Performance Data Sheet
HGA5512EXA
General Information
Model HGA5512EXA Refrigerant R22
Test Condition ASHRAE Test Voltage 115V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 4010 3900
Watts 502 579
Amps 6.46 6.72
Lb/h 51.8 52.4
Btu/h 4580 4430 4250
Watts 528 609 663
Amps 6.52 6.82 7.09
Lb/h 58.9 59.1 59.1
Btu/h 5210 5020 4790 4550
Watts 550 635 694 735
Amps 6.58 6.93 7.25 7.54
Lb/h 66.5 66.5 66.2 65.7
Btu/h 5900 5670 5400 5100 4810
Watts 568 656 721 768 803
Amps 6.64 7.02 7.40 7.75 8.08
Lb/h 74.7 74.6 73.9 73.0 72.2
Btu/h 6640 6380 6060 5710 5370
Watts 583 674 743 797 840
Amps 6.70 7.12 7.53 7.95 8.36
Lb/h 83.7 83.3 82.4 81.1 79.8
Btu/h 7460 7150 6790 6390 5980 5600 5260
Watts 594 687 761 821 873 922 974
Amps 6.75 7.20 7.66 8.13 8.61 9.08 9.55
Lb/h 93.3 92.8 91.6 90.0 88.2 86.7 85.6
Btu/h 8340 8000 7580 7130 6660 6210 5800
Watts 601 697 775 841 900 959 1020
Amps 6.79 7.27 7.77 8.30 8.84 9.39 9.95
Lb/h 104 103 102 99.7 97.5 95.5 93.8
Btu/h 9300 8910 8450 7940 7420 6900 6410 5980
Watts 605 704 786 857 924 992 1070 1150
Amps 6.82 7.33 7.87 8.44 9.05 9.68 10.3 11.0
Lb/h 115 114 112 110 108 105 103 101
Btu/h 10300 9900 9390 8830 8240 7650 7090 6590
25
30
35
40
45
50
55
Watts 607 707 793 870 944 1020 1110 1210
Amps 6.84 7.37 7.94 8.56 9.23 9.93 10.7 11.4
Lb/h 127 126 124 122 119 116 113 111
Btu/h 11400 11000 10400 9790 9140 8490 7850 7260
Watts 606 708 797 879 960 1050 1140 1250
Amps 6.84 7.39 7.99 8.66 9.38 10.2 11.0 11.8
Lb/h 139 139 137 134 131 127 124 121
Btu/h 12600 12100 11500 10800 10100 9400 8690 8020
Watts 602 705 798 885 972 1070 1170 1290
Amps 6.82 7.38 8.02 8.73 9.50 10.3 11.2 12.2
Lb/h 153 152 150 147 144 140 136 133
Btu/h 13900 13300 12700 12000 11200 10400 9600 8850
Watts 596 701 796 887 981 1080 1200 1330
Amps 6.78 7.36 8.02 8.77 9.59 10.5 11.5 12.5
Lb/h 167 167 165 162 158 154 150 145
Btu/h 15300 14700 14000 13200 12300 11500 10600 9770
Watts 588 694 791 887 987 1100 1220 1370
Amps 6.72 7.31 7.99 8.77 9.65 10.6 11.6 12.8
Lb/h 183 182 180 177 173 169 164 159
Btu/h 16700 16100 15300 14500 13600 12600 11700 10800
Watts 579 684 784 884 990 1110 1240 1400
Amps 6.63 7.22 7.93 8.74 9.66 10.7 11.8 13.0
Lb/h 199 199 197 193 189 184 179 174
Btu/h 18300 17600 16800 15900 14900 13900 12900 11900
Watts 568 674 776 879 990 1110 1260 1430
Amps 6.51 7.11 7.83 8.67 9.63 10.7 11.9 13.2
Lb/h 217 216 214 211 207 202 196 191
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.764809E+03 -1.658302E+03 3.669167E+00 2.271770E+01
C2 1.583240E+02 1.076889E+01 4.358724E-02 1.320330E+00
C3 1.263746E+02 5.165965E+01 3.073141E-02 1.593127E+00
C4 1.345080E+00 -3.184582E-02 4.284935E-04 8.264708E-03
C5 3.340666E-01 -2.336389E-01 -1.397819E-03 1.275366E-02
C6 -1.449199E+00 -3.743971E-01 1.394221E-04 -1.567645E-02
C7 4.441013E-03 2.931045E-04 -3.428722E-06 4.516056E-05
C8 -1.254582E-03 -5.446193E-04 -6.193218E-06 6.181964E-05
C9 -6.528612E-03 1.744971E-03 1.249575E-05 -9.772023E-05
C10 4.486479E-03 9.571331E-04 -7.406299E-07 4.863731E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature