Tektronix 4299-2 Installation Manual

Keithley Instruments
Model 4299-2 Dual-Unit
2
Hinge
2602-328
2
Front rack-ear
2602-355
2
Rear rack-mount bracket
2602-334
2
Rack-mount extension arm
2602-335
1
Rear bracket
2304-327
1
Quick-release pin
FA-352
8
Cage nut
FA-274
2
#6 Lock washer
6LKWA
2
Washer
WA-81
4
#8-32 × 3/8 in. Phillips pan-head screw
8-32×3/8PPH
4
#8-32 × 3/8 in. Phillips flat-head screw
8-32×3/8PFH
4
#10-32 × 3/8 in. Phillips pan-head SEMS screw
10-32×3/8PPHSEM
2
#6-32 × 5/8 in. Phillips pan-head screw
6-32×5/8PPH
2
M4 × 12 mm Phillips pan-head screw
M4×12PPH
28775 Aurora Road Cleveland, Ohio 44139 1-800-833-9200
tek.com/keithley
Rack-Mount Kit Installation Instructions

Introduction

The Model 4299-2 Dual-Unit Rack-Mount Kit contains the hardware required to mount two half-rack instruments in a standard 48.3 cm (19 in.) rack. Typical installation is for two Series 2600A or 2600B System SourceMeter instruments or one Series 2600A or 2600B instrument with another half-rack instrument.

Parts list

Refer to the table below for a list of parts included in the kit.
Quantity Description Keithley part number
®
8 #10-32 × 5/8 in. Phillips truss-head screw 10-32×5/8PHTRSH
2 M4 × 12 mm Phillips flat-head screw M4×12MMPFH

Tools required

Medium (#2) Phillips screwdriver
3/8-inch wrench
Flat-bladed screwdriver or cage-nut installation tool
PA-909 Rev. J April 2021 *PPA-909J* 1
Model 4299-2 Dual-Unit Rack-Mount Kit Installation Instructions

Installation overview

Review the Installation precautions (on page 2).
Select a location in the rack:
a. Clear as much space as possible around the selected rack location. b. Remove the cabinet side panels from the rack.
Prepare the instrument (on page 3
Install mounting hardware (on page 4).
Prepare the rack (on page 7).
Install the instruments (on page 9) in the rack.

Installation precautions

Observe the following safety precautions while installing instruments.
Turn off instrument power and unplug all cables before installing an instrument in a rack. Failure to remove power before installation may cause personal injury or death from electrical shock.
).
Heat sources should be mounted away from the instrument, cabling, and accessories, with sufficient space provided between the instrument and heat source for airflow and cooling.
To prevent damaging heat build-up and ensure specified performance, make sure there is adequate ventilation and airflow around the instrument to ensure proper cooling. Do not cover the ventilation holes on the sides or back of the instrument. The rear vents and both side vents must be unobstructed to properly dissipate heat.
Mount precision equipment as low as possible in the rack. Operating temperatures are cooler lower in the rack.
2 PA-909 Rev. J April 2021
Model 4299-2 Dual-Unit Rack-Mount Kit Installation Instructions

Prepare the instrument

To remove the handle, mounting ears, and rear feet:
1. Gently pull the handle (1) away from the sides of the instrument case and swing it up or down until the orientation arrows on the handles line up with the orientation arrows on the mounting ears, as shown in the following figure.
Figure 1: Rack-mount kit handle removal
2. After you align the arrows (2), pull the ends of the handle (1) away from the case.
3. Remove the screw that secures each mounting ear (3).
4. Pull down and out to remove each ear.
Figure 2: Mounting ear removal
5. From the bottom of the instrument, pull out the rubber feet and remove the screws (4), see the following figure.
Figure 3: Instrument rubber feet removal
6. Store the handle, rubber feet, and hardware for future use.
PA-909 Rev. J April 2021 3
Model 4299-2 Dual-Unit Rack-Mount Kit Installation Instructions

Install mounting hardware

Install the mounting hardware on the opposite sides of each instrument, as shown in the following figures.
To install the mounting hardware on the instruments:
1. Place the instruments side-by-side, in the same position that they will be installed in the rack.
2. Secure one rear rack-mount bracket (2602-334) to each instrument on the selected side using two Phillips pan-head SEMS screws (#10-32 × 3/8 PPHSEM).
If the two instruments are not the same length, do not use one of the rear rack-mount brackets. Refer to Install the instruments (on page 9 detail. Additionally, save all unused parts for future use.
), "To install two instruments that are of unequal length" for more