Input of cold water for electrical water heater is marked with blue ring, while hot water output
is marked with red ring, which is to be respected when connecting water heater to water
supply. Accumulation heater works under preassure (closed system) and it is possible to use
water at more than one point in the house.
The ttigns/mixing pipes appropriate for work under pressure have to be used with this water
heater.
On each accumulation water heater there have to be mounted a safety valve (see Picture 3)
to keep pressure in the tank from exceeding the limit. Such safety valve should be checked
every two weeks. By moving the lever or unscrewing the nut (depending on valve type)
exceeding water from return safety valve should come out meaning the valve is working
correctly. Non-return valve prevents tank to empty in case of pressure fall in water supply
pipeline. If regular water pressure in the pipeline is higher than 0,6 Mpa (6 bar) a reduction
valve has to be mounted on the cold water inlet connection.
CONNECTION TO WATER SUPPLY
1. Safety valve
2. Test valve
3. Non-return valve
4. Reduction valve
5. Interlocking valve
CW cold water
HW hot water
An interlocking must not come between the safety valve and the water heater, as it would
disable safety valve function. Fill the water heater with water before connecting it to electric
power supply. During the lling operation open the hot water pipe. When water starts coming
out the hot water pipe the water heater is full.If hot water is used on more than one spot in the
house it is recomandable to make internal pipeline as short as possible so that heat losses
are minimum.
The water heaters with heat exchanger are connected to water supply in the same way like
regular water heaters. Water heaters with heat exchanger are ment for connection to other
energy sources (centralized heating system, solar heating and heat punps). Entrance point
of heated media to the heat exchanger is marked with red, while exit
is marked with blue. Water heating with electrical heater and heat exchanger could function
contemporary or separately. Water heaters with heat exchanger are not designed for central
heating systems which uid temperature exceeds 110°C. Due water heating, water pressure
in water heater increas up to safety valve set limit, and water drops come out the valve. The
drip can be piped to the drain by installing a catching unit just below the
safety valve.In case the existing plumbing does not enable you to pipe the dripping water