Performance Data Sheet
RNA5518YNA
General Information
Model RNA5518YNA Refrigerant R-134a
Test Condition ARI Performance Test Voltage 230V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 5510 5350
Watts 865 905
Amps 3.73 4.04
Lb/h 69.6 71.3
Btu/h 6240 6020 5840
Watts 887 941 975
Amps 3.91 4.23 4.50
Lb/h 79.5 80.7 82.6
Btu/h 7070 6790 6540 6320
Watts 907 974 1020 1050
Amps 4.06 4.40 4.69 4.95
Lb/h 90.6 91.2 92.4 94.3
Btu/h 8010 7660 7340 7040 6780
Watts 923 1000 1060 1110 1140
Amps 4.19 4.55 4.87 5.15 5.40
Lb/h 103 103 104 105 107
Btu/h 9070 8650 8240 7860 7510
Watts 936 1030 1100 1160 1210
Amps 4.30 4.67 5.01 5.33 5.62
Lb/h 117 116 116 117 118
Btu/h 10300 9750 9260 8790 8340 7930 7550
Watts 947 1050 1130 1210 1270 1330 1370
Amps 4.39 4.78 5.14 5.49 5.81 6.13 6.43
Lb/h 132 132 131 131 131 132 133
Btu/h 11600 11000 10400 9840 9290 8770 8280
Watts 956 1060 1160 1250 1330 1400 1460
Amps 4.46 4.87 5.26 5.63 5.99 6.35 6.70
Lb/h 150 148 148 147 147 147 147
Btu/h 13000 12400 11700 11000 10400 9730 9120
Watts 964 1080 1190 1280 1370 1460 1540
Amps 4.51 4.94 5.35 5.75 6.15 6.55 6.96
Lb/h 169 167 166 165 164 164 163
Btu/h 14700 13900 13100 12300 11600 10800 10100
25
30
35
40
45
50
55
Watts 970 1090 1210 1310 1420 1520 1610
Amps 4.55 5.00 5.43 5.86 6.30 6.74 7.19
Lb/h 190 189 187 185 184 183 182
Btu/h 16400 15600 14700 13800 12900 12000 11200
Watts 976 1100 1220 1340 1450 1570 1680
Amps 4.58 5.04 5.50 5.96 6.43 6.91 7.42
Lb/h 214 212 210 208 207 205 203
Btu/h 18400 17400 16400 15400 14400 13400 12400
Watts 981 1110 1240 1360 1490 1610 1730
Amps 4.59 5.07 5.55 6.04 6.55 7.08 7.63
Lb/h 241 238 236 234 232 229 227
Btu/h 20500 19400 18300 17200 16000 14900 13800
Watts 985 1120 1250 1380 1510 1650 1780
Amps 4.59 5.09 5.59 6.12 6.66 7.23 7.83
Lb/h 269 267 265 262 260 257 254
Btu/h 22800 21600 20400 19100 17900 16600 15300
Watts 990 1120 1260 1400 1540 1680 1830
Amps 4.58 5.10 5.63 6.18 6.76 7.37 8.02
Lb/h 301 299 296 294 291 288 284
Btu/h 25300 24000 22600 21300 19900 18400 17000
Watts 995 1130 1270 1410 1550 1700 1860
Amps 4.57 5.10 5.65 6.24 6.85 7.50 8.20
Lb/h 336 334 331 328 325 322 318
Btu/h 28000 26600 25100 23600 22000 20500 18900
Watts 1000 1140 1270 1420 1570 1730 1890
Amps 4.55 5.10 5.67 6.28 6.93 7.63 8.38
Lb/h 374 372 369 366 363 359 355
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.081274E+04 -4.466589E+02 -7.533005E-01 1.256847E+02
C2 2.708770E+02 -1.501652E+00 4.102224E-02 2.836684E+00
C3 -2.652987E+01 2.658773E+01 9.118630E-02 -5.568680E-01
C4 3.173198E+00 1.332172E-01 -4.100021E-04 2.114286E-02
C5 -4.220611E-01 -9.808330E-02 -7.216199E-04 3.909816E-03
C6 -1.986905E-01 -1.327392E-01 -4.372394E-04 3.603550E-03
C7 1.154944E-02 4.658937E-04 1.946123E-06 2.254056E-04
C8 -1.034406E-02 -2.327354E-03 -1.077194E-07 1.047648E-04
C9 -5.851071E-03 1.919744E-03 6.308743E-06 -8.259898E-05
C10 1.163979E-03 1.792075E-04 8.723517E-07 -2.376495E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature