Performance Data Sheet
RKA5513EXA
General Information
Model RKA5513EXA Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 4860 4560
Watts 566 623
Amps 5.04 5.46
Lb/h 62.5 61.2
Btu/h 5370 5050 4730
Watts 581 641 701
Amps 5.13 5.61 6.14
Lb/h 68.7 67.2 65.8
Btu/h 5980 5620 5270 4940
Watts 595 659 723 786
Amps 5.23 5.77 6.35 6.98
Lb/h 76.0 74.4 72.8 71.3
Btu/h 6670 6290 5910 5540 5190
Watts 610 677 744 812 880
Amps 5.33 5.93 6.57 7.24 7.95
Lb/h 84.4 82.6 80.9 79.2 77.7
Btu/h 7470 7040 6630 6220 5830
Watts 624 694 765 837 910
Amps 5.43 6.09 6.78 7.50 8.26
Lb/h 93.8 92.0 90.1 88.3 86.6
Btu/h 8360 7900 7440 6990 6550 6130 5710
Watts 638 711 786 861 939 1020 1100
Amps 5.54 6.25 6.99 7.76 8.55 9.38 10.3
Lb/h 104 102 100 98.5 96.6 94.8 93.2
Btu/h 9340 8840 8340 7850 7360 6890 6420
Watts 653 728 806 885 966 1050 1140
Amps 5.65 6.41 7.20 8.01 8.84 9.71 10.6
Lb/h 116 114 112 110 108 106 104
Btu/h 10400 9870 9330 8790 8260 7740 7220
Watts 667 745 825 908 993 1080 1170
Amps 5.76 6.58 7.41 8.25 9.12 10.0 10.9
Lb/h 128 126 124 122 120 118 116
Btu/h 11600 11000 10400 9830 9240 8660 8090
25
30
35
40
45
50
55
Watts 682 761 844 930 1020 1110 1210
Amps 5.88 6.74 7.61 8.49 9.39 10.3 11.3
Lb/h 142 140 138 135 133 131 129
Btu/h 12900 12200 11600 10900 10300 9680 9050
Watts 696 778 863 952 1040 1140 1240
Amps 5.99 6.90 7.81 8.73 9.66 10.6 11.6
Lb/h 157 155 152 150 148 145 143
Btu/h 14200 13500 12800 12100 11500 10800 10100
Watts 711 794 882 973 1070 1170 1270
Amps 6.11 7.06 8.00 8.95 9.91 10.9 11.9
Lb/h 172 170 168 165 163 160 158
Btu/h 15700 14900 14200 13400 12700 11900 11200
Watts 726 811 900 993 1090 1190 1300
Amps 6.23 7.22 8.20 9.18 10.2 11.1 12.1
Lb/h 189 187 184 182 179 177 174
Btu/h 17200 16400 15600 14800 14000 13200 12400
Watts 741 827 918 1010 1110 1220 1330
Amps 6.35 7.37 8.38 9.39 10.4 11.4 12.4
Lb/h 206 204 202 199 197 194 191
Btu/h 18900 18000 17200 16300 15400 14500 13700
Watts 757 843 935 1030 1140 1240 1360
Amps 6.47 7.53 8.57 9.60 10.6 11.6 12.7
Lb/h 225 222 220 218 215 212 209
Btu/h 20600 19700 18800 17800 16900 16000 15000
Watts 773 860 953 1050 1160 1270 1390
Amps 6.59 7.68 8.74 9.79 10.8 11.9 12.9
Lb/h 244 242 239 237 234 231 229
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 9.988236E+03 8.763372E+01 1.180036E+00 9.305157E+01
C2 1.898539E+02 1.461676E+00 -1.056255E-01 1.807020E+00
C3 -4.180823E+01 6.376495E+00 4.890128E-02 3.761910E-03
C4 2.273681E+00 3.930066E-02 4.950495E-04 1.923133E-02
C5 -3.498387E-01 -2.375555E-02 1.947268E-03 1.472206E-03
C6 -1.510284E-02 1.825593E-03 -1.645788E-05 -2.011916E-03
C7 -2.243695E-04 4.893074E-05 -5.290295E-07 -2.290368E-05
C8 -4.703070E-03 -5.032708E-04 -5.233321E-06 2.836047E-05
C9 -1.957826E-03 5.163456E-04 -4.637892E-06 -2.177738E-05
C10 2.496377E-04 6.948478E-07 6.613960E-07 7.602152E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature