Teknim TSD-701 Mounting And User Manual

TSD-701 /
Ceiling Type Gas Detector
Mounting and User Manual
Issue Date: 29/09/2016 R:01
IMPORTANT WARNINGS
Before using the device read this
manual carefully. Keep it just in case of necessity.
Abide all the rules and precautions stated in the
manual. Follow all the instructions one by one.
Keep the devices away from water and moisture
CONDITIONS
Do not energize the device above or below the given limits of extreme hot or cold conditions,
Temperature: Between 0C and +55C Relative Moisture: %0- 95 concentrated
SERVICE
In case of any malfunction or below conditions contact with your authorized service,
When Mains cable or the plug is harmed, Contact of device with a fluid, Exposure of rain and water, Fell down of device or harmed outer cover, Serious performance fall on the device, Depending on the instructions stated in manual, if
your device not working properly, further usage or possible wrong usage may cause other malfunctions. Contact with your authorized service in such terms.
INFORMATION RELATING TO USAGE ERRORS
Do not allow to change the opening or setting up your device by unauthorized persons. As a result of such a situation, your device can start working differently compared to the first case.
SECURITY CHECK
Please ask your dealer to check that the service is working properly and safe conditions.
.
TO BE CONSIDERED AND CONSUMER CAN DO TO MAINTAIN, REPAIR AND CLEANING
- Do not attempt to repair the device yourself, because if you open the oven door or tampering can be exposed to possible electric shock or cause a malfunction of the device.
- If a fault occurs, please contact your dealer or authorized service center. Device technical intervention must be carried out by authorized service personnel qualified.
- The device should be cleaned with a damp cloth. Never spray, polish, do not use any chemicals such as detergents.
- Alcohol, thinner, cologne, sprays, lighter too intense, pungent cleaning agents do not mislead the device to false alarms and may cause deterioration of the detector. In addition, gas detection holes must be clean and dry.
TRANSPORTATION
Device must be carefully transported avoiding all physical bump, stroke and possible fluid entry. Malfunctions that caused by improper transportation is not under warranty.
Model
TSD-701
Supply Voltage Type IP Rating Compatible Standard
12-24 VDC A IPX2D TS EN 50194-1
Contact Output
1 pcs, NC or NO
Startup Time
3 minutes
Normal Condition Led Color
Green
Error Condition Led Color
Yellow
Alarm Condition Led Color
Red
Alarm Level (Natural gas)
%10 LEL
Output Relay
30 V DC, 50mA
Alarm Output Alarm Buzzer Sound Level
Solid State Relay + Voice and flashing leds 85 dB
NO
NC
EQUIPMENT LOCATION SELECTION, INSTALLATION AND CONNECTION
1. To mount your device must be performed by authorized person.
2. Selecting the mounting location of the device:
- From any device powered by natural gas will be far away at least 1.5 meters from the projection of a place.
- In case of a gas leak it would be a likely place to be the most accumulation of gas.
- The detector will NOT be over direct cooked meals, sink and toilet bowl (which should be at least 1.5 meters away).
- The detector will NOT be adjacent Aspirator, fan and ventilation (which should be at least 1.5 meters away).
3. Remove the head of the detector attached to base by turning it counter clock wise until you reach the short line on the base (1), then pull it off (2).
4. Use at least 2 opposite ones from 4 of the screw holes on the base to fasten it.