Model: RKA5512YUZ (RK5512Y)
Product Description
Type: Rotary
Application: HBP/AC - Air Conditioning
Refrigerant: R-134a
Voltage/Frequency: 230V ~ 60Hz 230V ~ 50Hz
Version: N/A
Product Specifications
Technical Data Sheet
2/13/2015
Performance
Refrigeration Capacity Input Power Efficiency
Condition Test Voltage Btu/h kcal/h W W Btu/Wh kcal/Wh W/W
EN12900
ASERCOM
EN12900
ASERCOM
230V ~ 60HZ 10085 2541 2955 1042 9.68 2.44 2.84 5°C (41°F) 50°C (122°F) 32°C (90°F) 15°C (59°F) 50°C (122°F)
230V ~ 50HZ 8331 2099 2441 884 9.42 2.37 2.76 5°C (41°F) 50°C (122°F) 32°C (90°F) 15°C (59°F) 50°C (122°F)
General
Evaporating Temp. Range: -15°C to 15°C (5°F to 59°F)
Motor Torque: Low Start Torque (LST)
Compressor Cooling: Fan
Mechanical
Weight: 14
Weight Unit of Measure: KG
Displacement (cc): 24.4
Oil Type: Polyvinylether
Viscosity (cSt): 68
Oil Charge (cc): 444
Electrical
Voltage Range (50 Hz): 207-253
Voltage Range (60 Hz): 207-253
Locked Rotor Amps (LRA): 30
Rated Load Amps (RLA 50 Hz): 5.4
Rated Load Amps (RLA 60 Hz): 4.8
Max. Continuous Current (MCC in Amps): 8.4
Motor Resistance (Ohm) - Main: 2.2
Motor Resistance (Ohm) - Start: 4.9
Motor Type: PSC
Overload Type: N/A
Relay Type: N/A
EVAP TEMP COND
TEMP
AMBIENT
TEMP
RETURN
GAS
LIQUID
TEMP
Agency Approval
CE Listed, GOST RUSSIA Listed, cURus
Recognized