Tecumseh AWG4525WXNKN User Manual

AWG4525WXNKN_Rel
AWG4525WXNKN
Overall Dimensions, inch (mm)
Line connections
Pump down
Air flow
Oil Ch.
Gross weight
L W H
Suction
Liquid
90% @ 90oF
SCFM
Oz.
Lbs. (kg)
26.55 (674)
36.25 (921)
26.08 (662)
7/8"
3/8"
23.26
1500
33.6
300 (136)
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
Ambient Temperatures
80°F
90°F
95°F
100°F
110°F
T, °F
PSIG
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
10
32.8
13400
1850
92
12000
1890
102
11400
1920
107
10700
1940
112
9500
1980
122
15
37.7
15100
1940
93
13700
2000
104
13000
2030
108
12300
2050
113
11000
2110
123
20
43.0
17000
2040
95
15500
2100
105
14800
2140
110
14100
2170
115
12600
2230
125
25
48.8
19100
2130
97
17500
2210
107
16700
2250
112
15900
2290
117
14300
2360
126
30
54.9
21200
2230
99
19500
2320
109
18600
2360
114
17800
2400
118
16100
2490
128
35
61.5
23500
2330
101
21600
2430
111
20700
2470
116
19800
2520
120
17900
2620
130
40
68.5
25800
2420
103
23800
2530
113
22900
2590
118
21900
2640
122
19900
2750
132
45
76.0
28300
2520
106
26200
2640
115
25100
2700
120
24000
2760
125
21900
2880
134
50
84.0
30900
2620
108
28600
2750
118
27500
2820
122
26300
2890
127
24000
3010
136
55
92.6
33700
2710
111
31200
2860
120
29900
2940
125
28700
3010
129
26100
3150
138
R22 Capacity Performance @ 60 Hz, Return Gas Temperature 65oF, --- Sub Cooling 5oF, shown above R407C Capacity performance factor: 0.87 (Multiply the R22 BTU/Hr. by 0.87 to determine the Capacity at R407C)
TPC May 31, 2016
TECUMSEH OUTDOOR
CONDENSING UNIT
Model AWG4525WXNKN BOM 32L2171-4U
Air Cooled 2 HP Application High Temp Refrigerant R22 / R407C Volts-Hz-Ph. 208-230/60/1
AWG4525WXNKN_Rel
Parts/Specifications
Unit BOM
32L2171-4U
Fan Motor
810F050C20
Adjustable Fan Control
----
Unit MODEL
AWG4525WXNKN
Replacement Fan Motor
50W230
Fixed Fan Control
84132-01
Fan Motor Qty
2
Refrigeration Range
20°F to 55°F
Fan Motor RLA
0.7
Defrost Timer
----
Design Pressure Low / High
150 / 450
Fan Blade
51568-1
Electric Defrost Timer
----
Volts - HZ - Ph
208-230V ~ 60HZ
Fan Guard
70831
Voltage Range
187 - 253
Receiver Heater
-----
Min. Circuit Ampacity
16.27
Shroud
70648-2
Receiver Heater Thermostat
-----
Max. Fuse Size
30
Condenser
50858-1
C/Case Heater
91022-1
Compressor MODEL
AWG5524WXN
Receiver
51099-2L
Unit Drawing
DGU1918-L021
Compressor BOM
AW705GT-099-J7
Accumulator
----
Wiring Diagram
WD21-201
Compressor LRA
60
Liquid Filter
70139
Compressor RLA
11.00
Sight Glass
70084-S
Suction Filter
Overload
Internal
Replacement Kit - O/L
----
High Pressure Switch
84095-1L
Relay
8200RVAL94
Low Pressure Control
----
Replacement Kit - Relay
K71-19
Low Pressure Switch
841-10004
Run Capacitor
85PR370F17
Head Master Valve
70083-1
Replacement Kit Run Cap.
K150-14
Check Valve
----
Loose Optional Items
Start Capacitor
85PS330D76
Liquid Valve
On the Receiver
Disconnect Switch
LDSG-613
Replacement Kit Start Cap
K146-13
Suction Valve (Base)
56500-K14
Liquid Solenoid
KSVC-264
Contactor
91017H
Hail Louver
LLPG-201
TPC May 31, 2016
Loading...