016-1983-01, 016-1985-01, and 016-1988-01 and above
ZZZ
Rackmount Kits
Instructions
Warning
The servicing instructions are for use by qualified personnel
only. To avoid personal injury, do not perform any servicing
unless you are qualified to do so. Refer to all safety summaries
prior to performing service.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14200 SW Karl Braun Drive
P.O . B ox 5 0 0
Beaverto
USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200.
World wide, vis i t www.tektronix.com to find contacts in your area.
Service Safety Summary
Only qualified personnel should perform service procedures. Read this Service
Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is
present.
Disconnec
disconnect the power cord from the mains power.
UseCareWhenServicingWithPowerOn. Dangerousvoltagesorcurrentsmay
exist in this product. Disconnect power, remove battery (if applicable), and
disconnect test leads before removing protective panels, soldering, or replacing
compon
To avoid electric shock, do not touch exposed connections.
tPower. To avoid electric shock, switch off the instrument power, then
ents.
016-1983-xx, 016-1985-xx, and 016-1988-xx Kits1
Service Safety Summary
2016-1983-xx, 016-1985-xx, and 016-1988-xx Kits
Kit Description
Products
This document supports Tektronix DPO7000, DPO70000/B, DSA70000/B,
MSO70000, and AWG7000 Series instruments. The rackmount kit is a collection
of parts that, once installed, configure the instrument for mounting into a standard
19-inch equipment rack.
DPO7000 SeriesAll (configuration 1)
DPO70000/B SeriesAll (configuration 2)
DSA70000/B SeriesAll (configuration 2)
MSO70000 SeriesAll (configuration 2)
AWG7000 SeriesAll (configuration 3)
AWG5000 SeriesAll (configuration 3)
Minimu
m Tool and Equipment List
Kit Parts List
Required tools and equipmentPart number
Screw Driver, Phillips, #2Standard tool
T-15 T orx tip
Screwdriver handle (magnetic)Accepts 1/4 inch hex-head driver tips
Torx-driver tip for T-15 size screw heads
The following table lists the parts for each kit. You receive the parts for only the
kits you ordered.
t
Ki
All1 each075-0904-05Technical manual, i nstructions
016-1983-xx
016-1985-xx
016-1988-xx
antity
Qu
1 each016-1983-xx
1 each
each
2
1 each016-1985-xx
1 each
2 each
1 each016-1988-xx
1 each
2 each
rt number
Pa
–
–
–
–
–
–
scription
De
Rackmount kit consisting of the following:
Rackmount kit
ack, Trim plate
R
Rackmount kit consisting of the following:
Rackmount kit
Rack, Trim plate
Rackmount kit consisting of the following:
Rackmount kit
Rack, Trim plate
016-1983-xx, 016-1985-xx, and 016-1988-xx Kits3
Kit Description
Warranted Cha
racteristics
When the instrument is installed according to the instructions in this document, the
rackmounted instrument meets all warranted requirements listed in the instrument
specificatio
these instructions might not meet their warranted requirements.
For tables o
and performance verification manual that applies to your instrument model.
Cooling ai
responsibility to provide adequate cool air to meet the ambient temperature
requirements listed in the specifications.
Clearance Requirements
The rack in which the rack adapted instrument is mounted must provide the
following clearance requirements:
n. Instruments mounted using methods other than those described in
f the warranted characteristics, see Specification in the specification
r enters on the bottom as shown in Figure 1. You assume the
Configuration 1 and 2, a minimum of 3 11.15 mm (12.25 in) of vertical space.
Configuration 3, a minimum of 266.7 mm (10.5 in) of vertical space.
Amini
rails in the rack.
mum width of 450 mm (17.717 in) between the left- and right-front
imum inside depth of at least 520.7 mm (20.5 in).
Amin
CAUTION. Adhering to these requirements mounts the rack-adapted instrument
with sufficient clearance for air circulation and accommodation of the power
cord and mounting hardware. Failure to provide these clearances can result in
overheating and can cause the instrument to operate improperly or fail.
4016-1983-xx, 016-1985-xx, and 016-1988-xx Kits
Kit Description
Figure 1: Clearance requirements
016-1983-xx, 016-1985-xx, and 016-1988-xx Kits5
Installation Instructions
Installation Instructions
These instructions are for qualified service personnel who are familiar
with servicing the product. If you need further details for disassembling or
reassemblin
your nearest Tektronix, Inc., Service Center or Tektronix Factory Service for
installation assistance.
Remove
Remove the handle and trim as shown. (See Figure 2.)
g the product, refer to the appropriate product manual. Contact
Figure 2: Remove handle and trim
6016-1983-xx, 016-1985-xx, and 016-1988-xx Kits
Install
Installation Instructions
Install the adapter bracket in your rack platform as s hown in the following figures.
NOTE. Configuration 3 has additional spacer rails.
Install the adapter bracket.
NOTE. Install the adapter bracket only if you plan to install a Teklink Hub.
Figure 4: Assembly installation (configurations 1 and 2 shown)
8016-1983-xx, 016-1985-xx, and 016-1988-xx Kits
Reassemble
Installation Instructions
1. Remove the rack slides. (See Figure 5.)
Figure 5: Removing the rack slides (configurations 1 and 2 shown)
016-1983-xx, 016-1985-xx, and 016-1988-xx Kits9
Installation Instructions
2. Attach the rack
slides to your equipment rack. (See Figure 6.)
Figure 6: Installing the rail slides
10016-1983-xx, 016-1985-xx, and 016-1988-xx Kits
Installation Instructions
3. Install the rac
the slides as shown. (See Figure 7.)
k platform in y our equipment rack by inserting the platform into
Figure 7: Installation of rack plate assembly in rack (top view) (configurations 1
and 2 shown)
WAR N ING. To avoid personal injury, prevent the instrument from tipping or
ping, two or more people should install this instrument into the rack cabinet.
drop
After completing the installation procedure, verify that the instrument and the
rack cabinet will not tip forward while the instrument is in the extended position.
Do not leave the instrument extended when finished accessing the instrument.
016-1983-xx, 016-1985-xx, and 016-1988-xx Kits11
Installation Instructions
Figure 8: Installing the instrument on the rack plate
4. Install your instrument on the rack plate as shown. (See Figure 8.)
5. Install the power cord. Provide access to a power plug or mains disconnect
switch for turning the instrument on/off.
6. Optionally install any cables you need connected to the instrument rear or
side panels.
7. Slide the instrument into the equipment rack.
12016-1983-xx, 016-1985-xx, and 016-1988-xx Kits
Installation Instructions
8. Install the app
ropriate trim plates as shown. (See Figure 9.)
Figure 9: Installation of trim plate
End of document