Tektronix AWG701AUP, AWG702AUP User manual

xx
AWG701AUP AWG702AUP Options 01, 03, and SSD
ZZZ
AWG70000A Series Upgrades
Instructions
www.tektronix.com
*
075-1049-02
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O . Bo x 5 0 0 Beaverto USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200. Worl d wide , vis i t www.tektronix.com to nd contacts in your area.
Service safety summary
Only qualied personnel should perform service procedures. Read this Service safety summary before performing any service procedures.
Do not service alone. Do not perform internal service or adjustments of this product unless another person capable of rendering rst aid and resuscitation is present.
Disconnect power. To avoid electric shock, switch off the instrument power, then disconnec
Use care when servicing with power on. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
t the power cord from the mains power.
AWG70000A Series Upgrades 1
Service safety summary
2 AWG70000A Series Upgrades
Upgrade kit overview
This document provides instructions for performing hardware and/or software and option key upgrades on the following Tektronix products:
AWG70001A Arbitrary Waveform Generators
AWG70002A Arbitrary Waveform Generators
Upgrade kits covered by
these instr
AWG70001A Upgrades
AWG701AUP 01 Increases the waveform record length from 2 GSamples to 16 GSamples Option key only
AWG701AUP 03
AWG701AUP SSD Provides an additional (or replacement) preprogrammed Solid State Drive
AWG70002A Upgrades
AWG702AUP 01 Increases the waveform record length from 2 G Samples to 8 GSamples
AWG702
AWG70
AWG70
AWG7
AWG7
AUP 03
2AUP 0816
2AUP 0825
02AUP 1625
02AUP SSD
uctions
The following table lists the available product upgrades supported by this document.
Description Upgrade type
Adds sequencing
Description Upgrade type
on both
Adds sequencing
Incre
Incre
Incr
Prov
channels
ases the sampling rate from 8 GS/s to 16 GS/s
ases the sampling rate from 8 GS/s to 25 GS/s
eases the sampling rate from 16 GS/s to 25 GS/s
ides an additional (or replacement) preprogrammed Solid State Drive
Some upgrades only require an option key to enable the new features.
Option key only
Hardware included
Option key only
key only
Option
n key only
Optio
n key only
Optio
on key only
Opti
Hardware included
For a list of available options, see the Tektronix Web site (www.tektronix.com) or your Tektronix representative.
AWG70000A Series Upgrades 3
Upgrade kit overview
Kit parts lists
Option key only upgrades
AWG701AUP SSD and
AWG702AUP SSD
Some upgrades only require a new option key to enable the new features or enhancements. These types of kits contains the following items:
Tektronix part number Qty. Description
N/A
1
LABEL, OPTION KEY INFORMATION
Apply label to rear panel
N/A
1
LABEL, ECCN (RED)
Only supplied with:
AWG701AUP 03
AWG702AUP 03
Apply label to rear panel
075-1049-XX 1
MANUAL, KIT INSTRUCTIONS
This upgrade provides a preprogrammed solid state drive to use as either a secondary hard drive or as a replacement for a failed hard drive. The kit contains the following items:
Tektronix part number Qty. Description
211-1081-XX
335-2612-XX
407-5641-XX
650-5875-XX
075-1049-XX 1
1
Th
2
Early instruments used the hard drive part numbered 650–5585–XX. This upgrade kit provides the correct hard drive based on your instrument’s serial number.
1
4
SCREW, MACHINE; M3 X 0.5 X 3.5MM, FLAT WAFER HD W/SERRATIONS STRESS RELIEVED, PHL, ZINC PLATED STEEL
1
1
MARKER, IDENT; HD ADAPTER (S LED); SAFETY CONTROLLED
1
1,2
1
1
ASSEMBLY, SLED, HARD DRIVE MOUNT (REMOVABLE)
HARD DRIVE, PROGRAMMED; SOLID STATE DRIVE PROGRAMMED W/ OS & APP SW
MANUAL, KIT INSTRUCTIONS
e hard drive and the mechanical sled components are pre-assembled.
4 AWG70000A Series Upgrades
Upgrade kit installation
Refer to the one (or more) of the following installation sections pertaining to the upgrade(s) you are installing.
Minimum tool and equipment list
No special tools are required to install any of the upgrade kits covered by these installati
Option key only upgrades
on instructions.
Upgrade kit installation
To ins t a l this kit. This unique key number is valid only for the specic model number and serial number of your instrument; it will not work on any other instrument. This single key number enables all valid options for your instrument, those that were factory installed and any others that you may have already purchased. In other words, this new key number supersedes any previous key numbers that you may
CAUTION. To avoid losing your options, do not misplace the label that is included
with this kit. This label contains the option installation key number and should be installed on the rear panel of the instrument for future reference. Apply the new label over the existing option key label.
As a backup, you may want to copy the key number and save it with the other important papers for your instrument. If you ever need to re-enable the option, you will need to re-enter this key number.
1. Power on the instrument.
2. Select Utilities from the workspace tabs.
3. Select About my AWG to display the current option information and system
l these types of options, you need the key number that is provided with
already have.
information.
AWG70000A Series Upgrades 5
Upgrade kit installation
4. Click Install Options to start the upgrade installation process.
5. Click Continue from the Install Upgrades introduction screen.
6. Enter the option key provided by Tektronix, and follow the on-screen
tructions to install the option.
ins
7. Power off the instrument, then power back on.
8. Select Utilities from the workspace tabs.
9. Select About my AWG to display the current option information and system
information.
10. Verify the new option is listed.
6 AWG70000A Series Upgrades
Upgrade kit installation
11. Apply the new option key label over the existing key label on the rear panel of the instrument.
12. Option 03 upgrades (adding sequencing): You must apply the red ECCN label to the rear panel of the instrument.
AWG70000A Series Upgrades 7
Upgrade kit installation
AWG701AUP SSD AWG702AUP SSD
and
installation
NOTE. Before installing the new hard drive, use an external backup device to
back up any les on your instrument for use on the new hard drive.
Install the hard drive using the following procedure:
1. Power off t
2. Loosen the thumb screws and remove the existing hard drive.
NOTE. The
3. Install the new hard drive, and then tighten the thumb screws to secure the drive in the instrument.
4. Power on the instrument to verify operation.
he instrument.
hard drive and hard drive sled c omponents are pre-assembled.
8 AWG70000A Series Upgrades
Verify instrument software version
Verify instru
ment software version
Tektronix re your instrument.
1. Select Util Software Version number.
2. Use your We
3. Search for your instrument’s model number and follow the link to the software.
4. If the installed software is older than that available, download the software.
5. Follow the instructions on the Web page to install the software.
NOTE. Updating the instrument software does not impact installed option keys.
commends to update to the latest available application software for
ities > About my AWG. Under System Information, note the
b browser to go to: www.tektronix.com/software.
AWG70000A Series Upgrades 9
Loading...