Performance Data Sheet
AWG5524EXC
General Information
Model AWG5524EXC Refrigerant R22
Test Condition ARI Test Voltage 220V ~ 50HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type PSC
Performance Information
Evap Temp (°F)
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140 150
Btu/h 5380 4690
Watts 902 915
Amps 4.25 4.27
Lb/h 69.0 63.1
Btu/h 6660 5900 5150
Watts 973 991 1000
Amps 4.61 4.66 4.68
Lb/h 85.1 78.8 72.1
Btu/h 8030 7200 6370 5550
Watts 1040 1060 1080 1090
Amps 4.94 5.02 5.08 5.11
Lb/h 102 95.3 88.1 80.4
Btu/h 9500 8580 7680 6770 5870
Watts 1100 1130 1160 1180 1180
Amps 5.23 5.35 5.46 5.53 5.56
Lb/h 120 113 105 97.0 88.2
Btu/h 11100 10100 9080 8090 7100
Watts 1150 1200 1230 1260 1280
Amps 5.48 5.64 5.80 5.93 6.01
Lb/h 139 132 123 115 106
Btu/h 12800 11700 10600 9520 8430 7350 6260
Watts 1200 1250 1300 1340 1370 1380 1370
Amps 5.71 5.91 6.11 6.30 6.44 6.52 6.50
Lb/h 160 152 143 134 124 114 102
Btu/h 14600 13400 12200 11100 9880 8700 7510
Watts 1250 1310 1370 1420 1460 1490 1490
Amps 5.89 6.14 6.40 6.64 6.85 7.00 7.06
Lb/h 182 173 164 155 144 133 121
Btu/h 16600 15300 14000 12700 11500 10200 8870 7560
Watts 1280 1350 1420 1490 1550 1590 1610 1610
Amps 6.04 6.34 6.65 6.96 7.23 7.45 7.59 7.63
Lb/h 205 196 187 177 166 155 142 128
Btu/h 18800 17400 16000 14600 13200 11800 10400 8950
25
30
35
40
45
50
55
Watts 1310 1390 1470 1550 1630 1690 1730 1750
Amps 6.16 6.51 6.88 7.24 7.59 7.89 8.11 8.24
Lb/h 230 221 211 201 190 178 165 150
Btu/h 21100 19600 18100 16600 15000 13500 12000 10500
Watts 1330 1420 1520 1610 1700 1780 1840 1880
Amps 6.24 6.64 7.07 7.50 7.92 8.30 8.61 8.83
Lb/h 257 247 237 227 215 203 189 175
Btu/h 23600 22000 20300 18700 17100 15400 13800 12100
Watts 1340 1440 1560 1670 1770 1870 1950 2010
Amps 6.28 6.74 7.23 7.74 8.23 8.69 9.09 9.40
Lb/h 286 276 266 255 243 230 216 201
Btu/h 26300 24600 22800 21100 19300 17500 15800 14000
Watts 1340 1460 1590 1710 1840 1950 2050 2140
Amps 6.29 6.80 7.36 7.94 8.51 9.06 9.55 9.96
Lb/h 317 307 296 285 272 259 245 229
Btu/h 29300 27400 25500 23600 21700 19800 17900 16000
Watts 1330 1460 1610 1750 1890 2030 2150 2260
Amps 6.25 6.83 7.46 8.11 8.77 9.40 9.99 10.5
Lb/h 351 340 329 317 304 291 276 260
Btu/h 32400 30400 28400 26300 24300 22300 20200 18200
Watts 1310 1460 1620 1780 1950 2100 2250 2380
Amps 6.18 6.83 7.53 8.26 9.00 9.72 10.4 11.0
Lb/h 386 375 364 352 339 325 310 294
Btu/h 35900 33700 31500 29300 27100 25000 22800 20600
Watts 1280 1450 1620 1810 1990 2170 2330 2490
Amps 6.08 6.79 7.56 8.37 9.20 10.0 10.8 11.5
Lb/h 425 413 402 389 376 362 346 330
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.746155E+04 1.164099E+03 6.815224E+00 1.844740E+02
C2 4.354200E+02 8.709238E+00 3.954955E-02 4.342958E+00
C3 -1.107233E+02 -9.900467E+00 -7.671631E-02 -1.076384E+00
C4 3.157215E+00 -2.399407E-01 -1.140851E-03 2.088796E-02
C5 -1.614469E+00 -7.284560E-02 -3.219692E-04 -7.144455E-03
C6 1.827378E-01 1.740085E-01 1.028559E-03 5.610381E-03
C7 1.716214E-02 -6.931092E-04 -4.571286E-07 1.864013E-04
C8 -1.144554E-02 1.567205E-03 5.624388E-06 2.693046E-05
C9 -3.437165E-04 1.366891E-03 6.413663E-06 -9.911393E-06
C10 -5.406809E-04 -7.540277E-04 -3.972366E-06 -2.773475E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature