Tecumseh VSC5550BNA Performance Data Sheet

Performance Data Sheet
VSC5550BNA
General Information
Model VSC5550BNA Refrigerant R-410A Test Condition ARI Performance Test Voltage 230V ~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 16000 14300 Watts 2620 3070 Amps 17.5 19.0
Lb/h 193 182
Btu/h 18500 16700 15100 Watts 2600 3050 3550 Amps 17.5 19.0 20.7
Lb/h 222 211 200
Btu/h 21300 19500 17700 15900 Watts 2590 3020 3510 4070 Amps 17.5 19.0 20.6 22.6
Lb/h 254 244 233 221
Btu/h 24400 22500 20700 18800 16700 Watts 2580 3000 3480 4030 4650 Amps 17.6 19.0 20.6 22.5 24.8
Lb/h 289 280 270 259 244
Btu/h 28000 25900 23900 21900 19700 Watts 2570 2980 3450 3990 4610 Amps 17.6 19.0 20.6 22.5 24.7
Lb/h 328 319 310 300 286
Btu/h 31800 29700 27500 25300 23000 20500 17800 Watts 2560 2960 3430 3960 4570 5260 6040 Amps 17.5 19.0 20.6 22.4 24.6 27.2 30.4
Lb/h 372 363 354 344 332 315 294
Btu/h 36100 33800 31500 29100 26600 24000 21000 Watts 2550 2950 3400 3930 4530 5210 5990 Amps 17.5 18.9 20.5 22.4 24.5 27.1 30.2
Lb/h 419 410 402 392 380 365 344
Btu/h 40800 38200 35700 33200 30500 27700 24500 Watts 2550 2930 3380 3900 4490 5170 5940 Amps 17.5 18.9 20.5 22.3 24.5 27.0 30.1
Lb/h 470 462 454 445 433 418 399
Btu/h 45800 43100 40400 37600 34700 31700 28300
25
30
35
40
45
50
55
Watts 2540 2920 3360 3870 4460 5130 5890 Amps 17.4 18.8 20.4 22.2 24.4 26.9 30.0
Lb/h 526 518 510 501 490 476 457
Btu/h 51300 48400 45400 42400 39300 36000 32400 Watts 2530 2900 3330 3840 4420 5090 5850 Amps 17.3 18.8 20.4 22.2 24.3 26.8 29.8
Lb/h 586 578 570 561 551 537 519
Btu/h 57300 54100 50900 47600 44200 40600 36800 Watts 2520 2880 3310 3800 4380 5040 5800 Amps 17.2 18.7 20.3 22.1 24.2 26.7 29.7
Lb/h 651 642 634 626 616 602 585
Btu/h 63700 60200 56700 53200 49500 45600 41500 Watts 2510 2860 3280 3770 4340 5000 5750 Amps 17.1 18.5 20.2 22.0 24.1 26.6 29.6
Lb/h 720 711 703 695 685 672 655
Btu/h 70500 66800 63000 59200 55200 51000 46600 Watts 2490 2840 3250 3730 4300 4950 5700 Amps 16.9 18.4 20.0 21.9 24.0 26.5 29.5
Lb/h 794 785 777 768 758 746 729
Btu/h 77900 73800 69700 65600 61300 56800 52000 Watts 2470 2810 3210 3690 4250 4900 5650 Amps 16.7 18.2 19.9 21.7 23.9 26.4 29.3
Lb/h 873 863 855 847 837 824 808
Btu/h 85700 81300 76900 72400 67800 62900 57800 Watts 2440 2780 3180 3650 4210 4850 5590 Amps 16.4 18.0 19.7 21.6 23.7 26.2 29.2
Lb/h 957 947 938 929 919 907 891
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 4.862806E+04 5.645805E+02 3.168688E+00 4.950936E+02 C2 8.204494E+02 1.825729E+01 -3.092754E-02 7.786380E+00 C3 -4.821694E+02 1.824912E+01 3.108777E-01 -5.502787E+00 C4 1.049182E+01 4.319922E-03 -9.667687E-04 9.015611E-02 C5 -1.647312E+00 -3.109888E-01 1.012817E-03 -1.526085E-02 C6 3.135749E+00 -4.102972E-03 -2.736433E-03 5.286174E-02 C7 1.924814E-02 -9.133500E-04 -3.526248E-06 1.627138E-04 C8 -4.255387E-02 5.034446E-04 9.489981E-06 -1.788442E-04 C9 -3.449791E-03 7.049802E-04 -7.542346E-06 1.421786E-04
C10 -1.109989E-02 1.132404E-03 1.372164E-05 -2.034239E-04
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature