Performance Data Sheet
RNA5526CXN
General Information
Model RNA5526CXN Refrigerant R-407C
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 7690 7700
Watts 1390 1430
Amps 6.38 6.74
Lb/h 88.9 97.8
Btu/h 8710 8510 8510
Watts 1420 1480 1530
Amps 6.57 6.90 7.39
Lb/h 103 107 117
Btu/h 9960 9550 9320 9280
Watts 1450 1520 1580 1650
Amps 6.76 7.07 7.52 8.14
Lb/h 119 121 126 137
Btu/h 11400 10800 10400 10100 9950
Watts 1480 1560 1640 1720 1810
Amps 6.94 7.24 7.66 8.24 9.00
Lb/h 139 137 140 146 156
Btu/h 13100 12300 11700 11200 10800
Watts 1500 1590 1690 1780 1890
Amps 7.10 7.41 7.82 8.38 9.10
Lb/h 161 157 157 159 166
Btu/h 15000 14000 13200 12500 11800 11300 10800
Watts 1520 1630 1740 1840 1960 2090 2250
Amps 7.24 7.57 7.99 8.53 9.22 10.1 11.1
Lb/h 186 180 177 177 180 185 193
Btu/h 17000 16000 14900 14000 13100 12300 11600
Watts 1540 1660 1780 1900 2030 2180 2340
Amps 7.35 7.71 8.15 8.69 9.37 10.2 11.2
Lb/h 213 206 201 199 199 200 204
Btu/h 19300 18000 16900 15700 14600 13600 12600
Watts 1550 1690 1820 1950 2100 2250 2430
Amps 7.41 7.82 8.30 8.86 9.54 10.4 11.3
Lb/h 242 234 228 224 222 221 221
Btu/h 21600 20300 19000 17700 16400 15100 13900
25
30
35
40
45
50
55
Watts 1550 1710 1850 2000 2160 2330 2510
Amps 7.43 7.91 8.43 9.02 9.71 10.5 11.5
Lb/h 272 265 259 253 249 246 243
Btu/h 24200 22700 21300 19800 18300 16800 15300
Watts 1550 1720 1880 2040 2210 2390 2590
Amps 7.40 7.96 8.54 9.17 9.89 10.7 11.7
Lb/h 305 298 292 286 281 276 271
Btu/h 26800 25300 23700 22100 20500 18800 17100
Watts 1540 1730 1900 2080 2260 2450 2670
Amps 7.31 7.95 8.61 9.31 10.1 10.9 11.9
Lb/h 339 333 327 321 316 310 303
Btu/h 29600 28000 26300 24600 22800 20900 19000
Watts 1520 1720 1920 2110 2300 2510 2730
Amps 7.15 7.90 8.64 9.41 10.2 11.1 12.1
Lb/h 374 369 365 360 354 348 340
Btu/h 32500 30800 29100 27200 25300 23200 21100
Watts 1490 1710 1920 2130 2340 2560 2790
Amps 6.91 7.78 8.63 9.49 10.4 11.3 12.4
Lb/h 410 408 405 401 396 390 382
Btu/h 35500 33800 31900 30000 27900 25700 23400
Watts 1460 1690 1920 2140 2360 2590 2840
Amps 6.59 7.59 8.56 9.52 10.5 11.5 12.6
Lb/h 446 447 447 445 441 435 428
Btu/h 38600 36800 34900 32900 30700 28300 25900
Watts 1410 1660 1900 2140 2380 2620 2880
Amps 6.18 7.33 8.43 9.50 10.6 11.7 12.8
Lb/h 484 488 491 491 489 484 477
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.142218E+04 -5.086540E+01 5.976646E+00 3.196456E+02
C2 4.090947E+02 -2.383671E+01 -8.383837E-02 4.447773E+00
C3 -1.792605E+02 3.682786E+01 2.765415E-02 -4.318797E+00
C4 1.777575E+00 -9.785645E-02 -2.595701E-03 -3.989966E-02
C5 1.065921E+00 4.287115E-01 2.792762E-03 4.091591E-02
C6 6.464699E-01 -3.101869E-01 -5.459430E-04 2.795432E-02
C7 -1.636442E-02 -1.050139E-03 -9.860418E-06 -2.803647E-04
C8 2.937384E-02 5.435816E-04 2.827072E-05 1.163983E-03
C9 -2.793613E-02 -8.578174E-04 -1.643783E-05 -5.517976E-04
C10 4.252080E-04 1.105922E-03 4.380787E-06 -2.771168E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature