Tecumseh VSAG529ZXTXM Performance Data Sheet

F
7
TECUMSEH HERMETIC
CONDENSING UNIT
Model VSAG529ZXTXM BOM 32T7242-2
Air Cooled 7 ¼ HP Application Low Temp
VSAG529ZXTXM
TPC___preliminary
October 14, 2011
Refrigerant R404A
45.01
28.50
17.50
LIQUID 1/2"
Dimensions (inch)* Line connections
VS AG 52 9Z X TX M
*) Mo un ting H o les, 17.5 0 x 39 .94 Factory charge 20 psig dry air,
Evaporator
T, °
PSIGBTUH Watts Head Cond T BTUH Watts Head Cond T BTUH WattsHead Cond T BTUH Watts Head Cond T
-40 5.5 142 00 4550 202 90 1300 0 5000 234 99 1240 0 5570 269 109 109 00 624 0 307 119
-35 8.0 16200 4700 207 91 14700 5130 238 101 13900 5690 273 110 12200 6330 310 120
-30 10.7 18500 4850 212 9 3 16800 5270 242 102 15700 5810 277 111 138 00 644 0 313 120
-25 14.0 21000 5010 216 9 4 19000 5420 247 103 17700 5950 281 112 156 00 657 0 317 121
-20 17.1 23700 5180 222 9 6 21400 5590 252 105 19900 6110 286 114 177 00 671 0 321 122
-15 19.3 26600 5370 227 9 7 24100 5770 257 106 22300 6280 291 115 199 00 687 0 326 124
-10 24.5 29600 5570 233 9 9 26800 5960 262 108 24900 6470 296 116 222 00 705 0 331 125
-5 28.8 32800 5780 238 101 29 70 0 6170 2 68 109 27600 6680 302 118 247 00 725 0 337 126 0 33.5 36100 6010 245 103 32800 6410 274 111 30400 6910 308 119 27300 7470 343 127 5 36.5 39400 6260 251 104 35900 6660 281 112 33200 7160 315 121 30000 7720 350 129
10 43 .
Pe rforma nc e @ 6 0 H z , Re turn ga s 4 0
42900 6530257 106 39000 6930 288 114 36100 7430322 122 32700 7990 357 130
LWH
28.50 44.97 26.78
MUST BE EVACUATED
80°F 90°F 100°F 110°F
39.94
41.78
o
F, SubCooling 5oF
SUCTION 7/8"
Suction
7/8 Sweat 1/2 Sweat
Ambient Temperatures
26.78
Pumpdown Air flow Oil Ch.
90% @ 90
37.69
o
F
SCFMLiquid
4200
Oz.
24
Gross weight
Lbs.
400
PRELIMINARY PERFORMANCE DATA
V
VSAG529ZXTXM
TPC___preliminary October 14, 2011
Parts/Specifications
Unit BOM 32T7242-2 Unit MODEL
SAG529Z XTXM
Fan Motor 810S186B40 Fan Motor Qty 2
Fan Motor RLA 1.9 Refrigeration RANGE -40°F to 10°F Fan Blade 51528-3 Design Pressure Low 181 Fan Guard 70832 Design Pressure High 450 Shroud 70611-1 Volts - HZ - Ph 200-230V 3~ 60HZ Voltage Range 180 - 253 High Pressure switch 84095-2 Min. Circuit Ampacity 26.16 Low Pressure Control 84026-2 Max. Fuse Size 45 Dual Pressure Conrol
Compressor MODEL VSAG523ZXT Condenser 50777-6 Compressor BOM VS120RT-006-A4 Head Master Valve Compressor LRA 156.1 Check Valve Compressor RLA 17.88 Process Valve
Li quid Valve OverLoad INTERNAL Suction Valve 31529-2 Relay Run Capacitor Receiver 51084 Run Capacitor Rating Receiver Qty 1 Start Capacitor Accumulator TK00044000 Start Capacit or Rating Li quid Fi lter 52000-164D Contactor 91014B Sight Glas s 70084-2
Suction Filter 70822-5S Unit Drawing DGU1950-14 Wiring Diagram WD23-2FL CrankCase Heater
IMPORTANT:
COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.)
SOLENOID
POWER SUPPLY
208-230 / 60 / 3
COMPRESSOR
TERMINAL
LIQUID INJE C T IO N
COMPRESSOR
CONTACTOR COIL
L3 L2 L1
GRD
C
S R
see note A
T3 T2 T1
COMPRESSOR CONTACTOR
NO AUXILIARY SWITCH
HP DT LP
RECEIVER
HEATER
THERMOSTAT
CRANK CASE
HEATER
BLACK
RED
YELLOW
COMPRESSOR
CONTACTOR
TERMINAL
BOARD
NOTES
FIELD WIRING NOTES
1. ALL FIEL D W IRING MUST BE D ONE IN COMPLIA N C E WITH ALL APPLICABLE LOCAL AND NATIONAL CODES.
2. CONNECT INCOMING POWER LEADS FROM PO W E R SUPPLY TO L1, L2, A ND L3 IN COMPR E SSOR CONTAC T O R OR TO L1, L2 AND L 3 IN DISCONN ECT SWITCH (IF P R OVIDED). USE CO OPER CONDUC T O R S ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER S EULEME NT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C ( M IN .) WIRING
3. IF REQUIRED INSTALL SYSTEM REMOTE CONTROL BETW EEN P1 AND P2
FAN 1
FAN 2
FFC2
FFC1
P3
P1
P2
L1
L2 L3
T1
T3T2
IN TERMIN AL BLOCK AND R E MOVE THE JUMP E R
GENERAL NOTES:
A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET.
FFC1 (FFC2)
FAN CONTROL 1 (2)
LP
LOW PRESSURE CONTROL
HP
HIGH PRESSURE SWITCH
DT
DISCHARGE LINE THERMOSTAT
FACTORY COMPONENTS
OPTIONAL FACTORY COMPONENTS
OPTIONAL FIELD COMPONENTS
CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control,
REL
REVISION
WD23-2FL
DEC 21, 2010
Loading...