Tecumseh THA0412YXASK User Manual

8.80
8.93
0.50
Ø0.38
L W H
Ambient Temperatures
80°F 90°F 100°F 110°F
T, °F PSIG BTUH Watts Head Cond T BTUH Watts Head Cond T BTUH Watts Head Cond T BTUH Watts Head Cond T
-10 23.9 710 190 102 88 660 190 120 98 600 190 141 107 550 190 164 117
-5 28.2 810 200 104 90 750 200 123 99 690 210 144 109 630 210 167 118 0 32.8 930 210 107 91 860 220 126 101 790 220 147 110 720 220 170 120 5 37.9 1070 230 110 93 990 230 129 102 910 230 151 112 830 240 174 121
10 42.4 1220 240 114 95 1130 250 133 104 1050 250 155 113 960 260 179 123 15 48.2 1390 260 118 97 1290 260 137 106 1200 270 159 115 1100 270 183 125
20 54.5 1580 270 122 99 1470 280 142 108 1360 290 164 117 1250 290 189 126
25 61.2 1770 290 127 101 1650 290 147 110 1530 300 170 119 1410 310 194 128 30 68.4 1970 300 132 103 1840 310 152 112 1710 320 175 121 1580 330 201 131 35 76.1 2180 320 137 106 2030 330 158 115 1890 340 182 124 1750 350 207 133
40 84.4 2380 330 143 108 2220 350 164 117 2070 360 188 126 1910 370 214 135
Line Connections
Dimensions, inches (mm)
Gross weight
Lbs. (kg)
Pumpdown
AirFlow
Oil Ch.
Oz.
CFM
90% @90oF
190
8.2 Model
16.0
(406)
11.5
(292)
8.9
(226)
THA0412YXASK
THA0412YXASS
Suction
Liquid
Factory charge 20 PSIG dry air, MUST BE EVACUATED
Evaporator
Performance @ 60 Hz, Return gas 40oF below 20oF Evaporator and 65oF above 20oF evaporator, SubCooling 5oF
3/8" Valve Sweat
1/4" Valve Sweat
5/16" Sweat
1/4" Sweat
n/a
38.1 (17.3)
39.5 (13.4)
CELSEON® LOW PROFILE
CONDENSING UNIT
Model THA0412YXASK, -SS BOM 32G572-39S, -69S
Air Cooled 1/5 HP Application Commercial Temp Refrigerant R134a Volts-Hz-Ph 115/60/1
THA0412YXAS(x)_REV1
TPC - November 3, 2014
Unit BOM 32G572-39S Condenser 506-G333
Unit MODEL THA0412YXASK Fan Guard 116-002P
Condenser, Fan Guard Kit K135-01 Refrigerant R134a Power Cord 85106-10 Refrigeration RANGE -10°F to 45°F Design Pressure Low 150 Fan Motor 810L006B94 Design Pressure High 300 Fan Motor RLA 0.41 Volts - HZ - Ph 115/60/1 Fan Blade 4VEA009 Voltage Range 103.5 - 126.5 Replacement Fan Motor 6W115 Min. Circuit Ampacity 4.6 Max. Fuse Size 15
Compressor MODEL THA0412YXA
Compressor BOM TH760AR-340-J7
Compressor LRA 27.5 Unit BOM
Compressor RLA 3.35
Unit MODEL
Liquid Receiver OverLoad T5706-24-ZP Replacement Kit - O/L
Unit BOM
Relay RP5815-ZR
Unit MODEL
Replacement Kit - Relay K71-70 Liquid Receiver Run Capacitor Liquid Valve Replacement Kit - Run Cap. Suction Valve Start Capacitor Replacement Kit - St. Cap.
Unit BOM 32G572-69S
Unit MODEL THA0412YXASS
Unit drawing DGU DGU1896-G806 Liquid Valve 56605 Electrical Diagram DETH4 Suction Valve 56604
Parts/Specifications
THA0412YXAS(x)_REV1
TPC - November 3, 2014
Loading...