Tecumseh HGA5492EXV User Manual

Performance Data Sheet
HGA5492EXV
General Information
Model HGA5492EXV Refrigerant R22 Test Condition ASHRAE Test Voltage 265V ~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 2940 2770 Watts 430 462 Amps 1.60 1.78
Lb/h 38.0 37.4
Btu/h 3460 3260 3090 Watts 442 475 511 Amps 1.63 1.80 2.01
Lb/h 44.4 43.6 43.2
Btu/h 4010 3780 3580 3400 Watts 452 488 526 566 Amps 1.66 1.83 2.03 2.25
Lb/h 51.1 50.1 49.5 49.2
Btu/h 4600 4340 4100 3880 3680 Watts 462 501 541 583 627 Amps 1.70 1.86 2.05 2.27 2.51
Lb/h 58.2 57.0 56.2 55.6 55.2
Btu/h 5230 4930 4660 4400 4160 Watts 470 512 555 600 648 Amps 1.73 1.89 2.09 2.30 2.54
Lb/h 65.7 64.4 63.3 62.5 61.8
Btu/h 5900 5570 5260 4960 4670 4390 4110 Watts 477 521 568 617 667 720 774 Amps 1.76 1.93 2.12 2.34 2.58 2.83 3.09
Lb/h 73.7 72.2 70.9 69.9 68.9 67.9 66.8
Btu/h 6610 6250 5900 5570 5240 4910 4570 Watts 481 529 579 631 686 742 800 Amps 1.79 1.96 2.16 2.38 2.62 2.87 3.14
Lb/h 82.1 80.5 79.1 77.8 76.5 75.2 73.8
Btu/h 7380 6980 6600 6220 5840 5470 5080 4690 Watts 483 534 588 644 702 763 826 890 Amps 1.81 1.99 2.19 2.42 2.66 2.92 3.19 3.46
Lb/h 91.0 89.3 87.8 86.3 84.8 83.2 81.4 79.4
Btu/h 8200 7770 7340 6920 6500 6080 5640 5190
25
30
35
40
45
50
55
Watts 482 537 595 655 717 782 850 919 Amps 1.82 2.01 2.22 2.46 2.71 2.97 3.24 3.52
Lb/h 101 98.7 97.1 95.4 93.7 91.8 89.7 87.3
Btu/h 9080 8610 8150 7690 7220 6750 6260 5750 Watts 477 537 599 663 730 800 872 946 Amps 1.81 2.02 2.24 2.49 2.75 3.03 3.31 3.59
Lb/h 111 109 107 105 103 101 98.8 96.0
Btu/h 10000 9510 9010 8510 8000 7470 6930 6370 Watts 470 533 600 669 741 815 892 971 Amps 1.79 2.01 2.26 2.52 2.79 3.08 3.37 3.67
Lb/h 121 119 118 116 114 111 109 106
Btu/h 11000 10500 9940 9390 8830 8260 7670 7050 Watts 458 526 597 671 748 828 910 994 Amps 1.75 1.99 2.26 2.53 2.83 3.13 3.43 3.74
Lb/h 133 131 129 127 125 122 119 116
Btu/h 12100 11500 10900 10300 9740 9120 8470 7790 Watts 442 515 591 670 752 837 925 1020 Amps 1.69 1.96 2.24 2.54 2.85 3.17 3.49 3.82
Lb/h 145 143 141 139 137 134 131 127
Btu/h 13200 12600 12000 11400 10700 10000 9340 8610 Watts 422 500 581 665 753 843 937 1030 Amps 1.61 1.90 2.21 2.53 2.86 3.20 3.55 3.89
Lb/h 158 156 154 152 149 147 143 139
Btu/h 14500 13800 13100 12500 11800 11000 10300 9490 Watts 396 480 566 656 749 846 945 1050 Amps 1.50 1.82 2.15 2.50 2.86 3.22 3.59 3.95
Lb/h 171 170 168 166 163 160 157 152
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 8.135906E+03 2.304985E+02 1.929012E+00 9.071826E+01 C2 1.491527E+02 -1.482127E+00 2.145092E-03 1.386932E+00 C3 -6.564044E+01 1.924526E+00 -2.478093E-02 -7.635496E-01 C4 8.814793E-01 -6.807811E-02 -4.670771E-04 4.335921E-03 C5 -8.629374E-02 2.941703E-02 1.512176E-04 4.804332E-03 C6 3.286743E-01 1.332331E-02 3.258751E-04 5.608434E-03 C7 5.028549E-03 -4.615244E-04 -3.486483E-06 5.295936E-05 C8 -1.244473E-03 4.890497E-04 5.795720E-06 4.541810E-05 C9 -3.282529E-03 1.446129E-04 -1.113937E-06 -4.873116E-05
C10 -7.590114E-04 -1.504350E-05 -6.558801E-07 -1.425992E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature