Tecumseh RKA5510CXA Performance Data Sheet

Performance Data Sheet
RKA5510CXA
General Information
Model RKA5510CXA Refrigerant R-407C Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 2350 2360 Watts 445 478 Amps 4.00 4.28
Lb/h 32.4 32.6
Btu/h 2930 2880 2830 Watts 464 502 540 Amps 4.18 4.50 4.84
Lb/h 39.4 39.4 39.5
Btu/h 3590 3470 3350 3230 Watts 480 523 566 610 Amps 4.33 4.70 5.08 5.46
Lb/h 47.0 46.8 46.7 46.7
Btu/h 4300 4120 3930 3750 3570 Watts 494 541 589 638 687 Amps 4.45 4.87 5.29 5.72 6.16
Lb/h 55.2 54.9 54.7 54.4 54.2
Btu/h 5070 4830 4580 4330 4090 Watts 505 557 610 663 717 Amps 4.55 5.01 5.47 5.95 6.43
Lb/h 64.1 63.6 63.2 62.8 62.4
Btu/h 5910 5600 5290 4980 4670 4360 4050 Watts 513 571 628 687 745 805 865 Amps 4.61 5.12 5.63 6.15 6.67 7.21 7.76
Lb/h 73.5 72.9 72.3 71.8 71.2 70.7 70.3
Btu/h 6800 6430 6050 5680 5310 4940 4570 Watts 519 581 644 707 771 835 900 Amps 4.65 5.20 5.75 6.32 6.89 7.47 8.07
Lb/h 83.6 82.8 82.1 81.4 80.7 80.0 79.4
Btu/h 7750 7320 6880 6450 6010 5570 5140 Watts 522 590 657 725 794 863 933 Amps 4.66 5.26 5.86 6.46 7.08 7.71 8.34
Lb/h 94.2 93.3 92.5 91.6 90.8 89.9 89.2
Btu/h 8770 8270 7770 7270 6770 6270 5770
25
30
35
40
45
50
55
Watts 523 595 668 741 815 889 964 Amps 4.65 5.29 5.93 6.58 7.24 7.91 8.60
Lb/h 106 104 103 102 101 100 99.5
Btu/h 9840 9280 8710 8150 7590 7030 6470 Watts 521 598 676 754 833 912 992 Amps 4.62 5.30 5.99 6.68 7.39 8.10 8.82
Lb/h 117 116 115 114 113 112 111
Btu/h 11000 10300 9720 9090 8470 7850 7220 Watts 516 598 681 764 848 932 1020 Amps 4.56 5.29 6.02 6.76 7.50 8.26 9.03
Lb/h 130 128 127 126 125 123 122
Btu/h 12200 11500 10800 10100 9410 8720 8040 Watts 508 595 684 772 861 950 1040 Amps 4.49 5.26 6.03 6.81 7.60 8.40 9.21
Lb/h 143 141 140 139 137 136 134
Btu/h 13400 12600 11900 11200 10400 9650 8910 Watts 497 590 683 777 871 965 1060 Amps 4.39 5.20 6.02 6.85 7.68 8.52 9.37
Lb/h 156 155 153 152 150 149 147
Btu/h 14700 13900 13100 12300 11500 10600 9840 Watts 483 582 680 779 878 977 1080 Amps 4.28 5.13 5.99 6.86 7.74 8.62 9.51
Lb/h 171 169 167 165 164 162 161
Btu/h 16000 15200 14300 13400 12600 11700 10800 Watts 467 570 674 778 882 987 1090 Amps 4.14 5.04 5.95 6.86 7.77 8.70 9.64
Lb/h 185 183 182 180 178 176 174
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 5.772537E+03 1.217926E+02 1.255938E+00 5.789059E+01 C2 2.502863E+02 -5.570498E+00 -5.253806E-02 1.947966E+00 C3 -1.836746E+01 4.668210E+00 4.026774E-02 -3.231501E-02 C4 1.174734E+00 -5.798800E-02 -5.449374E-04 1.174046E-02 C5 -1.261092E+00 1.033857E-01 9.433062E-04 -2.822837E-03 C6 -2.391927E-03 -1.393736E-03 -2.068708E-05 -7.389206E-05 C7 -7.439695E-04 -5.088755E-05 1.528047E-06 -7.179633E-06 C8 5.681854E-04 8.448838E-05 -3.824355E-07 7.656708E-06 C9 -1.087742E-04 -3.448511E-05 -2.370798E-07 -2.234699E-06
C10 2.126659E-05 1.443517E-05 2.133686E-07 7.306002E-07
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...