Performance Data Sheet
TPA0415YXC
General Information
Model TPA0415YXC Refrigerant R-134a
Test Condition ARI Performance Test Voltage 240V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type RSIR
Performance Information
Evap Temp (°F)
20
25
30
35
40
45
50
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 1760 1650 1540 1430 1320 1200 1090
Watts 214 225 235 245 256 266 276
Amps 1.95 1.96 1.98 2.00 2.02 2.04 2.06
Lb/h 23.2 22.7 22.1 21.5 20.9 20.3 19.7
Btu/h 2000 1870 1740 1610 1490 1360 1230
Watts 221 233 244 256 268 279 291
Amps 1.95 1.97 2.00 2.02 2.04 2.06 2.09
Lb/h 26.3 25.6 25.0 24.3 23.6 22.9 22.2
Btu/h 2260 2110 1960 1820 1670 1520 1380
Watts 228 240 253 266 279 292 305
Amps 1.96 1.98 2.01 2.04 2.06 2.09 2.12
Lb/h 29.7 28.9 28.2 27.4 26.6 25.8 25.0
Btu/h 2540 2370 2200 2030 1870 1700 1540
Watts 235 248 262 276 290 304 318
Amps 1.97 2.00 2.03 2.06 2.09 2.12 2.15
Lb/h 33.6 32.7 31.8 30.9 30.0 29.1 28.2
Btu/h 2850 2660 2470 2280 2090 1900 1720
Watts 242 256 271 286 301 316 331
Amps 1.99 2.02 2.05 2.08 2.12 2.15 2.19
Lb/h 37.8 36.8 35.7 34.7 33.7 32.7 31.7
Btu/h 3200 2970 2760 2540 2330 2120 1920
Watts 251 265 280 296 311 327 344
Amps 2.01 2.04 2.08 2.11 2.15 2.19 2.22
Lb/h 42.5 41.3 40.1 39.0 37.8 36.7 35.6
Btu/h 3570 3320 3070 2830 2600 2370 2140
Watts 260 275 290 306 322 339 356
Amps 2.04 2.07 2.11 2.15 2.18 2.22 2.27
Lb/h 47.7 46.3 45.0 43.7 42.4 41.1 39.9
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.246609E+03 1.366604E+02 1.926824E+00 1.565089E+01
C2 6.134077E+01 -2.142246E-01 -7.414524E-03 4.504431E-01

C3 -3.023136E+00 6.009070E-01 3.712056E-04 -1.146465E-02
C4 4.160335E-01 -2.590466E-03 5.915278E-05 7.627772E-03
C5 -3.983136E-01 2.186139E-02 7.272747E-05 -2.245454E-03
C6 -1.022833E-03 -1.743923E-04 -1.026371E-06 5.656650E-06
C7 3.613106E-03 3.601281E-04 1.022092E-06 2.373202E-05
C8 -3.297447E-03 -3.272954E-04 -9.042250E-07 -2.228266E-05
C9 9.429019E-04 9.324908E-05 2.508025E-07 6.545298E-06
C10 -7.521174E-05 -6.834528E-06 -1.343985E-08 -6.367017E-07
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature

Performance Data Sheet
TPA0415YXC
General Information
Model TPA0415YXC Refrigerant R-134a
Test Condition ARI Performance Test Voltage 240V ~ 50HZ
Return Gas 4.4°C (40°F) RETURN GAS Motor Type RSIR
Performance Information
Evap Temp (°F)
0
5
10
15
20
25
30
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 1020 946 874 803 731 660 590
Watts 193 198 203 208 213 218 223
Amps 1.89 1.89 1.90 1.91 1.91 1.92 1.92
Lb/h 14.3 13.8 13.4 12.9 12.5 12.0 11.5
Btu/h 1180 1100 1010 933 852 772 692
Watts 200 206 213 219 225 231 237
Amps 1.90 1.91 1.92 1.93 1.94 1.95 1.96
Lb/h 16.4 15.9 15.4 15.0 14.5 14.0 13.6
Btu/h 1340 1250 1160 1070 976 886 796
Watts 207 215 222 229 237 244 251
Amps 1.90 1.92 1.93 1.95 1.96 1.97 1.99
Lb/h 18.7 18.2 17.7 17.2 16.7 16.2 15.7
Btu/h 1520 1420 1310 1210 1110 1010 905
Watts 214 223 231 240 248 257 266
Amps 1.91 1.93 1.95 1.96 1.98 2.00 2.02
Lb/h 21.2 20.7 20.1 19.6 19.0 18.5 18.0
Btu/h 1720 1600 1480 1360 1250 1140 1020
Watts 221 231 240 250 260 270 280
Amps 1.92 1.94 1.96 1.98 2.00 2.02 2.04
Lb/h 24.0 23.4 22.8 22.2 21.6 21.0 20.5
Btu/h 1930 1790 1660 1530 1410 1280 1150
Watts 227 238 250 261 272 283 294
Amps 1.93 1.95 1.97 2.00 2.02 2.04 2.07
Lb/h 27.1 26.4 25.8 25.1 24.4 23.8 23.2
Btu/h 2160 2010 1870 1720 1580 1440 1300
Watts 234 246 259 271 283 295 308
Amps 1.94 1.97 1.99 2.02 2.04 2.07 2.10
Lb/h 30.5 29.8 29.0 28.3 27.6 26.9 26.2
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.590179E+03 1.538137E+02 1.841906E+00 1.792590E+01
C2 4.822482E+01 -5.792528E-01 -4.168903E-03 4.547616E-01

C3 -7.111999E+00 4.931860E-01 5.981773E-04 -4.511403E-02
C4 2.292420E-01 -1.343129E-03 -5.084677E-06 4.453728E-03
C5 -2.250242E-01 2.463623E-02 7.208131E-05 -7.234982E-04
C6 -1.141329E-03 4.247585E-05 -2.415499E-07 -1.083941E-05
C7 4.682101E-03 6.250728E-05 2.054709E-06 5.518001E-05
C8 -1.870301E-03 -2.515554E-05 -8.016709E-07 -2.200642E-05
C9 1.903401E-04 2.575405E-06 7.895273E-08 2.234340E-06
C10 6.401015E-06 -3.741901E-07 8.750842E-10 5.493114E-08
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature