intra-pair skew achievable
1.5 V
80 mV
0 to 3.5 VVoltage range that each channel
< ±100 mV
8, all identical
8, all identical
pk-pk
m
pk-pk
to 18 GHz
in
max
Test frequency response tolerance
and amplitude
for a single c
Typical intr
a single channel.
Maximum voltage swing (amplitude).
Minimum voltage swing (amplitude).
can operat
configuration.
The DC accuracy of the offset of the
system.
The resistance at each input and
output.
Located on the front panel.
Located on the front panel.
flatness.
hannel.
a-pair skew achievable for
e under typical HDMI
t
Weigh
nsions
Dime
Height
Width
Depth
Power characteristics
Power supply
Power consumption<120 W
11.34kg(25lbs)
mm (3.5 in)
88.9
.45 mm (16.75 in)
425
0.5 mm (7.5 in)
19
100 - 240 VAC
0/60 Hz
5
2AWG-HD Specifications and Performance Verification
Environmental performance
Temperature
Operating+10 °C to +30 °C (+50 °F to +86 °F)
Nonoperatin
Humidity
Operating5% to 90% RH (
Nonoperating
Altitude
Operating3000 meters (9842.5 feet)
Nonoperating
g
–10 °C to +50 °C (14 °F to +122 °F)
relative humidity) up to + 30 °C (+86 °F), non-condensing
5% to 45% RH
12000 meters (39370 feet)
above +30 °C to +50 °C (+86 °F to 122 °F), non-condensing
Specifications
AWG-HD Specifications and Performance Verification3
Performance ver
ification
Performance v
NOTE. The performance verification procedure is not a calibration procedure. The performance verification procedure
only verifies that your instrument meets key specifications.
erification
Prerequisites
Thetestsinthissectionmakeupaconfirmation of performance and functionality when the following requirements are met:
Operate the instrument in an environment that meets the temperature, altitude, and humidity characteristics listed in
the specifications.
The instrument must be completely assembled and covers installed per factory specification.
Required equipment
These pro
the equipment required for this procedure.
ItemQtyModel exampleTest
Real-ti
oscilloscope, ≥23 GHz
BW
cedures use external, traceable signal sources to directly check warranted characteristics. The following table lists
me
1Tektron
DPO72304SX or other SX model ≥23 GHz
BW
ix
All EXCEPT Frequency Response
Signal generator, max
freq >18 GHz, low
noise
phase
Power splitter1
meter
Power
Cable, SMA
(low loss, phase
ble)
sta
Torque wrench18 in-lbsAll
NOTE. Make sure that any adaptor and cable you use is specified to operate at the frequency range of the test you
are performing. Connector frequency ranges:
SMA: DC to 18 GHz typical, up to 26.5 GHz for certain SMA cable/connectors.
1
1
5
Anritsu MG3694B
Anritsu K241CAll EXCEPT Frequency Response
Rhode and Schwartz NRV-Z1 head (10M –
18GHz) with the URV35 base power meter
ronix 0130-314-00
Tekt
All
ency Response
Frequ
All
4AWG-HD Specifications and Performance Verification
Frequency response
This test verifies the frequency response of the unit to verify it can operate at the expected frequency range. Tests will need
to be run at every channel of the unit, both positive and negative legs. It is measured by inputting a sinusoidal wave into the
input of the device, sweeping across frequency while measuring the amplitude at the output with a power meter to check for
amplitude flatness relative to a reference frequency of 100 MHz.
Signal Generator input setup
1. Connect the signal generator RF OUT to the AWG-HD CH1– IN with a SMA cable.
2. Set the amplitude to 0 dBm.
3. Set the generator to output a sine wave.
Output to power meter setup
1. Connect the power meter input to the AWG-HD CH1+ Out with a SMA cable.
NOTE. The DUT is a pass-through that inverts the input signal, so anything plugged in to a positive IN channel will come out
of the negative OUT channel and vice versa.
Performance ver
ification
Test
1. Launch TekVISA and establish communication with the AWG-HD unit.
2. Send the OUTPUT ENABLE command to the AWG-HD to turn the output on.
3.Set the signal generator as follows. Ensure the path (generator, cables, power meter) is characterized for accurate
ts.
resul
ency: 100 MHz
Frequ
tude: 0 dBm
Ampli
4. Turn
5. Send
6. Reco
7. On the signal generator, increment the frequency by 100 MHz and then measure the amplitude again.
on the output of the signal generator.
the ZERO command to the AWG-HD so that all channels have the same delay.
rd the amplitude (dBm) reading of the power meter.
s will be used as your reference at 100 MHz. All future readings will be measured in reference to this value to
Thi
check the frequency response.
AWG-HD Specifications and Performance Verification5
Performance ver
8. Continue incrementing in 100 MHz steps up to 18 GHz. Measure and record the amplitude for each step in the test record.
9. Once finished, repeat the test with each of the following input configurations and record the results in the test record:
ification
Input: CH1+IN, Output: CH1–OUT
Input: CH2 +IN, Output: CH2 –OUT
Input: CH2 –IN, Output: CH2 +OUT
Input: CH3 + IN, Output: CH3 –OUT
Input: CH3 –IN, Output: CH3 +OUT
Input: CH4 +IN, Output: CH4 –OUT
Input: CH4 –IN, Output: CH4 +OUT
Minimum sk
This test ve rifies the maximum intra-pair s kew attainable between the positive and negative leg of each channel. The
minimum requirement for this is ±250 ps. To test this, the DUT delay must be centered and the value entered will be
the maximum skew.
Signal Generator input setup
1. Connect a SMA cable to the signal generator RF OUT.
2. Connect a power splitter to the other end of that SMA cable.
3. Connect 2 SMA cables, one to each output, of the power splitter.
4. Connect the ends of the SMA cables from the splitter to the AWG-HD CH1 +IN and CH1 –IN.
5. Set the amplitude to 0 dBm.
6. Set the frequency to 2.112 GHz.
7. Set the generator to output a sine wave.
ut to oscilloscope setup
Outp
1. Connect CH1 of the oscilloscope to CH1 +OUT of the AWG-HD.
2. Connect CH2 of the oscilloscope to CH1 –OUT of the AWG-HD.
ew between ±
Test
unch TekVISA and establish communication with the AWG-HD unit.
1. La
nd the OUTPUT ENABLE command to the AWG-HD to turn the output on.
2. Se
6AWG-HD Specifications and Performance Verification
Performance ver
3.Set the signal generator as follows. Ensure the path (generator, cables, power meter) is characterized for accurate
results.
ification
Frequency: 2.
Amplitude: 0 d
4. Turn on the out
5. Set volts/di
6. Add a Delay me
7. Determine i
a. Find the firs
b. Look at the fi
channels. If they are, proceed to step 8. If not, proceed to step 7 c.
c.Add a horizontal delay to the start of the acquisition if the trigger points are misaligned.
8. Average >100000 acquisitions and note the skew (rounded to half a ps).
9.Send the STEP command to the AWG-HD on CH:1 with the value of the skew previously measured.
10. Increase the frequency on the signal generator to 4.112 GHz.
11. Run another acquisition on the oscilloscope.
12. Record the skew and send the STEP command to the AWG-HD on the corresponding channel with the value of the skew
(rounded to half a ps). Wait 1 second, clear, and then run another acquisition on the oscilloscope.
112 GHz
Bm
put of the signal generator.
v to full scale and the sampling rate to 50 GS/s on the oscilloscope.
asurement between CH1 and CH2 on the oscilloscope.
f you need to calibrate the horizontal delay for the first measurement as follows:
t edge trigger point of the acquisition.
rst and second edge trigger points and check that the cursors are at the same 50% point for both
13. If centered (<2 ps skew), send a DEL query on the corresponding channel. The returned number is the minimum skew
between
14. Record
15. Perfor
to the channel being measured. For example, when measuring CH2, use the CH:2 DEL command.
16. Record the results in the test record.
±.
the results in the test record.
m this test on the other three channels of the AWG-HD. Make sure to change the commands sent to the AWG-HD
AWG-HD Specifications and Performance Verification7
Performance ver
ification
Max/Min voltage swing
This test verifies the maximum and minimum voltage swing attainable by the device.
Signal Generator input setup
1. Connect a SMA cable to the signal generator RF OUT.
2. Connect a power splitter to the other end of that SMA cable.
3. Connect 2 SMA cables, one to each output, of the power splitter.
4. Connect the ends of the SMA cables from the splitter to the AWG-HD CH1 +IN and CH1 –IN.
5. Set the amplitude to 500 mV.
6. Set the frequency to 6.112 GHz.
7. Set the generator to output a sine wave.
Output to
1. Connect CH1 of the oscilloscope to CH1 +OUT of the AWG-HD.
2. Connect CH2 of the oscilloscope to CH1 –OUT of the AWG-HD.
oscilloscope setup
Test
1. Launch
2. Send t
3. Send t
4.Set th
5. Turn on the output of the signal generator.
6. Set Volts/div to full scale and the sampling rate to 50 GS/s on the oscilloscope.
7. Add an amplitude measurement for the waveforms for each channel in order to calculate the maximum voltage swing.
8. Add the two amplitudes and record the result in the test record. This is the maximum voltage swing. Record this
TekVISA and establish communication with the AWG-HD unit.
he OUTPUT ENABLE command to the AWG-HD to turn the output on.
he ZERO command to the AWG-HD so that all channels have the same delay.
e signal generator as follows. Ensure the path (generator, cables, power meter) is characterized for accurate
results.
Frequency: 6.112 GHz
Amplitude: 500 mV
value in the test record.
9. To measure the minimum voltage swing, set the amplitude of the signal generator to 35 mV.
10. Add the two amplitudes and record the result in the test record. This is the minimum voltage swing. Record this value
the test record.
in
epeat this procedure on CH2, CH3, and CH4.
11.R
8AWG-HD Specifications and Performance Verification
Test record
Use the attached spreadsheet to record test results for all of the tests provided in this document. To access the spreadsheet,
view and then download the attachment in this PDF.
Performance ver
ification
AWG-HD Specifications and Performance Verification9