Performance Data Sheet
RKA5515EXC
General Information
Model RKA5515EXC Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 240V ~ 50HZ
Return Gas 35°C (95°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 4580 4380
Watts 394 492
Amps 2.00 2.31
Lb/h 59.0 58.7
Btu/h 5030 4800 4540
Watts 420 518 608
Amps 2.15 2.47 2.75
Lb/h 64.4 63.9 63.0
Btu/h 5580 5310 5020 4710
Watts 444 543 635 720
Amps 2.29 2.62 2.91 3.17
Lb/h 71.1 70.3 69.3 67.8
Btu/h 6250 5940 5610 5250 4880
Watts 466 567 661 748 828
Amps 2.42 2.76 3.06 3.34 3.62
Lb/h 79.0 78.1 76.8 75.1 73.1
Btu/h 7020 6660 6290 5890 5480
Watts 488 589 684 775 859
Amps 2.54 2.89 3.20 3.49 3.78
Lb/h 88.2 87.0 85.5 83.6 81.4
Btu/h 7900 7490 7060 6620 6170 5700 5220
Watts 507 609 706 799 888 971 1050
Amps 2.65 3.02 3.34 3.64 3.94 4.26 4.63
Lb/h 98.6 97.2 95.4 93.3 90.9 88.2 85.1
Btu/h 8890 8420 7940 7450 6940 6420 5900
Watts 526 628 727 822 914 1000 1090
Amps 2.75 3.13 3.46 3.78 4.09 4.43 4.80
Lb/h 110 109 106 104 102 98.6 95.4
Btu/h 9990 9460 8920 8360 7800 7230 6650
Watts 543 645 745 843 939 1030 1120
Amps 2.83 3.22 3.58 3.91 4.24 4.58 4.97
Lb/h 123 121 119 116 113 110 107
Btu/h 11200 10600 9990 9370 8750 8120 7490
25
30
35
40
45
50
55
Watts 559 661 762 863 962 1060 1160
Amps 2.89 3.31 3.67 4.02 4.37 4.73 5.13
Lb/h 137 135 132 129 126 123 119
Btu/h 12500 11800 11200 10500 9780 9090 8400
Watts 573 675 777 880 983 1090 1190
Amps 2.94 3.37 3.76 4.12 4.49 4.87 5.29
Lb/h 152 150 147 143 140 136 133
Btu/h 13900 13200 12400 11700 10900 10100 9390
Watts 586 688 791 896 1000 1110 1220
Amps 2.97 3.42 3.83 4.21 4.59 4.99 5.43
Lb/h 169 166 162 159 155 151 147
Btu/h 15500 14600 13800 13000 12100 11300 10500
Watts 598 699 803 910 1020 1130 1240
Amps 2.99 3.46 3.88 4.29 4.68 5.10 5.56
Lb/h 186 183 179 175 171 167 163
Btu/h 17100 16200 15300 14300 13400 12500 11600
Watts 609 709 814 923 1030 1150 1270
Amps 2.98 3.47 3.92 4.34 4.76 5.20 5.68
Lb/h 205 201 197 193 188 184 179
Btu/h 18900 17800 16800 15800 14800 13800 12800
Watts 618 718 823 933 1050 1170 1290
Amps 2.95 3.47 3.94 4.38 4.82 5.28 5.78
Lb/h 225 220 216 211 206 201 196
Btu/h 20700 19600 18500 17400 16300 15200 14100
Watts 626 725 831 943 1060 1180 1310
Amps 2.90 3.44 3.93 4.40 4.87 5.35 5.87
Lb/h 246 241 236 231 225 220 215
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 7.945329E+03 -5.248398E+02 -4.251244E+00 7.478809E+01
C2 2.346249E+02 1.180855E+01 4.415235E-03 2.295094E+00
C3 -1.164177E+01 1.405358E+01 1.520265E-01 1.737019E-01
C4 3.001746E+00 -5.583247E-03 -4.179434E-04 2.858572E-02
C5 -1.338092E+00 -1.868159E-01 2.918687E-04 -9.367057E-03
C6 -1.277380E-01 -1.611424E-02 -1.132397E-03 -1.402430E-03
C7 -8.590031E-05 3.077260E-05 -1.461779E-06 -2.193081E-05
C8 -1.039762E-02 -2.886212E-04 2.450731E-06 -4.388214E-05
C9 2.550823E-03 1.176604E-03 -3.775861E-07 2.651780E-05
C10 1.015736E-04 -5.854927E-05 3.432282E-06 -1.366714E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature