Instruction Manual
650-A900-00 Preamplifier for the WCA200,
RSA200, RSA2200A, RSA3300A, and
RSA3400A series
WCA200/RSA200/RSA2200A/RSA3300A/
RSA3400A
зѪȼкᡑ
650-A900-00 ിїѪТѳї
075-1266-01
www.tektronix.com
075126601

Copyright © Tektronix, Inc. All rights reserved.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supercedes that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

Product Overview
The 650-A900-00 preamplifier is designed for use with the WCA200 series Wireless Communication Analyzer, the RSA200, RSA2200A, RSA3300A,
RSA3400A series Real-Time Spectrum Analyzer.
The preamplifier has 100 MHz to 3 GHz frequency range and 20 dB gain. Power is
supplied to the preamplifier through the PRE AMP power connector on the front
panel of the WCA200, RSA200, RSA2200A, RSA3300A, or RSA3400A series
instrument. The WCA200, RSA3300A, and RSA3400A series have the power
connector on standard. The RSA200 and RSA2200A series need to add the power
connector with Option 06 and Option 2A, respectively.
Frequency characteristics and gain compensation data are provided with each instrument. The data is provided as 3.5 inch floppy disk, you can install the data to the
WCA200, RSA200, RSA2200A, RSA3300A, and RSA3400A series. The instrument displays adjusted values, you need no additional data conversion.
Standard Accessories
H Power Cord (Tektronix part number: 012-A227-00)
Preamplifier power is supplied from the WCA200/RSA200/RSA2200A
/RSA3300A/RSA3400A series instrument.
H 3.5 inch floppy disk (Tektronix part number: 062-A293-XX)
Gain and frequency characteristics data is included.
Install this data to the WCA200/RSA200/RSA2200A/RSA3300A/
RSA3400A series.
H Certificate of Calibration
H Instruction manual (Tektronix part number: 075-1266-XX)
650-A900-00 Preamplifier Instruction Manual
1

Installation
Installation
NOTE. For the WCA230/280 and RSA230/280, the installation function is only
available for the instrument with firmware version 1.28 and above.
Do the following steps to perform the amplitude correction by using the provided
floppy disk. For detailed information on amplitude correction, refer to the user
manual for the WCA200, RSA200, RSA2200A,RSA3300A or RSA3400A series.
The 650-A900-00 preamplifier is designed to connect directly into the instrument
as shown in the figure below (the RSA200 and RSA2200A series need to add the
power connector with Option 06 and Option 2A, respectively).
1. Power off the instrument.
2. Install the 650-A900-00 preamplifier to the WCA200/RSA200/RSA2200A
/RSA3300A/RSA3400A series input connector. Turn the N-connector ring
when you install the preamplifier.
NOTE. Do not turn the body of preamplifier when you install it to the instrument. Take care not to place the connector too tight. Do not put a stress on the
amplifier body.
3. Attach the amplifier power cord.
4. Power on the instrument.
2
650-A900-00 Preamplifier Instruction Manual

Installation
5. Wait until operating system is loaded and the system is ready.
6. Press the front panel AMPLITUDE key.
7. Press the Correction... side key.
8. Insert the floppy disk (062-A293-XX) to the floppy disk drive of the
instrument.
For WCA230A/280A, RSA2203A/2208A, RSA3303A/3308A and RSA3408A
9. Press the Load Table side key. A file selection list appears.
10. Press the Folder side key and select the floppy drive (A:).
11. Press the Done side key.
12. Turn the rotary knob to select the amplitude correction file.
13. Press Load File Now side key to load the file.
14. After the loading, remove the floppy disk from the floppy disk drive.
15. Press Amplitude Table side key and select On.
The acquired data will be compensated and the waveform will be displayed. The
loaded data will be deleted if you press the AMPLITUDE
ʪ Correction... ʪ
Edit Table ʪ Clear Table side keys or simply press the PRESET key.
For WCA230/280 and RSA230/280
16. Press the Load side key. A file selection list appears.
17. Press the Change Directory side key repeatedly and select the amplitude
correction file from drive A.
18. Turn the rotary knob to select the amplitude correction file.
19. Press Enter side key to load the file.
20. After the loading, remove the floppy disk from the floppy disk drive.
21. Press Setup... side key.
22. Press Correction side key and select On.
The acquired data will be compensated and the waveform will be displayed. The
loaded data will be deleted if you press the AMPLITUDE
Edit... ʪ Reset side keys or simply press the PRESET key.
650-A900-00 Preamplifier Instruction Manual
ʪ Correction... ʪ
3