Tektronix AWG5202, AWG5204, AWG5208 Online Help

xx
AWG5200 Series
ZZZ
Arbitrary Waveform Generators
Printable Help Document
Revision A
*
P077133400*
AWG5200 Series Arbitrary Waveform Generators
ZZZ
Printable Help Document
w.tek.com
ww
077-1334-01
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Microsoft, Windows, and Windows 7 are registered trademarks of Microsoft Corporation.
MATLAB is a registered trademark of The Mathworks, Inc.
Supports Product Software Version 6.1 and above.
Help part number: 076–0406–01
PDF of Help system part number: 077–1334–01
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P. O . B o x 5 0 0
rton, OR 97077
Beave USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. Worldwide, visit www.tek.com to find contacts in your area.
Table of Contents
Introduction
Introduction ......................................................................................................... 1
Productsoftware.................................................................................................... 2
Documentation...................................................................................................... 2
Support information ................................................................................................ 3
Analysis and connectivity support................................................................................ 4
WorkingwiththeAWG
AWG mode window
AWG mode general overview................................................................................ 5
AWG workspace tabs.......................................................................................... 6
Runstate control .............................................................................................. 15
Screen interface features via touchscreen and mouse..................................................... 15
Toolbar ......................................................................................................... 19
Waveform list
Working with the waveform list............................................................................. 21
Adding a waveform........................................................................................... 23
Saving a waveform ........................................................................................... 28
Apply corrections............................................................................................. 28
Assign a waveform to a channel ............................................................................ 29
Modify waveform............................................................................................. 31
Modify markers............................................................................................... 35
Waveform properties ......................................................................................... 38
Applying waveform corrections
Applying correction fil
Apply S-Parameters
Apply S-Parameters...................................................................................... 41
S-Parameter file descriptions....................................................................... 44
Aggressor signals ................................................................................... 46
Sequence list
Sequence list .................................................................................................. 46
Adding a sequence............................................................................................ 47
Saving a sequence ............................................................................................ 49
Assigning tracks to a channel................................................................................ 49
Edit a sequence................................................................................................ 51
Sequenceproperties .......................................................................................... 52
General setup
General setup overview ...................................................................................... 53
Table of Contents
e................................................................................. 40
AWG5200 Series Arbitrary Waveform Generators Printable Help Document i
Table of Contents
Enable all channels on play.................................................................................. 53
Apply recommended settings on assignment .............................................................. 54
Channel setup
Channel setup introduction .................................................................................. 54
Enable outputs / relay state .................................................................................. 55
Channel output path .......................................................................................... 57
Amplitude ..................................................................................................... 57
Markers ........................................................................................................ 60
Resolution(bits) .............................................................................................. 61
Couple channel settings ................................ .. .. . . . . . . ............................................ 61
Channel color.................................................................................................. 63
Output Options
DAC Options
I/Q Modulator
Clock setup
Clock introduction............................................................................................ 69
Sample Rate ................................................................................................... 69
Clock and Reference Sources ............................................................................... 70
Clock output................................................................................................... 73
Trigger setup
Trigger control ................................................................................................ 73
Trigger input settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................................. 76
Trigger timing................................................................................................. 78
Skew setup
Adjust skew ................................................................................................... 80
Sync (synchronization)
Sync (synchronization)overview........................................................................... 84
Setup for multiple instrument synchronization (Real and IQ waveforms) ............................. 85
Measurement for alignment ................................................................................. 89
Obtaining synchronization after instrument setup......................................................... 92
8 instrument synchronization instructions example....................................................... 93
Synchronization troubleshooting.......................................................................... 105
Synchronization of IQ waveforms in NCO mode....................................................... 107
IQ waveform synchronization example .................................................................. 107
Output Options........................................................................................... 63
DAC Options............................................................................................. 65
I/QModulator ............................................................................................ 67
How long does alignment take?...................................................................... 105
Actionsthat cause loss-of-sync....................................................................... 105
Actions that result in a change in sync timing (but changing back restores original sync
timing).............................................................................................. 106
Actionsthat do notcause loss of sync............................................................... 106
ii AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Table of Contents
Aux Out setup
Aux Out setup ............................................................................................... 111
Sequence Editor
Sequencetab overview..................................................................................... 111
Sequences - creating and editing
Editing tools ............................................................................................ 112
Sequencecreate andedit toolbar..................................................................... 114
Copy and paste guidelines ............................................................................ 118
Sequence settings
Sequence settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . ....................................... 118
Forcing jumps
Forcing jumps introduction ........................................................................... 119
Force Jump To... button............................................................................... 120
Force jumphere........................................................................................ 122
Jump timing
Jump timing ............................................................................................ 122
Pattern jump
Creating a Pattern jump ............................................................................... 123
Jump priority
Jump execution order.................................................................................. 125
Flags
Sequenceflags.......................................................................................... 126
Subsequence editing
Subsequence editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...................................... 128
Sequencer batch compiler
Sequencer batch compiler............................................................................. 129
Capture and Playback
Capture/Playback introduction ............................................................................ 136
Captured Signal List
Adding (impo
Removing Signals...................................................................................... 138
Editing signals.......................................................................................... 139
Adding signals from files
Adding signals from files ............................................................................. 141
Capturing signals from instruments
Capturing signals from instruments.................................................................. 143
Connecting to an oscilloscope ......... .. .. .. . . . . . . . . . . . . . . . . . . . . . . .............................. 144
Connectingto a spectrum analyzer.............................................................. 145
Compiling I/Q signals
Compiling I/Q signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................................... 147
Waveform plug-ins
Waveform plug-ins introduction .......................................................................... 149
rting) IQ data files ..................................................................... 137
AWG5200 Series Arbitrary Waveform Generators Printable Help Document iii
Table of Contents
Basic waveform
Equation editor
Table editor
Precompensation plug-in
Precompensation plug-in................................................................................... 189
Waveform requirements
Waveform specifications and notes ....................................................................... 190
File formats (creating)
File formats (creating)...................................................................................... 190
Sequence file format
Waveform file format
Matlab waveform file format
Basic waveform ........................................................................................ 150
Equation editoroverview ............................................................................. 153
Limitations.............................................................................................. 155
Tips on using the equation editor..................................................................... 155
Basic keywords
Basic keywords.................................................................................... 157
Waveform functions
Waveform functions .............................................................................. 158
Correlation ......................................................................................... 164
Code conversion................................................................................... 166
Differentiation..................................................................................... 170
Integration.......................................................................................... 172
Convolution........................................................................................ 173
Math functions
Math functions..................................................................................... 174
Math operators
Math operators..................................................................................... 175
Equation examples
Equation examples ................................................................................ 176
Table editor ............................................................................................. 185
Sequence file format (.seq)............................................................................ 191
Waveform file format (.wfmx)........................................................................ 193
MATLAB waveform file format...................................................................... 198
MATLAB waveform file example ................................................................... 201
MATLAB IQ file example ............................................................................ 202
Controls and connectors
Front-panel controls and connectors
Front-panel controls ........................................................................................ 205
Front-panel connectors..................................................................................... 206
iv AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Rear panel connectors
Rear-panel connectors...................................................................................... 207
Working with Functions
Functions home window overview ............................................................................ 211
Diagnostics
Diagnostics ....................................................................................................... 213
Calibration
Calibration........................................................................................................ 217
Enhancements and plug-ins
Enhancements for your instrument ............................................................................ 219
Licensing
Licensing overview.............................................................................................. 221
How to purchase a license...................................................................................... 221
How to install a license ......................................................................................... 223
How to return a license ......................................................................................... 224
Table of Contents
Index
AWG5200 Series Arbitrary Waveform Generators Printable Help Document v
Table of Contents
vi AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Introduction Introduction
Introduction
Your Arbitrary Waveform Generator (AWG) combines world-class signal fidelity with ultra high-speed mixed signal simulation and a graphical user interface. The easy-to-use interface is built on the Microsoft Windows plat such as networked instruments.
AWG and Fu nctions mode selection
Thegeneratorhastwomodesofoperation, the Arbitrary Waveform Generator (AWG) mode and the Functions mode. Access to either mode of operation is from the Home tabs of your instrument by selecting either the AWG or Functions button.
form and is fully compatible with a wide range of PC hardware and software accessories,
AWG displays the arbitrary waveform generator Home screen with access to all AWG controls, playing any waveshape from a file.
Functions displays the Home screen with controls to generate basic waveshapes, such as sine waves, square waves, and triangle waves.
The AWG and Functions modes work independently from each other, but they both use the Analog Output connectors to play out their waveforms.
Controls
eral methods of controlling the instrument are provided.
Sev
Capacitive touchscreen interface.
Use the touchscreen to control all operations of the instrument. Or use in conjunction with a mouse, keyboard, and front-panel controls. You can enables or disable the touchscreen from the Utilities
enu. The capacitive touchscreen is designed to operate with direct skin contact or use of a capacitive
m type stylus.
Keyboard and mouse
Front-panel controls
Remote control via the programmable interface
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 1
Introduction Product software
External display
Enhanced viewing of the AWG display is easily accomplished by attaching an external monitor to the VGA connector provided on the rear of the instrument.
By default, the VGA output is set to duplicate the AWG’s display, but you can use the Windows display controls to change how the instrument uses an external display.
Product software
The instrument includes the following software and related documents:
System software
The system software is a specially configured version of Microsoft Windows and enables you to install other compatible applications. For instructions on how to restore Microsoft Windows, refer to the Installation and Safety manual that is shipped with your instrument. Do not attempt to substitute any version of Windows that is not specifically provided by Tektronix for use with your instrument.
Product software
The product software is the instrument application and runs on Microsoft Windows. It provides the user interface (UI) and all other instrument control functions.
Release notes
The release notes contain information on updates and known issues that are not included in other product documentation.
Documentation
The following table lists the primary documentation available for this product.
All listed documents are available on the Tektronix website (http://www.tek.com/manual/downloads
To read about Use these documents
Installation and Safety Read the Installation and Safety manual for general information about
Operation and user interface help Access the application help from the Help menu for information on all
, which is preinstalled
).
how to prepare your instrument for use and basic operating instructions. This manual is provided with the instrument.
Tektronix part number 071-3529-xx.
controls and on-screen elements. The application help is part of the product software.
A PDF of the help system is available, Tektronix part number 077-1334-xx.
2 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Introduction Support information
To read about Use these documents
Programming commands
Specications and performance verication procedures
xxx
Access the programmer manual for the syntax of remote control commands.
Tektronix part number 077-1337-xx.
This technical reference document provides the complete instrument specications. Procedures are provided to verify the instrument is operating to
Tektronix part number 077-1335-xx.
the warranted specications.
Support information
Tektronix offers the following services in support of their products:
Technical Support. For application-related questions about a Tektronix product, see Contacting
Tekt roni x.
Service Support. For service-related questions about a Tektronix product, see Contacting Tektronix.
Tektronix also offers extended warranty and calibration programs as options on many products. Contact your local Tektronix distributor or sales office.
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 3
Introduction Analysis and connectivity support
Analysis and connectivity support
Tektronix Windows-based arbitrary waveform generators support industry-standard software tools, applications and protocols. The integrated Windows desktop of these models enables popular commercial programs or c
The instrument includes tools that you can install to support data import or export for use with data-analysis tools. The f
TekV ISA
TekVISA is a library of industry-standard compliant software components, organized according to the standard VISA model established by the VXIplug&play Systems Alliance. Use TekVISA in software to write i and your instrument.
ustom-written applications to run on the instrument.
ollowing tools are supported:
nteroperable instrument drivers to handle communicating between software applications
TekV ISA connectivity will be impaired or disabled.
VXI-11
The VXI 11.2 LAN Server provides software connectivity between your instrument and remote PCs over an you must install another copy of TekVISA to make use of its client-side component.
IVI Dr
IVI drivers conform to specifications produced by the IVI Foundation. IVI drivers provide a standard inte
Tektronix IVI-COM driver supports easy waveform transfer from third party software, such as MAT
must be the only VISA type software installed. If other VISA software is installed,
.2 LAN Server
Ethernet LAN. This tool is a client-side component built-in with TekVISA on each remote PC;
ivers
rface to different classes of instruments, including oscilloscopes and spectrum analyzers.
LAB.
4 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG AWG mode general overview
AWG mode general overview
Selecting the AWG mode button displays the controls for operating the arbitrary waveform generator.
Toolbar (see page 19): contains tools to access help, restore the interface layout, and work with
setups, open and save files.
Workspace tabs (see page 6): contain tabs to change the workspace view (which includes the
graphical waveform display area).
Home tab contains the waveform plot area and various controls for quick access.
Setup tab c
Waveform Plug-ins tab contains the selections for optional waveform creation applications.
Abasicwa
Capture/Playback tab contains the controls to import baseband I/Q data files (captured from an instr for playout. You can also import files created with other tools such as MATLAB.
Utilit
Precompensation tab contains the settings to create correction files to be used with a
wavef plug-in, it must be licensed.
/Stop button (icon)
Play
the same as the front-panel Play/Stop button.
/Functions buttons: switches the instrument between the arbitrary waveform generator (AWG)
AWG
mode and the basic waveshape generator (Functions) mode. The workspace tabs change in conjunction with the selected instrument modes.
Waveform List (see page 21) and Sequence List (see page 46): contains the waveforms and
sequences available for use.
Status area: displays user messages to indicate possible problems or status.
ontains the settings to control the channel outputs, clocks, and triggers.
veform creation application is included as a standard plug-in.
ument such as a spectrum analyzer or oscilloscope) and compile them into a waveform
ies tab contains system, preferences settings, and instrument information.
orm file. The Precompensation plug-in must be installed to display this tab.Tousethe
(see page 15): starts and stops the playout of a waveform. This function is
ll outputs off button: provides you with an easy way to quickly disconnect all analog, marker, and
A
flag outputs. (The output connectors are electrically floating.)
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 5
Working with the AWG AWG workspace tabs
AWG workspace tabs
The AWG workspace panel is the main working area for setting up and controlling waveform playout.
s at the top of the screen display different views and settings.
Tab
Home tab (with waveforms) (see page 7)
Displays waveform, cursors, markers
Provides buttons for waveform output control
Provides quick access to triggering
6 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG AWG workspace tabs
Home tab with wave forms
Home tab (with sequence) (see page 8)
Displays the sequence track assigned to the channel
Provides buttons for waveform output control
ides quick access to force a jump to another location in the sequence
Prov
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 7
Working with the AWG AWG workspace tabs
Home tab with sequence
Home tab (with IQ waveform) (see page 9)
ys both the I and Q components of an IQ waveform
Displa
Displays center frequency
NOTE.
IQ waveforms and real waveforms cannot be assigned to channels at the same time.
To display and play an IQ waveform, the digital up-converter (DIGUP) must be licensed.
8 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG AWG workspace tabs
Home tab with IQ waveform
Setup tab (see page 9)
Adjust Channel settings
Adjust Clock settings
Adjust T
Adjust relative timing of output signals
Define Auxiliary outputs (Flags)
Enable instrument to instrument synchronization
rigger settings
Setup tab
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 9
Working with the AWG AWG workspace tabs
Waveform plug-ins tab (see page 11)
Standard waveform plug-in applications are located here, which includes:
Basic Waveform editor
Equation Editor
Table Edito
NOTE. The standard waveform plug-ins are documented in this help system. Optional waveform plug-ins have their own unique help systems.
Optional waveform plug-in applications are added here.
NOTE. Optional waveform plug-ins have their own unique help systems are not documented in this help system. Use the help button within the Waveform Plug-ins tab to access the Optional waveform plug-in’s help system.
Create different types of waveforms based on selected waveform plug-in
r
10 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG AWG workspace tabs
Waveform Plug-ins tab
Sequence Editor tab (see page 12)
encing (SEQ) license required)
(Sequ
Create sequences
Edit existing sequences
Enable Pattern Jump and specify the pattern jump table
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 11
Working with the AWG AWG workspace tabs
Sequence editor tab
Capture/Playback tab (see page 12)
Import baseband IQ waveforms and up-convert imported waveforms to RF waveforms.
Acquire the acquired waveforms to RF waveforms.
live baseband IQ waveforms from an oscilloscope or spectrum analyzer and up-convert
Capture/Playback
12 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG AWG workspace tabs
Utilities tab (see page 13)
Utilities
Diag & Cal button: Displays the dialog screen to show the current state of the diagnostics and calibration. The instrument incorporates a temperature sensor that continuously monitors the instrument’s internal temperature. If the internal temperature changes more than 5 °C from its previous calibration temperature, a status message appears requesting that you to perform
-calibration. You can run the calibration routine at any time if your application requires
a self optimum performance. See Calibration See Diagnostics
System button: System provides information about the instrument’s GPIB address and Security controls.
The GPIB Address setting lets you set the instrument’s identity when using a GPIB converter for the programmable interface. Refer to the AWG5200 Series Programmers manual for complete details about the programmable interface.
Security controls allow you to lock the instrument’s display screen. When locked, all front-panel controls are disabled except for the power button.
(see page 213) for more information about performing diagnostic routines.
(see page 217) for more information about self-calibration.
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 13
Working with the AWG AWG workspace tabs
You can also choose to disable the ability of the external SourceXpress application to connect and control the instrument. SourceXpress has the ability to connect to, and control, the instrument directly from
Preferences button: Preferences provides access to (brightness controls, error message controls, and text size).
Enable or disable the touchscreen
it's interface.
Choose to hide the pop-up error messages, forcing the errors to only show in the Status ba the bottom of the screen.
Brightness Controls lets you adjust the intensity levels of the display screen and the front-panel LEDs.
Choose to reduce the size of the text and elements of the user interface.
Help & Support button: Help & Support provides links to where you can obtain additional product help and documentation.
About my AWG button: About my AWG provides you with detailed information about your instrument, such as installed options, licenses, and the product’s software version. This information is helpful when contacting Tektronix about your instrument. Use the Copy Instrument Info button to copy and paste the instrument information into another application suchasanemailprogram.
The Install License and Return License buttons are used to manage licensing for product upgrades and optional plug-in applications. See Enhancements for your instrument
Precompensation tab (see page 14)
(see page 219).
Precompensation
rat
The Precompensation tab allows you to create correction files to be used with a waveform file.
14 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG Run state control
NOTE. The Precompensation tab only appears if the Precompensation plug-in is installed. To use the plug-in, it must be licensed. Refer to Licensing
(see page 221).
The Precompensation tab has its own user help (and is not described here). Press the help button on the Precompensation tab to access its user manual.
Run state control
You start and stop the waveform playout using the Play button. For a waveform to be output through the Analog Output connector, the Channel output must be enabled.
The condition of the outputs (output level or disconnected) when waveform playout has been stopped or is waiting for a trigger event, is defined in the Output Options
Run state status indicators
The play button in the graphical interface changes appearance to indicate the waveform playout status. Below are the various indicators.
(see page 63) dialog box.
Table 1:
Not lighted – stopped (or idle) with no waveforms being played.
Green with sinewave – currently playing a waveform.
Green with T symbol – waiting for a trigger event to begin waveform playout.
Yellow with clock symbol – the instrument is busy and playout is temporarily inhibited.
Red – An error is preventing the waveform playout.
xxx
The front-panel Play button also indicates the playout status with variouscolors. SeeFront-panel controls
(see page 205) for a description of its status indicators.
Screen interface features via touchscreen and mouse
The graphical user interface (GUI) is designed with some features that are only accessible via the touchscreen or right and left mouse clicks.
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 15
Working with the AWG Screen interface features via touchscreen and mouse
Left mouse clic settings
Pull down list
Numerical settings
control
s
kon
Touch (or left m
Selections with a triangle incorporate a pull-down list. Touch (or left mouse click) on the triangle to display the list.
A setting t (or right mouse click) the setting.
The settings menu allows you to quickly set the value to its default, minimum, or maximum values. Cutting, c setting the value to the nearest valid value.
Some settings allow you to change the units used for the setting. For instance, amplitude can be set in Vpp
ouse click) on any control or setting selects or activates that control.
hat requires a numerical value has an additional menu accessed by touching and holding
opying, and pasting values is allowed. Pasting an invalid value results with the instrument
or dBm. Phase adjustments can be set in degrees or time.
Drag and drop
Use the touchscreen (or left mouse) to drag a waveform or a sequence (from the waveform list or
ence list) onto the waveform display area. Existing waveforms or sequences are replaced.
sequ If the previous waveform or sequence was currently playing, the new waveform or sequence starts playing immediately.
16 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG Screen interface features via touchscreen and mouse
Zooming
Use the touchs you want to expand.
Zoom In: Drag the zoom box from left to right to zoom in on that section of the waveform.
The boxed por
Zoom Out: Dra
the graph.
You can also use the
creen (or left mouse click) to drag a zooming box over the portion of a waveform
tion is centered in the graph.
g the zoom box from right to left zoom out. The boxed portion is centered in
icon to quickly r eturn the waveform to its full display.
When zoomed in, you can pan through the waveform using the scroll bar below the waveform.
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 17
Working with the AWG Screen interface features via touchscreen and mouse
Waveform menu The waveform g
Touch and hold the touchscreen (or right mouse click) anywhere in the waveform area to display the waveform menu.
Show cursors toggles the measurement cursor display on or off (default is off). You can drag the cursors i cursor display control affects all channels.
Show Analog toggles the waveform d isplay on or off (there is no default setting). If the waveform display is off, it remains off until it is turned back on. The analog waveform display control is i
Show Marker default. See the Resolution (bits) display control is independent for each channel.
Y Axis toggles the vertical graph axis between Volts and Normalized (default is Volts). The Y Axis contr
X Axis togg Axis control affects all channels.
Grid display (default is off). The grid display control affects all c hannels.
ndependent for each channel.
ol affects all channels.
raphical area contains a menu for various actions.
nto position or enter their position directly in the waveform display area. The
s lets you select which markers you want to display or hide. Markers are off by
(see page 61) setting to enable markers. The markers
les the horizontal axis between Seconds and Samples (default is Samples). The X
18 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Working with the AWG Toolbar
Window panel resizing
Undocking and docking t
abs
The various window panels can be adjusted in size where-ever two panels are divided. Touch and hold the to or decrease the panel size.
Any tab ca completely separate it from the main GUI. Touch and hold the touchscreen (or left mouse click) to grab a tab and slide it to a new area. The docking icon displays that you can use to choose how you want t
uchscreen (or right mouse click) to grab the 3 dot indicator and slide to increase
n be undocked from the GUI. This allows you to reposition a tab to a new location or
o dock (reposition) the tab.
e Reset Window Layout button
Use th settings.
xxx
(in the Toolbar) to return the display to the factory
Toolbar
The toolbar (see page 21) provides access to various setup actions.
NOTE. The AWG mode and Functions mode utilize the same Toolbar. Any action taken by the tools
ttons affects both modes. For example, restoring the default setup affects both the Functions mode
bu and AWG mode.
AWG5200 Series Arbitrary Waveform Generators Printable Help Document 19
Working with the AWG Toolbar
Table 2:
Open File allow
A windows Open dialog box opens to the most recent location accessed. Use this window to navigate to saved les. In the Open dialog box, you can set the window to display all supported le types or re
The action taken depends on the le type opened.
Setup files: Opening a saved setup le returns the instrument to the settings saved with the
setup le. Waveforms and/or sequences saved with the setup le are also restored, removing
all existing waveforms and sequences.
Waveform les: Opening a waveform le from the toolbar allows you to select one waveform
le at a time to load into the Waveform List. (Matlab les that contain more than one waveform
will have all waveforms loaded into the Waveform List. See Adding a waveform
for more information.
Sequence les: Opening a sequence le from the toolbar allows you to select one sequence
le at a time to load into the Sequence List. If the sequence le contains subsequences, these
are also placed in the Sequence List. All waveforms used in the sequence are loaded into the
Waveform list. See Adding a sequence
A windows Open dialog box opens to most recent location accessed. Use this window to navigate to your les.
The factory location is C:\Program Files\Tektronix\AWG5200\Samples.
For more advanced options to add waveforms or sequences, use the Open icons located within the Waveform List and Sequence List panels.
Save Setup saves the current settings as a setup le, allowing you to easily return the instrument to a known setup. A windows Save As dialog box opens to the most recent location accessed. Use this window to navigate to where you want to save the setup le.
In the Save As window, you can choose to save the setup le (which includes all waveforms and sequences) or save the setup le without the waveforms or sequences.
Choosing to save the setup le with waveforms and sequences also saves the waveforms listed in the Capture/Playback signal list.
s you to open any of the supported le types.
strict the w indow to display a certain type of le.
(see page 23)
(see page 47) for more information.
The factory location is C:\Program Files\Tektronix\AWG5200\Samples.
The Play/Stop button starts and stops the playout of a waveform in both the AWG mode and the Functions mode. This operates the same as the front-panel Play/Stop button.
button changes appearance to indicate the current playout status. Refer to Run state control
The
(see page 15).
20 AWG5200 Series Arbitrary Waveform Generators Printable Help Document
Loading...
+ 210 hidden pages