INSTRUCTIONS FOR INSTALLATION, USE AND CARE OF WATER HEATERS
STANDARD MB 30, 50, 80 lit. STANDARD MB 80 H,
PRAKTIK MB 50, 80, 100, 120 lit. PRAKTIK MB 50, 80, 100, 120 lit. Inox
PRAKTIK MB PK 80,120 lit. PRAKTIK MB PK 80, 120 lit. Inox
SLIM MB 30, 50, 80 lit. SLIM MB 30, 50, 80 lit. Inox
Page 2
2
CONTENTS
Technical information.....................................................................3
Installation......................................................................................4
Connection to water supply............................................................8
Connection to power supply...........................................................9
Use, control and maintenace of electrical water heaters.............10
Waste disposal ............................................................................11
Page 3
3
pic.1
1. Housing
2. Polyurethane insulation
3. Heating tank (enamelled)
4. Screw, seal, nut, washer
5. Heater with seal
6. Flange
7. Flange sealing rubber
8. Counter-ange
9. Thermoregulator
10. Mg-anode
11. Connection tube for water
12. Rings
13. Connection tube for hot water output
14. Signal lamp
15. Thermoregulator button
16. Thermometer
17. Support for hanging to wall
18. Screws for support
TECHNICAL INFORMATION Electrical accumulation water heaters are designed to work with pressure of the water supply pipeline. The appliance is not meant for persons (including children) of reduced psychophysical abilities, unless under supervision of persons responsable for their safety, i.e. for persons not skilled for use of the appliance. Improper use of the appliance, especially from the side of children, should be prevented.
Water heaters are made according to valid standards and tested and certied by
authorized laboratory. Product technical characteristics are given on the sticker „Table with Characteristics“ between connection pipes.
Picture 1 shows design of the water heater with all parts
Page 4
4
INSTALLATION Only authorized persons are allowed to perform installation / connection of water
heaters to water and power supplies. All types of water heaters are xed to the
wall by 2 or 4 screws of 8 mm minimum diameter. Thin and delicate walls should be reinforced prior to water heater installation
Technical characteristics of accumulation water heater:
Model Standard MB 30 Standard MB 50 Standard MB 80
Capacity (litres) 30 50 80
Weight when full of
water (kg)
0.6 0.6 0.6
Weight when full of
water (kg)
17/47 22/72 29/109
Corrosion protection
type
Enamelled Mg
anode
Enamelled Mg
anode
Enamelled Mg
anode
Heater power (W) 2000 2000 2000
Voltage 230 230 230
Time of water
heating from 15°C
to 75°C
1
05
1
55
3
05
Model Praktik MB 80 Praktik MB 100 Praktik MB 120
Capacity (litres) 80 100 120
Weight when full of
water (kg)
0.6 0.6 0.6
Weight when full of
water (kg)
28/108 32/132 36/156
Corrosion protection
type
Enamelled Mg
anode
Enamelled Mg
anode
Enamelled Mg
anode
Heater power (W) 2000 2000 2000
Voltage 230 230 230
Time of water
heating from 15°C
to 75°C
2
55
3
50
4
35
Page 5
5
Model
Praktik MB
50 INOX
Praktik MB
80 INOX
Praktik MB
100 INOX
Praktik MB
120 INOX
Capacity (litres) 50 80 100 120
Weight when full of
water (kg)
0.6 0.6 0.6 0.6
Weight when full of
water (kg)
18/68 22/102 25/125 28/148
Corrosion protection
type
INOX
Mg anode
INOX
Mg anode
INOX
Mg anode
INOX
Mg anode
Heater power (W) 2000 2000 2000 2000
Voltage 230 230 230
Time of water
heating from 15°C
to 75°C
1
50
2
55
3
50
4
35
Model
Standart MB
80 H
Capacity (litres) 80
Weight when full of
water (kg)
0.6
Weight when full of
water (kg)
29/109
Corrosion protection
type
Enamelled
Mg anode
Heater power (W) 2000
Voltage 230
Time of water
heating from 15°C
to 75°C
3
20
The tank is insulated with quality polyurethane insulation providing that water stays hot
for long. Enamelled tanks are extra protected from corrosion by the magnesium anode.
Water from enamelled and stainless steel tanks is physiologically pure and therefore usable also for food preparation.
Model
KlassA MB 80
/ MB 80 SG
Capacity (litres) 80
Weight when full of
water (kg)
0.6
Weight when full of
water (kg)
29/109
Corrosion protection
type
Enamelled Mg
anode
Heater power (W) 2000
Voltage 230
Time of water
heating from 15°C
to 75°C
4
15
Page 6
6
G½" (G¾")

STANDARD MB 30
PRKTIK MB 50
PRKTIK MB 120
SLIM MB 80
STANDARD MB 50
PRKTIK MB 80
SLIM MB 30
MB STANDARD 80
PRKTIK MB 100
SLIM MB 50
A(mm) C(mm) E(mm) M(mm)
504
591
1091
1135
190
192
192
182
415 81
480 110
480 110
390 116
704
811
535
190
192
182
415 81
480 110
390 116
1004
951
785
190
192
182
415 81
480 110
390 116
B(mm) (mm) L(mm) N(mm)
293
384
884
953
395
454
454
354
100 130-360
100 130-360
600 130-360
730 240-300
493
604
303
395
454
354
300 130-360
320 130-360
130 240-300
793
744
603
395
454
354
600 130-360
460 130-360
380 240-300
KLASSA MB 50 SG
KLASSA MB 80
KLASSA MB 80 SG
KLASSA MB 50
604
860
219
219
480 110
480 110
860 219 480 110 640 219 480 110
395
615
454
454
100 130-360
100 130-360
615 454 320 130-360 395 454 100 130-360
Connection and installation measures:
Model PRAKTIK
Enameled water tank: MB PKL 80; MB PKD 80; MB PKL 120; MB PKD 120;
Stainless steel water tank: MB PKL 80 RFI; MB PKD 80 FI; MB PKL 120 FI; MB PKD 120 FI;
Heat exchanger
surface (m2)
0.25 0.3
Heat exchanger
connectors
G3/4” G1/2”
Heating uid
max. pressure (MPa)
0.6 0.6
Heating uid
max. temperature (°C)
90 90
Page 7
7
A (mm) B (mm) C (mm) Ф (mm) E (mm) L (mm)
STANDARD MB 80 H 1004 204 190 395 415 610
Left water heater MB 80 HL Right water heater MB 80 HD
Horisontal water heaters could be mounted as left or right depending on the position of the thermoregulator, and this models are designed to be mounted only on wall (not ceiling ) ,
so pipes are toward oor.
Page 8
8
Input of cold water for electrical water heater is marked with blue ring, while hot water output is marked with red ring, which is to be respected when connecting water heater to water supply. Accumulation heater works under preassure (closed system) and it is possible to use water at more than one point in the house.
The ttigns/mixing pipes appropriate for work under pressure have to be used with this water
heater. On each accumulation water heater there have to be mounted a safety valve (see Picture 3)
to keep pressure in the tank from exceeding the limit. Such safety valve should be checked
every two weeks. By moving the lever or unscrewing the nut (depending on valve type)
exceeding water from return safety valve should come out meaning the valve is working
correctly. Non-return valve prevents tank to empty in case of pressure fall in water supply pipeline. If regular water pressure in the pipeline is higher than 0,6 Mpa (6 bar) a reduction valve has to be mounted on the cold water inlet connection.
CONNECTION TO WATER SUPPLY
1. Safety valve
2. Test valve
3. Non-return valve
4. Reduction valve
5. Interlocking valve CW cold water HW hot water
An interlocking must not come between the safety valve and the water heater, as it would disable safety valve function. Fill the water heater with water before connecting it to electric
power supply. During the lling operation open the hot water pipe. When water starts coming
out the hot water pipe the water heater is full.If hot water is used on more than one spot in the house it is recomandable to make internal pipeline as short as possible so that heat losses are minimum.
The water heaters with heat exchanger are connected to water supply in the same way like regular water heaters. Water heaters with heat exchanger are ment for connection to other
energy sources (centralized heating system, solar heating and heat punps). Entrance point
of heated media to the heat exchanger is marked with red, while exit is marked with blue. Water heating with electrical heater and heat exchanger could function contemporary or separately. Water heaters with heat exchanger are not designed for central heating systems which uid temperature exceeds 110°C. Due water heating, water pressure
in water heater increas up to safety valve set limit, and water drops come out the valve. The drip can be piped to the drain by installing a catching unit just below the
safety valve.In case the existing plumbing does not enable you to pipe the dripping water
Page 9
9
from the return safety valve into the drain, you can avoid the dripping by installing a 3-litre
expansion tank on the inlet water pipe of the boiler. Water may come out in drops from the exhaust pipe of pressure reduction device i.e, safety
valve, this pipe has to be open and positioned downwise, to prevent freezing of the water in the pipe. By regular function of the safety valve it should be possible to remove limescale sediment as well as to check if it is bloacked. Safety valve is delivered with the water heater and the sheme shows how to install it. At installation of a water heater and its connection to water supply, it is recomanded to use new set of hoses, old ones should not be used. CONNECTION TO POVER SUPPLY Electric accumulation water heater is connected to power supply by valid standards for
electrical installations, with a plug cable 3x1,5 mm H05VV.
Before connecting power supply cable, unscrew the two screws and remove protection cap of the electric water heater. The electric water heater is not delivered with a device to cut off the power from the supply permanently. A separating element of all the poles from the supply should be included, according to local installation rules. Such separating means have to be included in the electrical installation.
1. Thermoregulator
2. Heater
3. Connection clamp
4. Signal lamp L – phase N neutral Ground
WARNING: Before any intervention the water heater must be disconnected
from the power supply line.
USE, CONTROL, MAINTENANCE OF ELECTRIC WATER HEATERS
After connecting it to water and power supplies the water heater is ready to use. For types
without external heater regulation (no button on the cover), water temperature is regulated
by a preset thermoregulator. It is recomanded not to change the set temperature (t=55°C) being optimal for saving energy and minimum limestone sedimentation. Should the user
however want to change the temperature of water heating, the water heater should rst be
disconnected from power supply line, protection cap on the bottom should be taken off, and by turning plastic button directly on the thermoregulator, water heating temperature can be set to be lower or higher within the range 20 to 70±5°C.
Page 10
10
For water heater types with external regulation, by simple turning the button desired
water heating temperature can be set within the range 20 to 70±5°C. When desired/ set temperature is reached inside the the tank the thermoregulator will cut the power circuit automatically, and the signal lamp which has been on during the heating time, will go off.
WARNING: before using hot water from water heater turn it off from elecrical power
supply.
Water heaters also have thermometers with metal cap and bimetal showing the temperature of the water. If water heater will not be used for longer period it is recomanded to disconnect it from power supply line. If water inside the water heater could freeze while not used it is recomanded to empty the tank. The miantenance tips should be respected, especially check-up for how much Mg anode is consumed, at least every 36 months, and replace it if needed. The limestone sediment should be removed regularly. For such interventions tank must be emptied. To empty the tank please proceed as follows:
- Disconnect the water heater from power supply
- Close the inlet cold water valve
- Open the hot water pipe
- Unscrew the safety valve mounted on the cold water inlet, and wait for water to go out.
After that the unscrew the nut of the heater counterange, take out the ange with the heater,
remove the limescale and replace Mganode. If you use chemical products for limescale removal, they must not come into contact with Mg-anode (anode should be taken out).
Afterwards the tank should be rinsed and relled with water.
WASTE DISPOSAL – WHAT AFTER YOUR WATER HEATER IS NO MORE USABLE
The accumulation water heaters and the packing are made of recyclable materials. After your water heater is not usable any more, it is forbidden to dispose it as non-selected waste. For waste disposal, the water heater
plactic and rubber parts should be separated from metal parts, classied
and left for recycling or
nal disposal according to loacal regulations.Only by waste separation and
management you will protect the environment.