Performance Data Sheet
RKA5510EXV
General Information
Model RKA5510EXV Refrigerant R-22
Test Condition ASHRAE Performance Test Voltage 265V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 3790 3560
Watts 489 518
Amps 1.63 1.77
Lb/h 48.7 47.7
Btu/h 4190 3940 3690
Watts 490 522 559
Amps 1.66 1.82 2.00
Lb/h 53.6 52.4 51.3
Btu/h 4660 4380 4120 3860
Watts 493 529 569 615
Amps 1.70 1.87 2.06 2.27
Lb/h 59.3 58.0 56.8 55.6
Btu/h 5210 4900 4610 4320 4050
Watts 498 537 581 630 683
Amps 1.73 1.92 2.13 2.35 2.59
Lb/h 65.8 64.5 63.1 61.8 60.6
Btu/h 5830 5500 5170 4850 4550
Watts 504 547 594 646 703
Amps 1.77 1.98 2.20 2.43 2.68
Lb/h 73.2 71.8 70.3 68.9 67.6
Btu/h 6520 6160 5800 5460 5110 4780 4450
Watts 513 558 609 664 724 788 856
Amps 1.81 2.03 2.26 2.51 2.77 3.04 3.33
Lb/h 81.4 79.9 78.4 76.9 75.4 74.0 72.7
Btu/h 7290 6900 6510 6120 5750 5380 5010
Watts 522 570 624 682 745 812 883
Amps 1.85 2.09 2.33 2.59 2.86 3.14 3.44
Lb/h 90.4 88.9 87.3 85.7 84.1 82.5 81.1
Btu/h 8130 7700 7280 6860 6450 6040 5630
Watts 532 583 639 700 766 836 911
Amps 1.89 2.14 2.40 2.67 2.95 3.24 3.55
Lb/h 100 98.7 97.0 95.3 93.6 91.9 90.4
Btu/h 9040 8580 8120 7670 7210 6760 6310
25
30
35
40
45
50
55
Watts 543 596 655 719 788 861 938
Amps 1.93 2.19 2.47 2.75 3.04 3.34 3.65
Lb/h 111 109 107 106 104 102 101
Btu/h 10000 9540 9040 8540 8040 7550 7060
Watts 554 610 671 737 809 884 965
Amps 1.96 2.25 2.53 2.82 3.12 3.43 3.75
Lb/h 122 121 119 117 115 113 111
Btu/h 11100 10600 10000 9480 8940 8400 7870
Watts 565 623 687 755 829 907 990
Amps 2.00 2.30 2.60 2.90 3.21 3.52 3.85
Lb/h 134 133 131 129 127 125 123
Btu/h 12200 11700 11100 10500 9900 9320 8730
Watts 576 636 702 773 849 929 1010
Amps 2.04 2.35 2.66 2.97 3.29 3.61 3.94
Lb/h 147 146 144 142 140 138 136
Btu/h 13400 12800 12200 11600 10900 10300 9670
Watts 586 648 716 789 867 950 1040
Amps 2.08 2.40 2.72 3.05 3.37 3.70 4.04
Lb/h 161 159 157 155 153 151 149
Btu/h 14700 14100 13400 12700 12000 11300 10700
Watts 596 660 729 804 884 969 1060
Amps 2.11 2.45 2.78 3.11 3.45 3.78 4.13
Lb/h 175 174 172 170 168 166 163
Btu/h 16100 15400 14600 13900 13200 12500 11700
Watts 604 670 741 818 899 986 1080
Amps 2.15 2.49 2.84 3.18 3.52 3.86 4.21
Lb/h 190 189 187 185 183 181 178
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 7.794201E+03 3.716519E+02 3.965338E-01 7.266941E+01
C2 1.486647E+02 -3.461545E+00 -2.987411E-02 1.417760E+00
C3 -3.280041E+01 -7.327693E-01 1.700086E-02 -1.179288E-03
C4 1.775097E+00 5.952075E-02 8.017797E-05 1.502688E-02
C5 -2.827346E-01 5.168124E-02 5.910814E-04 1.000640E-03
C6 -8.683618E-03 3.110631E-02 -3.191797E-05 -1.509730E-03
C7 -1.581024E-04 -3.646683E-04 -4.228746E-07 -1.762463E-05
C8 -3.694062E-03 -3.214967E-04 -6.626961E-07 2.171551E-05
C9 -1.478262E-03 7.972291E-05 -1.582472E-06 -1.622541E-05
C10 1.807948E-04 -2.819691E-05 3.520143E-07 5.678109E-06
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature