Tecumseh RKA5515CXD Performance Data Sheet

Performance Data Sheet
RKA5515CXD
General Information
Model RKA5515CXD Refrigerant R-407C Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ Return Gas 35°C (95°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 4480 3450 Watts 668 705 Amps 3.24 3.38
Lb/h 53.2 51.8
Btu/h 5270 4320 3560 Watts 696 739 784 Amps 3.34 3.49 3.70
Lb/h 61.5 60.5 58.7
Btu/h 6120 5230 4510 3940 Watts 720 769 821 875 Amps 3.44 3.61 3.83 4.11
Lb/h 70.3 69.6 68.2 66.0
Btu/h 7020 6180 5500 4950 4460 Watts 742 796 854 915 980 Amps 3.52 3.71 3.96 4.25 4.59
Lb/h 79.8 79.4 78.2 76.3 73.8
Btu/h 7980 7170 6520 5980 5500 Watts 760 820 884 952 1020 Amps 3.59 3.80 4.07 4.39 4.75
Lb/h 90.3 90.0 89.1 87.4 85.1
Btu/h 9000 8210 7570 7030 6550 6070 5530 Watts 774 840 911 986 1060 1150 1230 Amps 3.65 3.88 4.17 4.52 4.90 5.31 5.74
Lb/h 102 102 101 99.3 97.2 94.4 91.1
Btu/h 10100 9290 8660 8110 7610 7100 6530 Watts 785 857 934 1020 1100 1190 1290 Amps 3.70 3.95 4.26 4.63 5.04 5.48 5.93
Lb/h 115 114 114 112 110 108 104
Btu/h 11200 10400 9780 9220 8680 8130 7510 Watts 791 869 953 1040 1130 1230 1330 Amps 3.73 4.00 4.34 4.73 5.17 5.63 6.12
Lb/h 129 129 128 126 124 122 119
Btu/h 12400 11600 11000 10400 9780 9170 8490
25
30
35
40
45
50
55
Watts 793 878 968 1060 1160 1270 1380 Amps 3.75 4.04 4.40 4.82 5.28 5.78 6.29
Lb/h 145 144 143 142 140 137 134
Btu/h 13700 12900 12200 11500 10900 10200 9470 Watts 791 882 978 1080 1190 1300 1420 Amps 3.74 4.06 4.45 4.89 5.38 5.91 6.45
Lb/h 162 162 161 159 157 154 151
Btu/h 15100 14200 13400 12700 12000 11300 10400 Watts 784 881 984 1090 1210 1330 1460 Amps 3.73 4.07 4.48 4.95 5.47 6.02 6.60
Lb/h 182 181 180 178 175 173 169
Btu/h 16500 15600 14800 14000 13200 12400 11400 Watts 773 876 986 1100 1220 1350 1490 Amps 3.69 4.05 4.49 4.99 5.54 6.12 6.72
Lb/h 203 202 200 198 196 193 189
Btu/h 18000 17000 16100 15300 14400 13500 12400 Watts 756 866 982 1110 1230 1370 1510 Amps 3.63 4.02 4.48 5.01 5.59 6.20 6.84
Lb/h 227 225 223 221 218 215 211
Btu/h 19600 18500 17500 16600 15600 14600 13400 Watts 735 851 974 1100 1240 1390 1540 Amps 3.55 3.96 4.46 5.01 5.62 6.26 6.93
Lb/h 253 251 249 246 242 239 234
Btu/h 21200 20100 19000 18000 16900 15700 14400 Watts 708 830 960 1100 1240 1390 1550 Amps 3.44 3.89 4.41 4.99 5.63 6.30 7.01
Lb/h 282 279 276 273 269 265 260
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.622472E+04 4.409316E+02 5.565411E+00 5.387348E+01 C2 5.265653E+01 -2.744703E+00 -5.924276E-03 1.865491E+00 C3 -4.392211E+02 2.134168E+00 -7.910517E-02 6.739398E-01 C4 3.051013E+00 -7.506870E-02 -3.220182E-04 3.034775E-02 C5 2.437306E+00 5.245088E-02 1.575128E-04 -7.014152E-04 C6 3.172673E+00 2.174208E-02 8.241193E-04 -4.649668E-03 C7 3.453194E-03 -2.534712E-04 -1.684188E-06 2.244992E-04 C8 -2.406766E-02 7.812346E-05 1.332633E-06 -1.510256E-04 C9 -9.638544E-03 3.881184E-04 1.381942E-06 2.902954E-05
C10 -8.530078E-03 -1.751419E-05 -1.939776E-06 3.456840E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...