Performance Data Sheet
RGA5485BXD
General Information
Model RGA5485BXD Refrigerant R-410A
Test Condition ASHRAE Performance Test Voltage 230V ~ 60HZ
Return Gas -6.7°C (20°F) SUPERHEAT Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 2650 2700
Watts 459 500
Amps 2.09 2.33
Lb/h 34.2 34.1
Btu/h 3090 3080 3060
Watts 472 516 561
Amps 2.15 2.39 2.64
Lb/h 39.0 38.7 38.3
Btu/h 3600 3510 3430 3340
Watts 482 530 579 629
Amps 2.19 2.45 2.71 2.98
Lb/h 44.5 43.9 43.3 42.7
Btu/h 4160 4010 3860 3700 3540
Watts 488 541 594 648 703
Amps 2.22 2.49 2.76 3.04 3.32
Lb/h 50.7 49.9 49.0 48.2 47.2
Btu/h 4790 4570 4350 4130 3900
Watts 492 548 606 664 723
Amps 2.24 2.52 2.81 3.10 3.39
Lb/h 57.6 56.5 55.4 54.3 53.1
Btu/h 5490 5200 4910 4620 4320 4030 3730
Watts 493 554 615 677 740 804 870
Amps 2.25 2.54 2.84 3.14 3.45 3.76 4.08
Lb/h 65.1 63.8 62.5 61.1 59.7 58.2 56.7
Btu/h 6250 5890 5530 5170 4810 4440 4080
Watts 492 556 621 687 754 823 892
Amps 2.25 2.56 2.87 3.18 3.50 3.82 4.15
Lb/h 73.3 71.8 70.2 68.5 66.9 65.2 63.4
Btu/h 7070 6640 6210 5780 5350 4920 4490
Watts 488 556 626 696 766 839 912
Amps 2.24 2.56 2.88 3.21 3.53 3.87 4.21
Lb/h 82.2 80.4 78.6 76.7 74.8 72.8 70.8
Btu/h 7960 7460 6960 6460 5970 5460 4960
25
30
35
40
45
50
55
Watts 481 554 627 701 776 852 929
Amps 2.23 2.56 2.89 3.22 3.56 3.91 4.26
Lb/h 91.8 89.7 87.6 85.5 83.4 81.1 78.9
Btu/h 8910 8340 7780 7210 6640 6070 5500
Watts 473 549 627 705 783 863 944
Amps 2.20 2.54 2.89 3.23 3.59 3.94 4.31
Lb/h 102 99.7 97.4 95.0 92.6 90.1 87.6
Btu/h 9930 9290 8650 8020 7380 6740 6100
Watts 462 543 624 706 788 872 957
Amps 2.17 2.52 2.88 3.24 3.60 3.97 4.34
Lb/h 113 110 108 105 103 99.8 97.1
Btu/h 11000 10300 9600 8890 8180 7480 6770
Watts 449 534 619 705 791 879 968
Amps 2.13 2.49 2.86 3.23 3.60 3.98 4.37
Lb/h 125 122 119 116 113 110 107
Btu/h 12200 11400 10600 9830 9050 8270 7500
Watts 434 523 612 702 792 884 976
Amps 2.08 2.46 2.84 3.22 3.60 3.99 4.39
Lb/h 137 134 131 128 124 121 118
Btu/h 13400 12500 11700 10800 9980 9140 8290
Watts 418 510 603 697 791 887 983
Amps 2.03 2.41 2.80 3.20 3.59 4.00 4.40
Lb/h 150 147 143 140 136 133 129
Btu/h 14600 13700 12800 11900 11000 10100 9150
Watts 399 496 593 690 789 888 988
Amps 1.96 2.36 2.77 3.17 3.58 3.99 4.41
Lb/h 164 160 156 153 149 145 141
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 5.365783E+03 8.164330E+01 1.237895E-01 5.670155E+01
C2 2.300914E+02 -5.679364E+00 -1.474023E-02 1.716805E+00
C3 -1.508196E+01 5.112887E+00 2.637742E-02 -7.645793E-02
C4 1.299342E+00 -5.477176E-02 -2.104387E-04 1.385424E-02
C5 -1.387578E+00 8.661759E-02 2.634912E-04 -5.299952E-03
C6 3.522218E-03 -2.255540E-03 -1.208857E-05 9.436722E-05
C7 2.360853E-04 1.346068E-04 4.661785E-07 -5.049386E-07
C8 -3.265251E-04 -1.310065E-05 7.206967E-08 -3.112509E-06
C9 1.149502E-04 -3.221540E-05 -1.782499E-07 1.908505E-06
C10 -3.684644E-05 2.327740E-05 1.215045E-07 -9.591189E-07
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature