Performance Data Sheet
VSC5525ENA
General Information
Model VSC5525ENA Refrigerant R-22
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 8130 7380
Watts 1280 1410
Amps 7.08 7.31
Lb/h 104 99.2
Btu/h 9410 8640 7830
Watts 1300 1430 1570
Amps 7.28 7.58 7.85
Lb/h 120 115 110
Btu/h 10800 9990 9160 8280
Watts 1300 1440 1590 1740
Amps 7.42 7.77 8.10 8.53
Lb/h 137 132 127 121
Btu/h 12300 11400 10600 9670 8700
Watts 1310 1450 1600 1760 1930
Amps 7.51 7.91 8.30 8.78 9.47
Lb/h 155 151 145 139 132
Btu/h 13900 13000 12100 11200 10200
Watts 1310 1460 1610 1780 1960
Amps 7.56 8.00 8.43 8.97 9.71
Lb/h 174 170 165 159 152
Btu/h 15600 14700 13700 12700 11700 10600 9410
Watts 1310 1460 1620 1790 1980 2170 2350
Amps 7.57 8.05 8.53 9.10 9.89 11.0 12.6
Lb/h 195 191 186 180 173 165 156
Btu/h 17400 16500 15500 14400 13300 12200 11000
Watts 1310 1460 1620 1800 1990 2190 2390
Amps 7.55 8.07 8.58 9.19 10.0 11.2 12.8
Lb/h 217 213 208 202 195 188 179
Btu/h 19400 18400 17400 16300 15100 13900 12600
Watts 1310 1460 1620 1810 2000 2210 2420
Amps 7.52 8.06 8.60 9.24 10.1 11.3 12.9
Lb/h 240 236 231 226 219 212 203
Btu/h 21600 20500 19400 18200 17000 15700 14400
25
30
35
40
45
50
55
Watts 1310 1450 1620 1810 2010 2220 2440
Amps 7.47 8.03 8.60 9.27 10.2 11.4 13.1
Lb/h 265 261 256 251 245 238 229
Btu/h 23900 22700 21500 20300 19000 17700 16300
Watts 1310 1450 1620 1810 2010 2230 2460
Amps 7.43 8.00 8.58 9.27 10.2 11.4 13.1
Lb/h 291 287 283 278 272 265 257
Btu/h 26300 25100 23900 22600 21200 19800 18300
Watts 1310 1450 1620 1810 2010 2240 2470
Amps 7.39 7.97 8.56 9.27 10.2 11.5 13.2
Lb/h 319 316 312 307 301 294 286
Btu/h 29000 27700 26300 25000 23500 22000 20400
Watts 1310 1450 1610 1800 2010 2240 2480
Amps 7.37 7.95 8.55 9.26 10.2 11.5 13.2
Lb/h 349 346 342 337 332 325 318
Btu/h 31800 30400 29000 27500 26000 24400 22700
Watts 1320 1450 1610 1800 2010 2240 2480
Amps 7.37 7.95 8.54 9.26 10.2 11.5 13.2
Lb/h 381 378 374 370 365 358 351
Btu/h 34900 33400 31800 30300 28600 27000 25200
Watts 1330 1450 1610 1800 2010 2240 2490
Amps 7.40 7.97 8.56 9.27 10.2 11.5 13.3
Lb/h 414 412 408 404 399 393 386
Btu/h 38100 36500 34900 33200 31500 29700 27800
Watts 1340 1460 1610 1800 2010 2240 2490
Amps 7.48 8.03 8.60 9.30 10.2 11.5 13.3
Lb/h 450 448 445 441 436 430 424
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.839688E+04 1.101489E+03 -9.512046E+00 1.709635E+02
C2 3.617763E+02 9.325122E+00 -4.091385E-02 3.546790E+00
C3 -8.060743E+01 -1.232786E+01 4.992558E-01 -6.863285E-02
C4 3.326288E+00 1.061476E-01 1.095251E-04 2.181127E-02
C5 -6.889767E-01 -2.653659E-01 4.336169E-04 1.242823E-03
C6 1.534015E-01 2.389611E-01 -5.057392E-03 -5.060039E-04
C7 1.217846E-02 9.724992E-04 1.121991E-05 1.266438E-04
C8 -1.305797E-02 -2.031271E-03 -1.222188E-05 1.389469E-05
C9 8.383898E-05 1.978343E-03 3.029698E-06 1.146078E-05
C10 -1.289413E-03 -6.550461E-04 1.845803E-05 -1.370911E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature