Tecumseh THG1358YLS User Manual

Performance Data Sheet
THG1358YLS
General Information
Model THG1358YLS Refrigerant R-134a Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ Return Gas 32.2°C (90°F) RETURN GAS Motor Type PTCS_IR
Performance Information
Temp (°C)
-40
-35
-30
-25
-23.3
-20
-15
-10
Condensing Temperature (°C)
30 40 50 60
Btu/h 204 163 125 91.4
Watts (Power) 68.8 68.6 67.4 64.6
Amps 1.17 1.19 1.20 1.19
Lb/h 1.87 1.35 0.86 0.43
Btu/h 381 334 286 241
Watts (Power) 91.0 90.8 89.6 86.7
Amps 1.25 1.26 1.26 1.25
Lb/h 4.18 3.58 2.98 2.42
Btu/h 534 481 425 369
Watts (Power) 108 108 108 107
Amps 1.32 1.32 1.32 1.31
Lb/h 6.14 5.49 4.81 4.12
Btu/h 688 631 569 504
Watts (Power) 121 124 127 127
Amps 1.37 1.38 1.39 1.39
Lb/h 8.13 7.43 6.67 5.87
Btu/h 746 688 624 556
Watts (Power) 125 130 133 135
Amps 1.39 1.40 1.41 1.42
Lb/h 8.86 8.16 7.37 6.54
Btu/h 871 811 744 671
Watts (Power) 134 141 147 151
Amps 1.43 1.45 1.47 1.49
Lb/h 10.5 9.74 8.92 8.03
Btu/h 1110 1050 977 898
Watts (Power) 149 160 171 181
Amps 1.50 1.54 1.58 1.63
Lb/h 13.5 12.8 11.9 10.9
Btu/h 1430 1370 1290 1210
Watts (Power) 168 186 203 218
Amps 1.59 1.66 1.74 1.82
Lb/h 17.6 16.9 16.0 14.9
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.456449E+03 1.318488E+02 1.621872E+00 3.072508E+01 C2 1.225449E+02 2.974061E+00 1.429997E-02 1.583381E+00 C3 2.500042E+00 3.121136E+00 2.878876E-03 3.524332E-02 C4 3.148680E+00 1.734562E-01 6.779671E-04 4.085018E-02 C5 2.527519E-01 1.809483E-01 7.985799E-04 2.912545E-03 C6 -1.371354E-01 9.467872E-03 2.498739E-04 -1.799635E-03 C7 3.556932E-02 3.449843E-03 1.501856E-05 4.604213E-04 C8 2.879247E-03 2.465504E-03 1.627100E-05 2.805558E-05 C9 -2.508429E-03 3.410864E-05 2.727054E-06 -3.201573E-05
C10 4.074326E-04 -1.107016E-04 -1.410378E-06 5.522982E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature