Tecumseh AWG5515EXT Performance Data Sheet

Performance Data Sheet
AWG5515EXT
General Information
Model AWG5515EXT Refrigerant R-22 Test Condition ARI Performance Test Voltage 230V 3~ 60HZ Return Gas 18.3°C (65°F) RETURN GAS Motor Type 3PH
Performance Information
-15
-10
-5
0
5
10
15
20
Condensing Temperature (°F)
80 90 100 110 120 130 140
Btu/h 3640 3290 Watts 718 700 Amps 3.08 3.09
Lb/h 47.2 44.2
Btu/h 4360 3910 3460 Watts 757 747 733 Amps 3.16 3.18 3.17
Lb/h 56.0 52.2 48.1
Btu/h 5270 4720 4170 3630 Watts 798 797 790 780 Amps 3.24 3.27 3.27 3.25
Lb/h 67.2 62.6 57.6 52.3
Btu/h 6380 5720 5070 4420 3790 Watts 840 848 850 847 840 Amps 3.31 3.36 3.38 3.37 3.34
Lb/h 80.7 75.3 69.4 63.2 56.8
Btu/h 7670 6910 6140 5380 4640 Watts 881 900 911 917 917 Amps 3.38 3.44 3.48 3.49 3.48
Lb/h 96.4 90.2 83.5 76.5 69.1
Btu/h 9150 8280 7400 6520 5660 4840 4070 Watts 921 951 973 987 995 997 994 Amps 3.44 3.52 3.58 3.61 3.62 3.61 3.58
Lb/h 114 107 99.9 91.9 83.6 75.0 66.2
Btu/h 10800 9820 8830 7830 6850 5900 5000 Watts 957 1000 1030 1060 1070 1080 1090 Amps 3.50 3.60 3.67 3.72 3.75 3.77 3.76
Lb/h 134 127 118 110 100 90.8 80.9
Btu/h 12600 11500 10400 9310 8200 7130 6100 Watts 989 1040 1090 1130 1150 1170 1180 Amps 3.54 3.66 3.76 3.83 3.89 3.93 3.95
Lb/h 156 148 139 129 119 109 97.9
Btu/h 14700 13400 12200 10900 9710 8500 7340
25
30
35
40
45
50
55
Watts 1020 1090 1140 1190 1230 1260 1280 Amps 3.58 3.72 3.84 3.94 4.02 4.09 4.14
Lb/h 180 171 161 151 140 129 117
Btu/h 16800 15500 14100 12700 11400 10000 8730 Watts 1030 1120 1190 1250 1300 1340 1370 Amps 3.61 3.77 3.92 4.04 4.15 4.24 4.32
Lb/h 205 196 186 175 163 151 138
Btu/h 19200 17700 16200 14700 13200 11700 10300 Watts 1050 1150 1230 1310 1370 1420 1460 Amps 3.62 3.81 3.98 4.14 4.28 4.40 4.51
Lb/h 233 223 212 200 188 175 161
Btu/h 21700 20100 18500 16800 15200 13500 11900 Watts 1050 1160 1270 1360 1430 1490 1540 Amps 3.62 3.84 4.04 4.23 4.40 4.55 4.69
Lb/h 262 251 240 227 214 200 186
Btu/h 24400 22600 20900 19100 17300 15500 13800 Watts 1040 1170 1290 1400 1480 1560 1620 Amps 3.61 3.86 4.09 4.31 4.51 4.70 4.88
Lb/h 292 281 269 256 242 228 212
Btu/h 27200 25300 23400 21500 19500 17600 15700 Watts 1010 1170 1310 1430 1530 1620 1690 Amps 3.59 3.87 4.13 4.38 4.62 4.84 5.06
Lb/h 324 313 300 287 272 257 241
Btu/h 30200 28200 26100 24000 21900 19800 17800 Watts 979 1150 1310 1450 1570 1670 1760 Amps 3.55 3.86 4.16 4.44 4.72 4.98 5.23
Lb/h 358 346 333 319 304 288 271
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 9.553639E+03 4.915988E+02 1.912466E+00 9.853188E+01 C2 3.899728E+02 -1.597581E+01 -2.271510E-03 3.678314E+00 C3 1.340239E+00 8.334508E+00 3.053878E-02 1.696019E-01 C4 4.365783E+00 -1.557136E-01 -3.993915E-04 3.855777E-02 C5 -1.669616E+00 3.962326E-01 1.301795E-04 -4.114952E-03 C6 -7.171180E-01 -5.873415E-02 -1.777733E-04 -6.078220E-03 C7 -4.853299E-03 -1.764826E-03 -1.247374E-06 -1.021889E-04 C8 -7.372553E-03 1.831156E-03 3.553077E-06 6.875142E-05 C9 -2.561643E-03 -1.149906E-03 9.675834E-07 -6.677916E-05
C10 2.549114E-03 1.124555E-04 1.883340E-07 1.471979E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature
Loading...