Tecumseh AWG4524WXTKN User Manual

AWG4524WXTKN_Rel
AWG4524WXTKN
Overall Dimensions, inch (mm)
Line connections
Pump down
Air flow
Oil Ch.
Gross weight
L W H
Suction
Liquid
90% @ 90oF
SCFM
Oz.
Lbs. (kg)
26.55 (674)
36.25 (921)
26.08 (662)
7/8"
3/8"
22.93
1750
33.86
280 (127)
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
Ambient Temperatures
80°F
90°F
95°F
100°F
110°F
T, °F
PSIG
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
BTUH
Watts
Cond T
10
32.8
13000
1750
97
11400
1860
107
10700
1860
111
10100
1880
116
8900
1900
125
15
37.7
14500
1860
99
13000
1900
109
12300
2000
113
11600
2030
118
10400
2060
127
20
43.0
16200
1970
101
14700
2110
111
13900
2140
116
13200
2170
120
11800
2210
129
25
48.8
17900
2080
103
16400
2230
113
15700
2270
118
14900
2310
123
13400
2360
131
30
54.9
19800
2200
106
18200
2350
116
17400
2410
120
16600
2450
125
15000
2510
134
35
61.5
21800
2310
108
20100
2480
118
19300
2540
123
18400
2590
128
16700
2650
136
40
68.5
23900
2430
112
22100
2600
121
21200
2670
125
20300
2720
130
18400
2790
139
45
76.0
26200
2550
115
24200
2720
124
23200
2790
128
22200
2850
132
20100
2920
141
50
84.0
28500
2670
118
26300
2840
126
25200
2920
131
24100
2970
135
22000
3060
144
55
92.6
31000
2780
122
28500
2960
129
27300
3040
133
26100
3100
138
23900
3190
146
R22 Capacity Performance @ 60 Hz, Return Gas Temperature 65oF, --- Sub Cooling 5oF, shown above R407C Capacity performance factor: 0.87 (Multiply the R22 BTU/Hr. by 0.87 to determine the Capacity at R407C)
TPC April 12, 2016
TECUMSEH OUTDOOR
CONDENSING UNIT
Model AWG4524WXTKN BOM 32L2188-4U
Air Cooled 2 HP Application High Temp Refrigerant R22 / R407C Volts-Hz-Ph. 200-230/60/3
AWG4524WXTKN_Rel
Parts/Specifications
Unit BOM
32L2188-4U
Fan Motor
810F050C20
Adjustable Fan Control
----
Unit MODEL
AWG4524WXTKN
Replacement Fan Motor
50W230
Fixed Fan Control
84132-01
Fan Motor Qty
2
Refrigeration Range
20°F to 55°F
Fan Motor RLA
0.7
Defrost Timer
----
Design Pressure Low / High
150 / 450
Fan Blade
51568-1
Electric Defrost Timer
----
Volts - HZ - Ph
200-230V 3~ 60HZ
Fan Guard
70831
Voltage Range
180 - 253
Receiver Heater
-----
Min. Circuit Ampacity
11.31
Shroud
70648-2
Receiver Heater Thermostat
-----
Max. Fuse Size
20
Condenser
50855-1
C/Case Heater
91022-1
Compressor MODEL
AWG5524WXT
Receiver
51099-2L
Unit Drawing
DGU1918-L021
Compressor BOM
AW705ST-120-J7
Accumulator
----
Wiring Diagram
WD23-201
Compressor LRA
50
Liquid Filter
70139
Compressor RLA
7.76
Sight Glass
70084-S
Suction Filter
----
Overload
Internal
Replacement Kit - O/L
----
High Pressure Switch
84095-1L
Relay
----
Low Pressure Control
----
Replacement Kit - Relay
----
Low Pressure Switch
841-10004
Run Capacitor
----
Head Master Valve
70083-1
Replacement Kit Run Cap.
----
Check Valve
----
Loose Optional Items
Start Capacitor
----
Liquid Valve
On the Receiver
Disconnect Switch
LDSG-332
Replacement Kit Start Cap
----
Suction Valve (Base)
56500-K14
Liquid Solenoid
KSVC-264
Contactor
91014H
Hail Louver
LLPG-201
TPC April 12, 2016
Loading...