Tekbox TBS06-TS, RS232 User Manual

V1.0
TBS06
-TS
RS232 to
SDI-12
Interface
Fibox
- and Dinrail
TBS06-TS
RS232 to SDI-12 converter and bus sniffer
The TBS06-TS (DR) RS232 to SDI-12 Converter is an interface for connecting a PC, data logger or RTU to one or more sensors with SDI-12 interface. The TBS06-TS connects to the RS232 interface and provides a SDI-12 compliant data interface. The TBS06-TS is a versatile tool for everyone who designs sensors and data recorders or who installs, tests or maintains SDI-12 based data acquisition systems. Furthermore it includes a SDI-12 bus sniffer mode. It is available in a IP67 housing from Fibox or in a Dinrail housing.
Features
RS232 toSDI-12 Interface
Transfer Mode / Monitor Mode
Plug and play
No driver required
Selectable data rate: 4800 - 38400 Baud
5V … 12V supply voltage
Low power mode
Spring loaded terminal blocks
IP67 housing or Dinrail housing
Operating Temperature Range:
- 40°C … + 85°C
Target Applications
SDI-12 Data Recording
SDI-12 Field Installations
SDI-12 Interface Debugging
SDI-12 Sensor Testing
Factory 4, F5, Lot I-3B-1 | Saigon Hi-Tech Park | Tan Phu Ward, District 9 | Ho Chi Minh City | Tel +84 (83)5471340
© 2021 Tekbox Digital Solutions
E-mail office@tekbox.com| www.tekbox.com
1
V1.0
TBS06-TS
RS232 to SDI-12 Interface
Contents
1 INTRODUCTION 3
1.1 P
1.2 M
2 APPLICATION 4
3 FUNCTIONAL DESCRIPTION 4
3.1 O
3.2 SDI-12 T
3.3 SDI-12 M
4 HARDWARE DESCRIPTION 5
4.1 B
4.2 C
4.3 C
5 SDI-12 BASICS 10
6 SETTING UP TBS06-TS 10
6.1 U
6.2 H
6.3 O
7 TRANSFER MODE 11
8 SDI-12 MONITOR MODE 12
RODUCT FEATURES
ECHANICAL DIMENSIONS
VERVIEW
OARD OVERVIEW ONNECTIONS – FIBOX VARIANT ONNECTIONS –
SER INTERFACE ARDWARE INTERFACE
PERATING MODES
4
RANSFER MODE
ONITOR MODE
3
3
4
5
5
DIN-
RAIL VARIANT
10
11
11
7
8
9 ORDERING INFORMATION 14
10 HISTORY 14
2
V1.0
TBS06-TS
RS232 to SDI-12 Interface
1 Introduction
SDI-12 is a standard for interfacing data recorders with microprocessor-based sensors. SDI-12 stands for serial/digital interface at 1200 baud. It can connect multiple sensors with a single data recorder on one cable. It supports up to 60 meter cable between a sensor and a data logger.
The SDI-12 standard is prepared by
SDI-12 Support Group (Technical Committee) 165 East 500 South River Heights, Utah 435-752-4200 435-752-1691 (FAX) http://www.sdi-12.org
The latest standard is version V1.3 and dates from July 18th, 2005. The standard is available on the web site of the SDI-12 Support Group.
TBS06-TS implements all functions for interfacing SDI-12 sensors to a RTU, data logger or PC with RS232 interface. It is a plug and play solution for controlling or testing of sensors with SDI-12 interface.
1.1 Product Features
RS232 to SDI-12 Interface based on TBS01 SDI-12 module  Transfer Mode  Plug and play  No driver required  Selectable data rate: 4800 - 38400 Baud  6V … 16V supply voltage  Current consumption: 6 mA in “always on mode”; less than 250µA in “auto power management
mode”
Fibox IP67 housing variant: Weidmueller spring loaded terminal blocks  Dinrail housing variant: screw terminal blocks  Operating Temperature Range: - 40°C … + 85°C
1.2 Mechanical dimensions
Fibox housing: Fibox PC 081206
http://www.fibox.com/catalog/1999/product/611/7032580_ENG3.html
Dinrail housing: Bud Industries DMB-4770
http://www.budind.com/pdf/hb4770.pdf
3
V1.0
TBS06-TS
RS232 to SDI-12 Interface
2 Application
RS232 to SDI-12 Converter
TBS06
Figure 1 –TBS06-TS Application, standard setup for controlling / testing sensors
3 Functional Description
3.1 Overview
The SDI-12 standard defines a set of commands to configure sensors and to initiate measurements. Upon receiving specific commands, the sensor may carry out internal tasks, respond with information on conversion time or send measurement data.
SDI-12 commands typically are ASCII strings generated by the data recorder/controller firmware. TBS06-TS can be controlled by a PC application or hyper terminal and converts the command strings to the logic levels and baud rate specified by the SDI-12 standard. Furthermore TBS06-TShandles breaks, marks and all other details of the SDI-12 protocol.
Upon receiving data or status information originated by a Sensor, TBS06-TS extracts the corresponding ASCII strings and sends it to COM Port of the PC.
3.2 SDI-12 Transfer mode
Hyper terminal or
customised PC
application
RS232 / SDI-12
Figure 2 – TBS06-TS basic application setup
The application is built based on a SDI-12 Recorder Protocol Stack Module. It receives commands from the RS232 Interface (e.g. via data logger, RTU or PC), and transfers the commands to the SDI Interface, waits for sensor response and transfers the response (measurement results, etc.) back to the RS232 Interface of the data logger, RTU or PC. All SDI-12 commands are supported.
4
Interface
Sensor(s)
V1.0
TBS06-TS
RS232 to SDI-12 Interface
3.3 SDI-12 Monitor mode
In SDI-12 monitor mode, TBS06-TS monitors the data traffic between recorder and sensor(s). This feature is useful in setting up or debugging SDI-12 installations. More details are available here.
Hyper terminal or
customised PC
application
Recorder
RS232 / SDI-12
Converter
Figure 3 –TBS06-TS application; setup for monitor mode
Sensor(s)
4 Hardware Description
4.1 Board overview
Figure 4 – Board Connections, Jumper Settings of Fibox variant
5
Loading...
+ 9 hidden pages